Age | Commit message (Collapse) | Author |
|
|
|
Replaced CLI commands with API calls.
CLI commands still can be used via:
```
vpp_control = VPPControl()
vpp_control.cli_cmd('command_here')
```
|
|
Add initial configuration mode for VPP (PoC)
set vpp cpu corelist-workers '2'
set vpp cpu main-core '1'
set vpp interface eth1 num-rx-desc '256'
set vpp interface eth1 num-rx-queues '512'
set vpp interface eth1 num-tx-desc '256'
set vpp interface eth1 num-tx-queues '512'
set vpp interface eth1 pci '0000:02:00.0'
set vpp interface eth1 rx-mode 'polling'
set vpp interface eth2 pci '0000:08:00.0'
Limitation:
- 'set vpp interface ethX pci auto' works only per first
commit, then interface detached from default stack and creates
tun interface 'ethX' to communicate with default stack. In this
case we can't get PCI address via ethtool for 'tun' interfaces.
But we can set pci address manualy.
- Interface sync between default stack and VPP-DPDK stack
After vpp change it doesn't trigger iproute2 for changes
(should be written later)
I.e. if we change something in vpp per each commit it restarts
vpp.service it gets empty interface config as we don't configure vpp
directly and it should be configured via iproute2
But then if we do any change on interface (for example description)
it gets IP address, MTU, state, etc.
|
|
vyos.util: T5300: check_port_availability should return False only on EADDRINUSE
|
|
|
|
At boot, the util function check_port_availability can return False with
EADDRNOTAVAIL if the interface is not yet up; check explicitly for
address in use.
|
|
T5303: Rsyslog.service is not working
|
|
warning: ~ action is deprecated, consider using the 'stop' statement instead [v8.24.0 try http://www.rsyslog.com/e/2307 ]
|
|
T5071: QoS add class match DSCP value
|
|
QoS DSCP match is skipped
Add it
set qos policy shaper test class 23 match 10 ip dscp 'network'
tc filter replace dev eth0 parent 1: protocol all u32 match ip dsfield 224 0xff flowid 1:17
|
|
T5296: Fix QoS class bandwidth calculation for auto and percent
|
|
T5256: T5195: Fix QoS match protocol and add vyos.utils.network
|
|
tc filter exepcts protocol number for match instead of protocol name
|
|
|
|
There are wrong bandwidth calculations for the class
We shouldn't rely on interface speed but we should get this value
from 'shaper <tag> bandwidth xxx' if configured 'auto' or
bandwidth with '%'
Otherwise we can get unexpected rate for the class
% sudo cat /sys/class/net/eth0/speed
% -1
generated rate:
classid 1:17 htb rate -1000000
Fix this
|
|
config-mgmt: T5297: add check for changes under node between revisions
|
|
T5295: Fix QoS shaper rate limit
|
|
|
|
Do not handle rate via 'tc filter' directly but rather set the
'tc filter' to direct traffic to the correct tc class flow.
As it in 1.3.
It fixes random unexpected shapes, when you set for example 300mbit
but get 3-11mbit
Current implementation seems not correct as it uses rate limits
two times (in class and in filter):
tc class replace dev eth0 parent 1:1 classid 1:17 htb rate 250000000 \
burst 15k quantum 1514
tc filter replace dev eth0 parent 1: protocol all u32 match \
ip dst 192.168.122.11 action police rate 250000000 burst 15k flowid 1:17
The correct way after fix:
tc class replace dev eth0 parent 1:1 classid 1:17 htb rate 250000000 \
burst 15k quantum 1514
tc filter replace dev eth0 parent 1: protocol all u32 match \
ip dst 192.168.122.11 flowid 1:17
|
|
configsession: T5248: load_section should not set path if dict empty
|
|
|
|
|
|
T5290: Failing commits for SR-IOV interfaces using ixgbevf driver due…
|
|
change speed/duplex settings
This is the same problem as reported in T4297. By definition it is not possible to change speed and duplex settings at SR-IOV virtual functions driven by ixgbevf driver. I think the solution is the same as well, that is to add 'ixgbevf' into _drivers_without_speed_duplex_flow in /usr/lib/python3/dist-packages/vyos/ethtool.py. It fixed the problem for me with Intel x520 NICs.
|
|
http-api: T5248: set/load config sections as JSON via API
|
|
T5283: ipoe-server: add more flexibility in subnet parameter.
|
|
|
|
... this is a step towards a new and better implementation that will utilize
VPP.
|
|
T5282: remove systemd management directive for frr.service
|
|
|
|
frr.service startup and shutdown is now explicitly managed by
vyos-router, so remove the systemd management directive.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T5231: Add op-mode for show reverse-proxy
|
|
T3472: Print warning when commit-confirm is run as regular user
|
|
dns: T5144: Improve dynamic dns monitor and log and miscellaneous updates
|
|
|
|
- For option 'web', ddclient defaults to 'dyndns' which doesn't support
ssl. This results ddclient process lockup till connection to
checkip.dyndns.org:443 times out.
- For option 'use', ddclient defaults 'ip'. This results in confusing
message "WARNING: '' is not a valid IPv4 or IPv6 address" in log.
|
|
|
|
This should make the help messages more consistent for DNS related
CLI subtree.
|
|
Add support for monitoring dynamic dns updates via journalctl.
Additionally, switch to using journalctl to show dynamic dns updates.
Also add/adjust the CLI help messages for consistency.
|
|
'PIDFile' option in 'Service' isn't multi-value and thus doesn't need
to be cleared before overriding.
|
|
|