Age | Commit message (Collapse) | Author |
|
Removing a member from a bond/LACP will turn the physical interface always in
admin-down state. This is invalid, the interface should be placed into the state
configured on the VyOS CLI.
Smoketest on bond interfaces is extended to check this behavior.
|
|
Specifies the minimum number of links that must be active before asserting
carrier. It is similar to the Cisco EtherChannel min-links feature. This allows
setting the minimum number of member ports that must be up (link-up state)
before marking the bond device as up (carrier on). This is useful for situations
where higher level services such as clustering want to ensure a minimum number
of low bandwidth links are active before switchover.
This option only affects 802.3ad mode.
The default value is 0. This will cause carrier to be asserted (for 802.3ad
mode) whenever there is an active aggregator, regardless of the number of
available links in that aggregator. Note that, because an aggregator cannot be
active without at least one available link, setting this option to 0 or to 1
has the exact same effect.
|
|
|
|
Commit 29dd5079 ("ifconfig: T2653: remove duplicated code for address flush")
used the class method for address flushing, but it was cvalled in the wrong way.
|
|
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
|
|
The Interface get_state/set_state were not clear about
if they edited the admin or operational state.
functions are now using admin_state and oper_state
for clarity.
|
|
|
|
|
|
__init__ should be added to a derived class only if it does work in the ctor.
|
|
|
|
|