diff options
author | Christian Poessinger <christian@poessinger.com> | 2021-06-22 18:34:21 +0200 |
---|---|---|
committer | Christian Poessinger <christian@poessinger.com> | 2021-06-22 18:34:58 +0200 |
commit | 47604c76587cc6cb7742e91940de2f40ad6d7eb0 (patch) | |
tree | 719d4d06886b6c4855e3940781778a33ca4f19d3 /data/mibs/DISMAN-NSLOOKUP-MIB.txt | |
parent | debd7996f89b01fa8d3584efbcda9a5675ee4344 (diff) | |
download | vyos-1x-47604c76587cc6cb7742e91940de2f40ad6d7eb0.tar.gz vyos-1x-47604c76587cc6cb7742e91940de2f40ad6d7eb0.zip |
snmp: T3606: Install MIBs into well known location
FRR also expects the MIBs in /usr/share/snmp/mibs
Diffstat (limited to 'data/mibs/DISMAN-NSLOOKUP-MIB.txt')
-rw-r--r-- | data/mibs/DISMAN-NSLOOKUP-MIB.txt | 509 |
1 files changed, 0 insertions, 509 deletions
diff --git a/data/mibs/DISMAN-NSLOOKUP-MIB.txt b/data/mibs/DISMAN-NSLOOKUP-MIB.txt deleted file mode 100644 index b12ca53dd..000000000 --- a/data/mibs/DISMAN-NSLOOKUP-MIB.txt +++ /dev/null @@ -1,509 +0,0 @@ -DISMAN-NSLOOKUP-MIB DEFINITIONS ::= BEGIN - -IMPORTS - MODULE-IDENTITY, OBJECT-TYPE, - Unsigned32, mib-2, Integer32 - FROM SNMPv2-SMI -- RFC2578 - RowStatus - FROM SNMPv2-TC -- RFC2579 - MODULE-COMPLIANCE, OBJECT-GROUP - FROM SNMPv2-CONF -- RFC2580 - SnmpAdminString - FROM SNMP-FRAMEWORK-MIB -- RFC3411 - InetAddressType, InetAddress - FROM INET-ADDRESS-MIB; -- RFC4001 - - lookupMIB MODULE-IDENTITY - LAST-UPDATED "200606130000Z" -- 13 June 2006 - ORGANIZATION "IETF Distributed Management Working Group" - CONTACT-INFO - "Juergen Quittek - - NEC Europe Ltd. - Network Laboratories - Kurfuersten-Anlage 36 - 69115 Heidelberg - Germany - - Phone: +49 6221 4342-115 - Email: quittek@netlab.nec.de" - DESCRIPTION - "The Lookup MIB (DISMAN-NSLOOKUP-MIB) enables determination - of either the name(s) corresponding to a host address or of - the address(es) associated with a host name at a remote - host. - - Copyright (C) The Internet Society (2006). This version of - this MIB module is part of RFC 4560; see the RFC itself for - full legal notices." - - -- Revision history - - REVISION "200606130000Z" -- 13 June 2006 - DESCRIPTION - "Updated version, published as RFC 4560. - - Replaced references to RFC 2575 by RFC 3415 - - Replaced references to RFC 2571 by RFC 3411 - - Replaced references to RFC 2851 by RFC 4001 - - Added value enabled(1) to SYNTAX clause of - lookupCtlOperStatus - - Added lookupMinimumCompliance - - Defined semantics of value 0 for object - lookupPurgeTime - - Added DEFVAL { unknown } to object - lookupCtlTargetAddressType OBJECT-TYPE" - - REVISION "200009210000Z" -- 21 September 2000 - DESCRIPTION - "Initial version, published as RFC 2925." - ::= { mib-2 82 } - - -- Top level structure of the MIB - - lookupObjects OBJECT IDENTIFIER ::= { lookupMIB 1 } - lookupConformance OBJECT IDENTIFIER ::= { lookupMIB 2 } - - -- Simple Object Definitions - - lookupMaxConcurrentRequests OBJECT-TYPE - SYNTAX Unsigned32 - UNITS "requests" - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The maximum number of concurrent active lookup requests - that are allowed within an agent implementation. A value - of 0 for this object implies that there is no limit for - the number of concurrent active requests in effect. - - The limit applies only to new requests being activated. - When a new value is set, the agent will continue processing - all the requests already active, even if their number - exceed the limit just imposed." - DEFVAL { 10 } - ::= { lookupObjects 1 } - - lookupPurgeTime OBJECT-TYPE - SYNTAX Unsigned32 (0..86400) - UNITS "seconds" - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The amount of time to wait before automatically - deleting an entry in the lookupCtlTable and any - dependent lookupResultsTable entries - after the lookup operation represented by a - lookupCtlEntry has been completed. - A lookupCtEntry is considered complete - when its lookupCtlOperStatus object has a - value of completed(3). - - A value of 0 indicates that automatic deletion - of entries is disabled." - DEFVAL { 900 } -- 15 minutes as default - ::= { lookupObjects 2 } - - -- Lookup Control Table - - lookupCtlTable OBJECT-TYPE - SYNTAX SEQUENCE OF LookupCtlEntry - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Defines the Lookup Control Table for providing - the capability of performing a lookup operation - for a symbolic host name or for a host address - from a remote host." - ::= { lookupObjects 3 } - - lookupCtlEntry OBJECT-TYPE - SYNTAX LookupCtlEntry - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Defines an entry in the lookupCtlTable. A - lookupCtlEntry is initially indexed by - lookupCtlOwnerIndex, which is a type of SnmpAdminString, - a textual convention that allows for the use of the SNMPv3 - View-Based Access Control Model (RFC 3415, VACM) - and that also allows a management application to identify - its entries. The second index element, - lookupCtlOperationName, enables the same - lookupCtlOwnerIndex entity to have multiple outstanding - requests. The value of lookupCtlTargetAddressType - determines which lookup function to perform." - INDEX { - lookupCtlOwnerIndex, - lookupCtlOperationName - } - ::= { lookupCtlTable 1 } - - LookupCtlEntry ::= - SEQUENCE { - lookupCtlOwnerIndex SnmpAdminString, - lookupCtlOperationName SnmpAdminString, - lookupCtlTargetAddressType InetAddressType, - lookupCtlTargetAddress InetAddress, - lookupCtlOperStatus INTEGER, - lookupCtlTime Unsigned32, - lookupCtlRc Integer32, - lookupCtlRowStatus RowStatus - } - - lookupCtlOwnerIndex OBJECT-TYPE - SYNTAX SnmpAdminString (SIZE(0..32)) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "To facilitate the provisioning of access control by a - security administrator using the View-Based Access - Control Model (RFC 2575, VACM) for tables in which - multiple users may need to create or - modify entries independently, the initial index is used as - an 'owner index'. Such an initial index has a syntax of - SnmpAdminString and can thus be trivially mapped to a - - securityName or groupName defined in VACM, in - accordance with a security policy. - - When used in conjunction with such a security policy all - entries in the table belonging to a particular user (or - group) will have the same value for this initial index. - For a given user's entries in a particular table, the - object identifiers for the information in these entries - will have the same subidentifiers (except for the - 'column' subidentifier) up to the end of the encoded - owner index. To configure VACM to permit access to this - portion of the table, one would create - vacmViewTreeFamilyTable entries with the value of - vacmViewTreeFamilySubtree including the owner index - portion, and vacmViewTreeFamilyMask 'wildcarding' the - column subidentifier. More elaborate configurations - are possible." - ::= { lookupCtlEntry 1 } - - lookupCtlOperationName OBJECT-TYPE - SYNTAX SnmpAdminString (SIZE(0..32)) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "The name of a lookup operation. This is locally unique, - within the scope of an lookupCtlOwnerIndex." - ::= { lookupCtlEntry 2 } - - lookupCtlTargetAddressType OBJECT-TYPE - SYNTAX InetAddressType - MAX-ACCESS read-create - STATUS current - DESCRIPTION - "Specifies the type of address for performing a - lookup operation for a symbolic host name or for a host - address from a remote host. - - Specification of dns(16) as the value for this object - means that a function such as, for example, getaddrinfo() - or gethostbyname() should be performed to return one or - more numeric addresses. Use of a value of either ipv4(1) - or ipv6(2) means that a functions such as, for example, - getnameinfo() or gethostbyaddr() should be used to return - the symbolic names associated with a host." - DEFVAL { unknown } - ::= { lookupCtlEntry 3 } - - lookupCtlTargetAddress OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-create - STATUS current - DESCRIPTION - "Specifies the address used for a resolver lookup at a - remote host. The corresponding lookupCtlTargetAddressType - objects determines its type, as well as the function - that can be requested. - - A value for this object MUST be set prior to - transitioning its corresponding lookupCtlEntry to - active(1) via lookupCtlRowStatus." - ::= { lookupCtlEntry 4 } - - lookupCtlOperStatus OBJECT-TYPE - SYNTAX INTEGER { - enabled(1), -- operation is active - notStarted(2), -- operation has not started - completed(3) -- operation is done - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Reflects the operational state of an lookupCtlEntry: - - enabled(1) - Operation is active. - notStarted(2) - Operation has not been enabled. - completed(3) - Operation has been completed. - - An operation is automatically enabled(1) when its - lookupCtlRowStatus object is transitioned to active(1) - status. Until this occurs, lookupCtlOperStatus MUST - report a value of notStarted(2). After the lookup - operation is completed (success or failure), the value - for lookupCtlOperStatus MUST be transitioned to - completed(3)." - ::= { lookupCtlEntry 5 } - - lookupCtlTime OBJECT-TYPE - SYNTAX Unsigned32 - UNITS "milliseconds" - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Reports the number of milliseconds that a lookup - operation required to be completed at a remote host. - Completed means operation failure as well as - - success." - ::= { lookupCtlEntry 6 } - - lookupCtlRc OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The system-specific return code from a lookup - operation. All implementations MUST return a value - of 0 for this object when the remote lookup - operation succeeds. A non-zero value for this - objects indicates failure. It is recommended that - implementations return the error codes that are - generated by the lookup function used." - ::= { lookupCtlEntry 7 } - - lookupCtlRowStatus OBJECT-TYPE - SYNTAX RowStatus - MAX-ACCESS read-create - STATUS current - DESCRIPTION - "This object allows entries to be created and deleted - in the lookupCtlTable. - - A remote lookup operation is started when an - entry in this table is created via an SNMP set - request and the entry is activated. This - occurs by setting the value of this object - to CreateAndGo(4) during row creation or - by setting this object to active(1) after - the row is created. - - A value MUST be specified for lookupCtlTargetAddress - prior to the acceptance of a transition to active(1) state. - A remote lookup operation starts when its entry - first becomes active(1). Transitions in and - out of active(1) state have no effect on the - operational behavior of a remote lookup - operation, with the exception that deletion of - an entry in this table by setting its RowStatus - object to destroy(6) will stop an active - remote lookup operation. - - The operational state of a remote lookup operation - can be determined by examination of its - lookupCtlOperStatus object." - REFERENCE - "See definition of RowStatus in RFC 2579, - 'Textual Conventions for SMIv2.'" - ::= { lookupCtlEntry 8 } - --- Lookup Results Table - - lookupResultsTable OBJECT-TYPE - SYNTAX SEQUENCE OF LookupResultsEntry - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Defines the Lookup Results Table for providing - the capability of determining the results of a - operation at a remote host. - - One or more entries are added to the - lookupResultsTable when a lookup operation, - as reflected by an lookupCtlEntry, is completed - successfully. All entries related to a - successful lookup operation MUST be added - to the lookupResultsTable at the same time - that the associating lookupCtlOperStatus - object is transitioned to completed(2). - - The number of entries added depends on the - results determined for a particular lookup - operation. All entries associated with an - lookupCtlEntry are removed when the - lookupCtlEntry is deleted. - - A remote host can be multi-homed and have more than one IP - address associated with it (returned by lookup function), - or it can have more than one symbolic name (returned - by lookup function). - - A function such as, for example, getnameinfo() or - gethostbyaddr() is called with a host address as its - parameter and is used primarily to determine a symbolic - name to associate with the host address. Entries in the - lookupResultsTable MUST be made for each host name - returned. If the function identifies an 'official host - name,' then this symbolic name MUST be assigned a - lookupResultsIndex of 1. - - A function such as, for example, getaddrinfo() or - gethostbyname() is called with a symbolic host name and is - used primarily to retrieve a host address. The entries - - MUST be stored in the order that they are retrieved from - the lookup function. lookupResultsIndex 1 MUST be - assigned to the first entry." - ::= { lookupObjects 4 } - - lookupResultsEntry OBJECT-TYPE - SYNTAX LookupResultsEntry - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Defines an entry in the lookupResultsTable. The - first two index elements identify the - lookupCtlEntry that a lookupResultsEntry belongs - to. The third index element selects a single - lookup operation result." - INDEX { - lookupCtlOwnerIndex, - lookupCtlOperationName, - lookupResultsIndex - } - ::= { lookupResultsTable 1 } - - LookupResultsEntry ::= - SEQUENCE { - lookupResultsIndex Unsigned32, - lookupResultsAddressType InetAddressType, - lookupResultsAddress InetAddress - } - - lookupResultsIndex OBJECT-TYPE - SYNTAX Unsigned32 (1..'ffffffff'h) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Entries in the lookupResultsTable are created when - the result of a lookup operation is determined. - - Entries MUST be stored in the lookupResultsTable in - the order that they are retrieved. Values assigned - to lookupResultsIndex MUST start at 1 and increase - consecutively." - ::= { lookupResultsEntry 1 } - - lookupResultsAddressType OBJECT-TYPE - SYNTAX InetAddressType - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Indicates the type of result of a remote lookup - operation. A value of unknown(0) implies either that - the operation hasn't been started or that - it has failed." - ::= { lookupResultsEntry 2 } - - lookupResultsAddress OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Reflects a result for a remote lookup operation - as per the value of lookupResultsAddressType. - - The address type (InetAddressType) that relates to - this object is specified by the corresponding value - of lookupResultsAddress." - ::= { lookupResultsEntry 3 } - - -- Conformance information - -- Compliance statements - - lookupCompliances OBJECT IDENTIFIER ::= { lookupConformance 1 } - lookupGroups OBJECT IDENTIFIER ::= { lookupConformance 2 } - - -- Compliance statements - - lookupCompliance MODULE-COMPLIANCE - STATUS current - DESCRIPTION - "The compliance statement for SNMP entities that - fully implement the DISMAN-NSLOOKUP-MIB." - MODULE -- this module - MANDATORY-GROUPS { lookupGroup } - - OBJECT lookupMaxConcurrentRequests - MIN-ACCESS read-only - DESCRIPTION - "The agent is not required to support set - operations to this object." - - OBJECT lookupPurgeTime - MIN-ACCESS read-only - DESCRIPTION - "The agent is not required to support a set - operation to this object." - ::= { lookupCompliances 1 } - - lookupMinimumCompliance MODULE-COMPLIANCE - STATUS current - DESCRIPTION - "The minimum compliance statement for SNMP entities - that implement the minimal subset of the - DISMAN-NSLOOKUP-MIB. Implementors might choose this - subset for small devices with limited resources." - MODULE -- this module - MANDATORY-GROUPS { lookupGroup } - - OBJECT lookupMaxConcurrentRequests - MIN-ACCESS read-only - DESCRIPTION - "The agent is not required to support set - operations to this object." - - OBJECT lookupPurgeTime - MIN-ACCESS read-only - DESCRIPTION - "The agent is not required to support a set - operation to this object." - - OBJECT lookupCtlRowStatus - MIN-ACCESS read-only - DESCRIPTION - "Write access is not required. If write access is - not supported, then at least one entry in the - lookupCtlTable MUST be established already when the SNMP - agent starts offering access to the NSLOOKUP-MIB module. - If, in such a case, only a single entry is offered, then - it is RECOMMENDED that this entry use strings with a - length of 0 for both of its two index objects." - ::= { lookupCompliances 2 } - - -- MIB groupings - - lookupGroup OBJECT-GROUP - OBJECTS { - lookupMaxConcurrentRequests, - lookupPurgeTime, - lookupCtlOperStatus, - lookupCtlTargetAddressType, - lookupCtlTargetAddress, - lookupCtlTime, - lookupCtlRc, - lookupCtlRowStatus, - lookupResultsAddressType, - lookupResultsAddress - } - STATUS current - DESCRIPTION - "The group of objects that constitute the remote - Lookup operation." - ::= { lookupGroups 1 } - -END |