summaryrefslogtreecommitdiff
path: root/src/conf_mode
AgeCommit message (Collapse)Author
2023-03-27dns: T5113: Support custom port for name-server forwardersIndrajit Raychaudhuri
Support custom port for name-server forwarders that would allow using custom ports in name server forwarders to enable forwarding to alternative name servers (unbound, stubby, dnscrypt-proxy etc.) operating on non-default port. This would also allow using DNS Over TLS in PowerDNS Recursor 4.6 onwards (pdns doesn't support certificate check for validity yet) by enabling 'dot-to-port-853'. This is set by default if compiled in with DoT support. See: https://doc.powerdns.com/recursor/settings.html#dot-to-port-853 This also partially implements T921, T2195 (DoT without certificate check). Implementation details: - In 'dns/forwarding' configuration, 'name-server' now allows optional 'port' (defaults to 53). - Instead of modifying 'name-server-ipv4-ipv6.xml.i' to add optional 'port', a new file 'name-server-ipv4-ipv6-port.xml.i' has been used to avoid impacting other places where it is reused because not all of them honor ports (mostly VPN related). - The `host:port` entries to be used by PowerDNS recursor config are normalized eagerly at the point of loading VyOS `Config` instead of doing them lazily while rendering the Jinja2 template to keep the implementation less intrusive. The alternative would entail making quite a bit of change in how 'vyos-hostsd' processes 'static' 'name_servers' entries or persists their runtime states.
2023-03-23Merge pull request #1901 from sever-sever/T5099Christian Breunig
T5099: IPoE-server add option next-pool for named ip pools
2023-03-23ipsec: T2816: Cleanup dhcp hook file if not requiredsarthurdev
2023-03-22T5105: Fix error message from dhcp-serverNicolas Fort
2023-03-21ospf: T5102: do not always redistribute babel routesChristian Breunig
2023-03-21T5099: IPoE-server add option next-pool for named ip poolsViacheslav Hletenko
In cases with multiple named IP pools, it is required the option 'next' to be sure that if IP addresses ended in one pool, then they would begin to be allocated from the next named pool. For accel-ppp it requires specific order as pool must be defined before we can use it with the 'next-option' set service ipoe-server client-ip-pool name first-pool subnet '192.0.2.0/25' set service ipoe-server client-ip-pool name first-pool next-pool 'second-pool' set service ipoe-server client-ip-pool name second-pool subnet '203.0.113.0/25' [ip-pool] 203.0.113.0/25,name=second-pool 192.0.2.0/25,name=first-pool,next=second-pool
2023-03-21Merge pull request #1889 from nicolas-fort/T5050-logViacheslav Hletenko
T5050: Firewall: Add log options
2023-03-21T5050: Firewall: Add log optionsNicolas Fort
2023-03-17T5086: Fix sflow fix default values for serverViacheslav Hletenko
We drop default values 'port' but don't set it again per server Fix it
2023-03-16Merge pull request #1895 from sever-sever/T5091Christian Breunig
T5091: IPoE-server verify RADIUS settings
2023-03-16T5091: IPoE-server verify RADIUS settingsViacheslav Hletenko
As we don't have global option 'gateway-address' for ipoe-server we cannot use general configverify.verify_accel_ppp_base_service Add verify radius setting for configuration mode 'radius' Radius authentication required at least one RADIUS server
2023-03-16T5086: Add sFlow feature based on hsflowdViacheslav Hletenko
Add sFlow feature based on hsflowd According to user reviews, it works more stable and more productive than pmacct I haven't deleted 'pmacct' 'system flow-accounting sflow' yet It could be migrated or deprecated later set system sflow agent-address '192.0.2.14' set system sflow interface 'eth0' set system sflow interface 'eth1' set system sflow polling '30' set system sflow sampling-rate '100' set system sflow server 192.0.2.1 port '6343' set system sflow server 192.0.2.11 port '6343'
2023-03-14T5085: Fix ipv6 route-map for ospfv3Viacheslav Hletenko
Add template to generate zebra "ipv6 protocol ospf6 route-map xxx"
2023-03-10container: T4959: add registry authentication optionChristian Breunig
Container registry CLI node changed from leafNode to tagNode with the same defaults. In addition we can now configure an authentication option per registry.
2023-03-09qos: T5018: Use configdep to fix interface mirror/redirect issuesarthurdev
This will check if mirror/redirect is present on a QoS interface and use `vyos.configdep` module to update the interface again after QoS is applied.
2023-03-09T5063: IPoE-server ethX vlan must not be used with client-subnetViacheslav Hletenko
IPoE-server 'interface ethX vlan xxx' (aka vlan-mon) must not be used with 'interface ethX client-subnet' So instead of shared pool accel-ppp uses the same pool for each dynamically added VLAN eth1 client-subnet '192.0.2.0/24' eth1 vlan '2000-2021' It cause this issue: eth1.2000 range 192.0.2.0/24 (the first client gets address from 192.0.2.2) eth2.2001 range 192.0.2.0/24 (the first client gets address from 192.0.2.2) Only named pools with vlan option must be used.
2023-03-08T5066: Fix GRE tunnel variable name which checks keysViacheslav Hletenko
2023-03-02login: T5039: catch error on 'my_set' for auth plaintext-passwordJohn Estabrook
2023-02-28Merge pull request #1857 from nicolas-fort/nft_queueChristian Breunig
T5037: Firewall: Add queue action and options to firewall
2023-02-28T4967: Allow setting container hostnameViacheslav Hletenko
Ability setting container hostname This host name is used as /etc/hostname set container name <tag> host-name 'mybox'
2023-02-28T5037: Firewall: Add queue action and options to firewallNicolas Fort
2023-02-28Merge pull request #1800 from vfreex/feature-babelChristian Breunig
T4977: Add Babel routing protocol support
2023-02-28Merge pull request #1784 from Zen3515/current-add-container-command-argChristian Breunig
container: T4014: Add `command`, `arg` and `entrypoint` configuration options for containers
2023-02-27openconnect: T4955: Renamed function and changed error messagesaapostoliuk
Renamed local function to be identical to 1.3 ver Changed error messages after commit to be identical to 1.3 ver
2023-02-27Merge pull request #1644 from aapostoliuk/T4790-sagittaViacheslav Hletenko
T4790: Added check of the sum of radius timeouts
2023-02-25python: T5026: Replace deprecated Python modules crypt, spwdsarthurdev
DeprecationWarning: 'crypt' is deprecated and slated for removal in Python 3.13 DeprecationWarning: 'spwd' is deprecated and slated for removal in Python 3.13
2023-02-24login: T1948: drop absolut path to /usr/libexec/vyos, re-use vyos.defaultsChristian Breunig
2023-02-24http-api: T5030: fix missing check on delete keys id tag or key valueJohn Estabrook
2023-02-22openconnect: T5023: Conf script missing optional config parametersarthurdev
2023-02-22Merge pull request #1839 from sarthurdev/ipsecChristian Breunig
ipsec: T4593: Remove references to deleted variables
2023-02-22ipsec: T4593: Remove references to deleted variablessarthurdev
2023-02-21T4978: Default values of port rewrite default container valuesViacheslav Hletenko
As we have the same variable name 'default_values' for container name, port and volume, it rewrites default container parameters with default port parameters Fix it
2023-02-15ipsec: T4593: Migrate and remove legacy `include-ipsec` nodessarthurdev
Not supported with swanctl
2023-02-14strongSwan: T4593: move to charon-systemdChristian Breunig
2023-02-12T5001: Replace links to the phabricator siteChristian Breunig
Replace links to the phabricator site from https://phabricator.vyos.net to https://vyos.dev
2023-02-10Merge pull request #1805 from nicolas-fort/T4857-frr-fixChristian Breunig
T4857: snmp: Fix error when not defining client|network under community
2023-02-10snmp: T4857: explicitly define default community networks 0.0.0.0/0 and ::/0Christian Breunig
After the RESTRICTED view was introduced snmpd requires a network to be specified. Before adding the RESTRICTED view snmpd always assumed the default network 0.0.0.0/0. This commit re-adds the build in default networks for IPv4 and IPv6 and exposes it as a proper default to the CLI so the user is informed about it: vyos@vyos# set service snmp community foooo Possible completions: authorization Authorization type (default: ro) + client IP address of SNMP client allowed to contact system + network Subnet of SNMP client(s) allowed to contact system (default: 0.0.0.0/0, ::/0)
2023-02-10interfaces: T4995: rename user -> username CLI node for pppoe, wwan and ↵Christian Breunig
sstp-client
2023-02-09Revert "container: T4959: Add container registry authentication config for ↵Christian Breunig
containers" This reverts commit b17251334c57c2f6875c19ad4e6c6127aa9e1811.
2023-02-09Merge pull request #1790 from Zen3515/current-add-container-loginChristian Breunig
container: T4959: Add container registry authentication config for containers
2023-02-08T4977: Add Babel routing protocol supportYuxiang Zhu
This PR adds basic Babel routing protocol support using the implementation in FRR. Signed-off-by: Yuxiang Zhu <vfreex@gmail.com>
2023-02-04dhcp-relay: T2408: use Warning() on deprecated interface CLI nodeChristian Breunig
2023-02-04Merge pull request #1603 from nicolas-fort/T2408Christian Breunig
T2408: dhcp-relay: Add listen-interface and upstream-interface feature
2023-02-04qos: T4284: add safeguard for non existing interfacesChristian Breunig
When shaper is bound to a dialup (e.g. PPPoE) interface it is possible, that it is yet not availbale when to QoS code runs. Skip the configuration and inform the user.
2023-02-04Merge pull request #1797 from ServerForge/currentChristian Breunig
bgp: T4817: add support for RFC9234
2023-02-04Revert "login: T4975: Fixed broken CLI commands"Christian Breunig
This reverts commit 3a6e77d479da4321b851163490a9b79ef2cef7b8. A general solution is implemented in Commit 29a44a73 ("T4975: always sync() filesystem after commit").
2023-02-04T4817 added support for RFC 9234Kyle McClammy
2023-02-02login: T4975: Fixed broken CLI commandszsdc
User profile files are not saved to disk after configuration is fully applied. Because of this, after a fast system reset, profile files can be empty, and CLI is broken. This fix adds a `sync()` call after the user's configuration, which should protect from data loss and fix the problem with profiles.
2023-01-31container: T4014: Add `command`, `arg` and `entrypoint` configuration ↵Zen3515
options for containers
2023-01-30container: T4959: Add container registry authentication config for containersZen3515