Age | Commit message (Collapse) | Author | |
---|---|---|---|
2020-06-19 | router-advert: T2618: fix for wrongly converted "autonomous-flag" | Christian Poessinger | |
Boolean nodes have been removed b/c a boolean value makes less sense. The same behavior can be achieved with the presence or absence of a node. Unfortunately the 'autonomous-flag' node has been a negated one which did not migrate it to 'no-autonomous-flag' if it was set to false previously. | |||
2020-06-19 | dhcpv6-pd: T421: fix unknown lvalue 'StartLimitIntervalSec' warning | Christian Poessinger | |
StartLimitIntervalSec is part of the [Unit] definition and not the [Service] definition [1]. This caused the following warning message: systemd[1]: /lib/systemd/system/dhcp6c@.service:12: Unknown lvalue 'StartLimitIntervalSec' in section 'Service', ignoring This error has been introduced via commit 992d356 ("dhcpv6-pd: T421: workaround for non existing interfaces"). [1]: https://www.freedesktop.org/software/systemd/man/systemd.unit.html | |||
2020-06-19 | pseudo-ethernet: T2589: fix for deleting interface(s) | Christian Poessinger | |
When deleting a peth interface the interface name was not added to the configuration dict, which lead to referencing non existent keys. | |||
2020-06-19 | Merge branch 'console-server' of github.com:c-po/vyos-1x into current | Christian Poessinger | |
* 'console-server' of github.com:c-po/vyos-1x: console-server: T2490: set service priority to 990 op-mode: console-server: T2490: rename "connect console-server" to "connect console" console-server: T2490: server must listen only on localhost op-mode: add "show ip ports" to list local opened ports console-server: T2490: add SSH support for direct device access op-mode: console-server: T2490: get connection info console-server: T2490: remove superfluous "port" node from XML definition console-server: T2490: rename CLI to console-server console-server: T2490: add SSH support console-server: T2490: log to journald console-server: T2490: move CLI parsing to get_config_dict() console-server: T2490: replace ser2net with conserver op-mode: T2490: add "connect serial-proxy" CLI command console-server: T2490: add default CLI values console-server: T2490: rename CLI to "serial-proxy" console-server: T2490: use new USB ports "by-bus" console-server: T2490: use "ls" for completion helper console-server: T2490: initial support | |||
2020-06-19 | console-server: T2490: set service priority to 990 | Christian Poessinger | |
... to ensure the service is started very late. | |||
2020-06-19 | op-mode: console-server: T2490: rename "connect console-server" to "connect ↵ | Christian Poessinger | |
console" | |||
2020-06-19 | console-server: T2490: server must listen only on localhost | Christian Poessinger | |
2020-06-19 | op-mode: add "show ip ports" to list local opened ports | Christian Poessinger | |
2020-06-19 | console-server: T2490: add SSH support for direct device access | Christian Poessinger | |
2020-06-19 | op-mode: console-server: T2490: get connection info | Christian Poessinger | |
2020-06-19 | console-server: T2490: remove superfluous "port" node from XML definition | Christian Poessinger | |
2020-06-19 | op-mode: T2617: rewrite vyatta-op-quagga to XML | Viacheslav Hletenko | |
2020-06-18 | console-server: T2490: rename CLI to console-server | Christian Poessinger | |
2020-06-18 | console-server: T2490: add SSH support | Christian Poessinger | |
A user can define a port under the SSH node per device. WHen connecting to that port and authenticating using regular credentials we will immediately drop to the serial console. This is the same as executing "connect serial-proxy <name>". | |||
2020-06-18 | console-server: T2490: log to journald | Christian Poessinger | |
2020-06-18 | console-server: T2490: move CLI parsing to get_config_dict() | Christian Poessinger | |
For more examples on the new get_config_dict() approach migrate this implementation as it is not yet in production use. Also this serves as proof of concept code for further migrations. | |||
2020-06-18 | console-server: T2490: replace ser2net with conserver | Christian Poessinger | |
2020-06-18 | op-mode: T2490: add "connect serial-proxy" CLI command | Christian Poessinger | |
Used to connecte to a device exposed via serial proxy. | |||
2020-06-18 | console-server: T2490: add default CLI values | Christian Poessinger | |
2020-06-18 | console-server: T2490: rename CLI to "serial-proxy" | Christian Poessinger | |
2020-06-18 | console-server: T2490: use new USB ports "by-bus" | Christian Poessinger | |
2020-06-18 | console-server: T2490: use "ls" for completion helper | Christian Poessinger | |
Using "ls" is much faster compared to "find ... -exec basename" | |||
2020-06-18 | console-server: T2490: initial support | Christian Poessinger | |
2020-06-18 | T2614: add a key mangling option to vyos.config.get_config_dict() | Daniil Baturin | |
2020-06-18 | vyos: configdict: add dict_merge function | Christian Poessinger | |
Merge two dictionaries. Only keys which are not present in destination will be copied from source, anything else will be kept untouched. Function will return a new dict which has the merged key/value pairs. Before: {'device': {'usb0b2.4p1.0': {'speed': '9600'}, 'usb0b2.4p1.1': {'data-bits': '8', 'parity': 'none', 'speed': '115200', 'stop-bits': '2'}}} After: {'device': {'usb0b2.4p1.0': {'data-bits': '8', 'parity': 'none', 'speed': '9600', 'stop-bits': '1'}, 'usb0b2.4p1.1': {'data-bits': '8', 'parity': 'none', 'speed': '115200', 'stop-bits': '2'}}} | |||
2020-06-17 | router-advert: T2609: remove debug pprint statement | Christian Poessinger | |
2020-06-17 | router-advert: T2185: migrate from SysVinit to systemd | Christian Poessinger | |
2020-06-17 | router-advert: T2609: add missing verify() for prefix lifetime | Christian Poessinger | |
radvd[31898]: AdvValidLifeTime must be greater than AdvPreferredLifetime in radvd.conf, line 19 This happens with the following configuration: vyos@vyos# show service router-advert interface eth0.20 { name-server 2001:4860:4860::8888 prefix ::/64 { valid-lifetime 7200 } } A validator is added to solve this issue and radvd will run again. | |||
2020-06-18 | Merge pull request #464 from DmitriyEshenko/cur-1x-17062020 | Daniil Baturin | |
login: radius: T2299: Move RADIUS priority XML definitions to system-… | |||
2020-06-17 | login: radius: T2299: Move RADIUS priority XML definitions to system-login.xml | DmitriyEshenko | |
2020-06-18 | Merge pull request #463 from stside/T2610_fix_router_lifetime | Daniil Baturin | |
T2610: default-lifetime is not reflected in the RA message | |||
2020-06-18 | T2610: fix default-lifetime typo | Shohei YOKOKAWA | |
2020-06-17 | Merge pull request #462 from DmitriyEshenko/cur-1x-17062020 | Christian Poessinger | |
login: radius: T2299: Implement RADIUS servers priority | |||
2020-06-17 | login: radius: T2299: Implement RADIUS servers priority | DmitriyEshenko | |
2020-06-16 | Merge pull request #459 from DmitriyEshenko/1x-ppp-16062020 | Christian Poessinger | |
pppoe-server: T2601: Add default CCP values if not defined via CLI | |||
2020-06-16 | Merge pull request #460 from DmitriyEshenko/1xl2tp16062020 | Christian Poessinger | |
l2tp: T2602: Delete excess characters | |||
2020-06-16 | snmp: T2321: use restart of start in systemctl | Christian Poessinger | |
For an unknown reason snmpd not always starts after reboot. | |||
2020-06-16 | config: T2568: add missing error checking | John Estabrook | |
2020-06-16 | syslog: T2604: remove unnecessary use of is_tag | John Estabrook | |
2020-06-16 | l2tp: T2602: Delete excess characters | DmitriyEshenko | |
2020-06-16 | pppoe-server: T2601: Add default CCP values if not defined via CLI | DmitriyEshenko | |
2020-06-15 | Merge pull request #458 from thomas-mangin/T2599 | Christian Poessinger | |
ifconfig: T2599: fix regex for search, smaller numbers | |||
2020-06-15 | ifconfig: T2599: fix regex for search, smaller numbers | Thomas Mangin | |
2020-06-15 | Merge pull request #457 from thomas-mangin/T2599 | Christian Poessinger | |
ifconfig: T2599: sort interface by natural order | |||
2020-06-15 | ifconfig: T2599: sort interface by natural order | Thomas Mangin | |
2020-06-15 | login: radius: T2600: fix wrongly redered pam_radius_auth.conf | Christian Poessinger | |
When multiple RADIUS servers have been configured, they have been all rendered onto a single line in the config. This lead to errors in syslog and not all servers beeing reachable. | |||
2020-06-15 | Merge pull request #456 from thomas-mangin/T2576 | Christian Poessinger | |
vti: T2576: show interfaces missed VTI | |||
2020-06-15 | vti: T2576: show interfaces missed VTI | Thomas Mangin | |
2020-06-14 | wireless: T2354: add new validator for phy interfaces | Christian Poessinger | |
2020-06-14 | nat: T2593: fix for SNAT translation port when using masquerade | Christian Poessinger | |
The "to" qualifier did not get rendered when using source ports in masquerade targets. This case was totally missed out when porting. |