Age | Commit message (Collapse) | Author |
|
Despite the fact that running verify on Config() is "bad" and "not as intended"
the level of the configuration must match the keys that are checked by exits().
Re-set proper Config() level before querying the system nodes.
|
|
... an error would be presented: jinja2.exceptions.TemplateSyntaxError:
expected token 'end of statement block', got 'mhz_incapable', thus we simply
rename the key before rendering the template.
|
|
Removing a member from a bond/LACP will turn the physical interface always in
admin-down state. This is invalid, the interface should be placed into the state
configured on the VyOS CLI.
Smoketest on bond interfaces is extended to check this behavior.
|
|
|
|
|
|
|
|
|
|
|
|
Now that b40c52682a256 ("config: T2636: get_config_dict() returns a list on
multi node by default") is implemented the workarounds can be removed.
|
|
|
|
Depending on the underlaying Kernel version load the corresponding Kernel
module.
|
|
rip: T2833: Fix distribute-list filter
|
|
|
|
|
|
|
|
The current CLI did not support multiple prefix-delegations per interface. Some
ISPs only send one /64 to a client per prefix-delegation request, but they
allow the customer to request multiple prefixes.
The 'dhcpv6-options prefix-delegation' node has been renamed and converted to a
tag node named 'dhcpv6-options pd'. The tag node specifies a PD request (>=0).
In the past the user needed to know what prefix will be assigned and required
to calculate the sla-len by himself. The 'sla-len' node was dropped and is now
calculated in the background from the 'dhcpv6-options pd 0 length' node.
It is no longer mandatory to supply the 'sla-id' node, if sla-id is not
specified it is 'guessed' by counting upwards.
Example configuration:
----------------------
ethernet eth1 {
address dhcpv6
dhcpv6-options {
pd 0 {
length 56
interface eth2 {
address 1
}
}
}
}
This will request a /56 assignment from the ISP and will delegate a /64 network
to interface eth2. VyOS will use the interface address ::1 on the delegate
interface (eth2) as its local address.
|
|
|
|
|
|
anyconnect: T2811: Return None if anyconnect not configured
|
|
|
|
|
|
|
|
|
|
* 't2564-lcd' of github.com:c-po/vyos-1x:
lcd: T2564: flatten CLI interface
system display: T2564: Added test model
system display: T2564: Dictionary code update
system display: T2564: Conf files to /run
system display: T2564: Changed "duration" to "time"
system display: T2564: py code cleanup
system display: T2564: Replace "config (enabled|disabled)" with "display disabled"
system display: T2564: Lowercase model names
system display: T2564 Extend VyOS to support appliance LCDs
|
|
|
|
Add missing verify() check that at least one interface must be defined to
listen to PPPoE data.
|
|
* set system lcd device <device>
* set system lcd model <modeml>
Both device and model have completion helpers for supported interfaces and LCD
displays.
|
|
|
|
t2564-lcd
* 'system-display' of https://github.com/fmertz/vyos-1x:
system display: T2564: Added test model
system display: T2564: Dictionary code update
system display: T2564: Conf files to /run
system display: T2564: Changed "duration" to "time"
system display: T2564: py code cleanup
system display: T2564: Replace "config (enabled|disabled)" with "display disabled"
system display: T2564: Lowercase model names
system display: T2564 Extend VyOS to support appliance LCDs
|
|
|
|
|
|
When running SSH from the VyOS system the source IP address can be set by:
set system options ssh-client source-address x.x.x.x
|
|
Problem was introduced in commit 740ace13 ("router-advert: T2609: add missing
verify() for prefix lifetime"). The 'infinity' literal was not converted to its
corresponding integer 0xffffffff (4294967295) for the check.
|
|
Move sshd_config file to /run so it must be generated on every boot and is
not stored accidently.
|
|
This removes additional code paths as we can instatly work with the input dict
the same was as it was done for PPPoE. This fixes the entire DHCPv6-PD support
on non PPPoE interfaces as this was lost in translation while processing T2653.
|
|
Make the port used for RADIUS accounting user configurable. This is now
valid for the following services which are based on Accel-PPP:
* ipoe-server
* pppoe-server
* l2tp
* pptp
* sstp
|
|
|
|
|
|
Migration files on the storage should be done one time by a migration script
instead of every time the configuration changes. Moving this to an older
migration script is fine as this is around for a long time and all rolling
releases are already up2date. It only affects updates from VyOS 1.2 series.
|
|
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
Further reduce the boiler-plate code to determine interface tag node or not.
It can be passed into get_interface_dict() if explicitly required - else it
is taken from the environment.
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
This can be used to see if a tagNode has been changed. It will return a list
of changed nodes.
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
|
|
After switching from raw parsing of the interface options to get_config_dict()
this utilizes another utility function which wraps get_config_dict() and adds
other common and reused parameters (like deleted or bridge member).
Overall this drops redundant code (again) and makes the rest more maintainable
as we only utilize a single function.
|
|
The current VyOS CLI parser code written in Python contains a ton of duplicates
which I can also hold myself accountable for - or maybe mainly me - depends on
the angle of judge.
While providing a new update() method in vyos.ifconfig.interfaces() this is
extended for pdeudo-ethernet interfaces in the derived class.
|