Age | Commit message (Collapse) | Author |
|
https api: T5772: check if keys are configured unless PAM auth is enabled for GraphQL
|
|
This fixes the implementation in e062a8c11 ("pppoe: T5630: allow to specify MRU
in addition to already configurable MTU") and restores the bahavior that MRU
defaults to MTU if MRU is not explicitly set.
This was the behavior in VyOS 1.3.3 and below before we added ability to define
the MRU value.
|
|
vxlan: T5753: add support for VNI filtering
|
|
unless PAM auth is enabled for GraphQL
|
|
This complements commit f5e43b136 ("http: T5762: api: make API socket backend
communication the one and only default") so we have a consistent port CLI node
across VyOS components.
|
|
Why: Smoketests fail as they can not establish IPv6 connection to uvicorn
backend server.
https://github.com/vyos/vyos-1x/pull/2481 added a bunch of new smoketests.
While debugging those failing, it was uncovered, that uvicorn only listens on
IPv4 connections
vyos@vyos# netstat -tulnp | grep 8080
(Not all processes could be identified, non-owned process info
will not be shown, you would have to be root to see it all.)
tcp 0 0 127.0.0.1:8080 0.0.0.0:* LISTEN -
As the CLI already has an option to move the API communication from an IP to a
UNIX domain socket, the best idea is to make this the default way of
communication, as we never directly talk to the API server but rather use the
NGINX reverse proxy.
|
|
In a service provider network a service provider typically supports multiple
bridge domains with overlapping vlans. One bridge domain per customer. Vlans in
each bridge domain are mapped to globally unique VXLAN VNI ranges assigned to
each customer.
Without the ability of VNI filtering, we can not provide VXLAN tunnels
with multiple tenants all requiring e.g. VLAN 10.
To Test:
set interfaces vxlan vxlan987 parameters external
set interfaces vxlan vxlan987 source-interface eth0
set interfaces vxlan vxlan987 parameters vni-filter
set interfaces vxlan vxlan987 vlan-to-vni 50 vni 10050
set interfaces vxlan vxlan987 vlan-to-vni 51 vni 10051
set interfaces vxlan vxlan987 vlan-to-vni 52 vni 10052
set interfaces vxlan vxlan987 vlan-to-vni 53 vni 10053
set interfaces vxlan vxlan987 vlan-to-vni 54 vni 10054
set interfaces vxlan vxlan987 vlan-to-vni 60 vni 10060
set interfaces vxlan vxlan987 vlan-to-vni 69 vni 10069
set interfaces bridge br0 member interface vxlan987
Add new op-mode command: show bridge vni
Interface VNI
----------- -----------
vxlan987 10050-10054
vxlan987 10060
vxlan987 10069
|
|
|
|
|
|
|
|
IGMP and PIM are two different but related things.
FRR has both combined in pimd. As we use get_config_dict() and FRR reload it
is better to have both centrally stored under the same CLI node (as FRR does,
too) to just "fire and forget" the commit to the daemon.
"set protocols igmp interface eth1" -> "set protocols pim interface eth1 igmp"
|
|
Migrate CLI configuration retrival to common get_config_dict(). In addition
add new functionality to VyOS that is PIM related and already available in FRR.
|
|
|
|
<enable|disable> commands; log and state moved to new syntax.
|
|
Add additional smoketests for web-options validation.
Also, format error messages to optionally include protocol name.
|
|
mdns: T5723: Always reload systemd daemon before applying changes
|
|
Additionally, templatize system service override and move it to the
runtime path.
|
|
T5559: Add static neighbor-proxy feature
|
|
If we add a new interface for PPPoe-server we MUST restart the
`accel-ppp@pppoe.service` as `reload` is not implemented for
accel-ppp daemon
Otherwise we have listen interface in the /run/accel-pppd/pppoe.conf
which does not work
|
|
vxlan: T3700: add bridge dependency call when altering member interfaces
|
|
Commit 7f6624f5a6f8bd ("vxlan: T3700: support VLAN tunnel mapping of VLAN aware
bridges") added support for Single VXLAN Device (SVD) containers supported by
the Linux Kernel.
When working with bridge VIFs it turned out that when deleting a VIF all the
VXLAN tunnel mappings got deleted, too. In order to avoid this, if the bridge
has a VXLAN member interface which vlan-to-vni mapping enabled, we add a
dependency that we call VXLAN conf-mode script after messing arround with the
bridge VIFs and re-create tunnel mappings.
|
|
- Migrate to ddclient 3.11.1 and enforce debian/control dependency
- Add dual stack support for additional protocols
- Restrict usage of `porkbun` protocol, VyOS configuration structure
isn't compatible with porkbun yet
- Improve and cleanup error messages
|
|
`web-options` is only applicable when using HTTP(S) web request to
obtain the IP address. Apply guard for that.
|
|
wireguard: T5707: remove previously deconfigured peer
|
|
Changing the public key of a peer (updating the key material) left the old
WireGuard peer in place, as the key removal command used the new key.
WireGuard only supports peer removal based on the configured public-key, by
deleting the entire interface this is the shortcut instead of parsing out all
peers and removing them one by one.
Peer reconfiguration will always come with a short downtime while the WireGuard
interface is recreated.
|
|
T5698 EVPN ESI Multihoming
|
|
Ability to set ip neigbhor proxy
set protocols static neighbor-proxy arp 192.0.2.1 interface 'eth0'
set protocols static neighbor-proxy arp 192.0.2.2 interface 'eth0'
set protocols static neighbor-proxy nd 2001:db8::1 interface 'eth1'
|
|
T1797: Delete VPP from vyos-1x as it is implemented in addon
|
|
vxlan: T5668: add CLI knob to enable ARP/ND suppression
|
|
As we have a bunch of options under "paramteres" already and "external" is
clearly one of them it should be migrated under that node as well.
|
|
In order to minimize the flooding of ARP and ND messages in the VXLAN network,
EVPN includes provisions [1] that allow participating VTEPs to suppress such
messages in case they know the MAC-IP binding and can reply on behalf of the
remote host. In Linux, the above is implemented in the bridge driver using a
per-port option called "neigh_suppress" that was added in kernel version 4.15.
[1] https://www.rfc-editor.org/rfc/rfc7432#section-10
|
|
set interfaces bonding bond10 evpn es-df-pref '50'
set interfaces bonding bond10 evpn es-id '10'
set interfaces bonding bond10 evpn es-sys-mac '01:23:45:67:89:ab'
set interfaces bonding bond10 member interface 'eth3'
set interfaces bonding bond10 mode '802.3ad'
|
|
T5681: Firewall,Nat and Nat66: simplified and standarize interface matcher
|
|
(valid for interfaces and groups) in firewal, nat and nat66.
|
|
The current named for certificates are hardcoded in generated config to:
- ca.pem
- cert.pem.key
- cert.pem
It cause a generated config certificates and certificates itself
are different (test-cert-1.pem and ca.pem)
bind :::8080 v4v6 ssl crt /run/haproxy/test-cert-1.pem
/run/haproxy/ca.pem
It is a bug of initial impelemtation. Fix required correct names
from PKI certificates
|
|
T5643: nat: add interface-groups to nat. Use same cli structure for i…
|
|
vxlan: T5671: change port to IANA assigned default port
|
|
|
|
T5541: firewall zone: re add firewall zone-base firewall
|
|
|
|
pmacct: T5232: Fixed pmacct service control via systemctl
|
|
|
|
pmacct daemons have one very important specific - they handle control signals in
the same loop as packets. And packets waiting is blocking operation.
Because of this, when systemctl sends SIGTERM to uacctd, this signal has no
effect until uacct receives at least one packet via nflog. In some cases, this
leads to a 90-second timeout, sending SIGKILL, and improperly finished tasks.
As a result, a working folder is not cleaned properly.
This commit contains several changes to fix service issues:
- add a new nftables table for pmacct with a single rule to get the ability to
send a packet to nflog and unlock uacctd
- remove PID file options from the uacctd and a systemd service file. Systemd
can detect proper PID, and PIDfile is created by uacctd too late, which leads
to extra errors in systemd logs
- KillMode changed to mixed. Without this, SIGTERM is sent to all plugins and
the core process exits with status 1 because it loses connection to plugins too
early. As a result, we have errors in logs, and the systemd service is in a
failed state.
- added logging to uacctd
- systemctl service modified to send packets to specific address during a service
stop which unlocks uacctd and allows systemctl to finish its work properly
|
|
bonding: T5254: Fixed changing ethernet when it is a bond member
|
|
interface-name|interface-group as in firewall.
|
|
T5165: Implement policy local-route source and destination port
|
|
|
|
T5530: isis: Adding loop free alternate feature
|
|
pppoe: T5630: allow to specify MRU in addition to already configurable MTU
|
|
Add `policy local-route` source and destination port
set policy local-route rule 23 destination port '222'
set policy local-route rule 23 protocol 'tcp'
set policy local-route rule 23 set table '123'
set policy local-route rule 23 source port '8888'
% ip rule show prio 23