summaryrefslogtreecommitdiff
path: root/src/op_mode/snmp_v3_showcerts.sh
diff options
context:
space:
mode:
authorViacheslav Hletenko <v.gletenko@vyos.io>2022-04-05 11:20:54 +0000
committerViacheslav Hletenko <v.gletenko@vyos.io>2022-04-05 11:20:54 +0000
commitd6e22b28887c7a3f7d2f8b955c2e90bcadaeeeba (patch)
tree93793baa1aaf9a47cc423f4ddaa3a84ef638a114 /src/op_mode/snmp_v3_showcerts.sh
parent806ff50bf1a970d731c2227f9d2cd2342b8a1b4e (diff)
downloadvyos-1x-d6e22b28887c7a3f7d2f8b955c2e90bcadaeeeba.tar.gz
vyos-1x-d6e22b28887c7a3f7d2f8b955c2e90bcadaeeeba.zip
interfaces: T4331: Fix assign link-local static IPv6 addr to vrf
If we have link-local static address and vrf, for example: set interfaces ethernet eth2 address 'fe80::5200:ff:fe55:222/64' set interfaces ethernet eth2 vrf 'foo' This IPv6 address was assigned before vrf, as result after attaching the intreface to vrf we lose this static linklocal address DEBUG/IFCONFIG cmd 'ip addr add fe80::5200:ff:fe55:222/64 dev eth2' DEBUG/IFCONFIG cmd 'ip link set dev eth2 master foo' DEBUG/IFCONFIG cmd 'ip addr add fe80::5208:ff:fe13:2/64 dev eth2' This commit fixes this, the address is assigned after vrf assign
Diffstat (limited to 'src/op_mode/snmp_v3_showcerts.sh')
0 files changed, 0 insertions, 0 deletions