Age | Commit message (Collapse) | Author |
|
|
|
|
|
T5249: Add rollback-soft feature
|
|
* Move Kea socket permission change on-demand and speed up conf scripts
* Fix issue with DHCP reservations when no `ip-address` value
|
|
The current implementation is wrong as it searches `master` in the
iproute2 JSON output. It is a worng as it could include bridges
or bonding interfaces
Add the more strict search `info_slave_kind == vrf`
|
|
|
|
|
|
image-tools: T5806: clear previous raid configs on install
|
|
|
|
|
|
|
|
|
|
Add the ability to rollback configs without rebooting
```
sudo /usr/bin/config-mgmt rollback_soft --rev 1
rollback-soft 1
```
|
|
Collect in a module several versions of a 'load config' function.
They have different use cases according to performance and error
reporting, and allow comparison of non-legacy and legacy variants.
|
|
|
|
T5812: Fix for rollback check max revision number
|
|
dhcp: T3316: Migrate dhcp/dhcpv6 server to Kea
|
|
|
|
op-cmd: T5802: bug fix for "ping x.x.x.x interface" completion options
|
|
|
|
|
|
|
|
|
|
T5775: firewall: re-add state-policy to firewall. These commands are …
|
|
Restore scanning previous installations for config data and ssh host
keys on install.
|
|
T5779: conntrack: Apply fixes to <set system conntrack timeout custom>
|
|
Remove what was not working on 1.3, migrate what was working to new syntax and extend feature for ipv6.
|
|
accel-ppp: T5688: Standardized pool configuration in accel-ppp
|
|
Standardized pool configuration for all accel-ppp services.
1. Only named pools are used now.
2. Allows all services to use range in x.x.x.x/mask
and x.x.x.x-x.x.x.y format
3. next-pool can be used in all services
2. Allows to use in ipoe gw-ip-address without pool configuration
which allows to use Fraimed-IP-Address attribute by radius.
3. Default pool name should be explicidly configured
with default-pool.
4. In ipoe netmask and range subnet can be different.
|
|
http-api: T5782: use single config-mode script for https and http-api
|
|
|
|
|
|
The iproute2 master argument is used for both a VRF and a bridge device. Using
this in the VRF context would retrieve and report back the wrong interfaces:
Old implementation:
===================
>>> from vyos.utils.network import get_vrf_members
>>> get_vrf_members('br1')
['eth1', 'eth2', 'vxlan1']
>>> get_vrf_members('black')
['br1.3002', 'br1.4000', 'pim6reg10200']
The new implementation:
=======================
>>> from vyos.utils.network import get_vrf_members
>>> get_vrf_members('br1')
[]
>>> get_vrf_members('black')
['br1.3002', 'br1.4000', 'pim6reg10200']
|
|
image-tools: T4516: exit grub-update service if running in docker
|
|
|
|
|
|
|
|
included in <set firewall global-options state-policy> node.
|
|
|
|
T5637: firewall: extend rule for default-action to firewall bridge
|
|
to be able to catch logs using separte rule for default-action
|
|
vxlan: T5753: add support for VNI filtering
|
|
http: T5762: rename "virtual-host listen-port" -> "virtual-host port"
|
|
T5770 Enable MACsec encryption stanza
|
|
|
|
This complements commit f5e43b136 ("http: T5762: api: make API socket backend
communication the one and only default") so we have a consistent port CLI node
across VyOS components.
|
|
Add ability to reboot and poweroff the system via API
curl -k --location --request POST 'https://vyos/reboot' \
--form data='{"op": "reboot", "path": ["now"]}' \
--form key='apikey'
curl -k --location --request POST 'https://vyos/poweroff' \
--form data='{"op": "poweroff", "path": ["now"]}' \
--form key='apikey'
|
|
T2405: add Git support to commit-archive
|
|
In a service provider network a service provider typically supports multiple
bridge domains with overlapping vlans. One bridge domain per customer. Vlans in
each bridge domain are mapped to globally unique VXLAN VNI ranges assigned to
each customer.
Without the ability of VNI filtering, we can not provide VXLAN tunnels
with multiple tenants all requiring e.g. VLAN 10.
To Test:
set interfaces vxlan vxlan987 parameters external
set interfaces vxlan vxlan987 source-interface eth0
set interfaces vxlan vxlan987 parameters vni-filter
set interfaces vxlan vxlan987 vlan-to-vni 50 vni 10050
set interfaces vxlan vxlan987 vlan-to-vni 51 vni 10051
set interfaces vxlan vxlan987 vlan-to-vni 52 vni 10052
set interfaces vxlan vxlan987 vlan-to-vni 53 vni 10053
set interfaces vxlan vxlan987 vlan-to-vni 54 vni 10054
set interfaces vxlan vxlan987 vlan-to-vni 60 vni 10060
set interfaces vxlan vxlan987 vlan-to-vni 69 vni 10069
set interfaces bridge br0 member interface vxlan987
Add new op-mode command: show bridge vni
Interface VNI
----------- -----------
vxlan987 10050-10054
vxlan987 10060
vxlan987 10069
|
|
image: T4516: Added system image tools
|