Age | Commit message (Collapse) | Author |
|
This fixes the implementation in e062a8c11 ("pppoe: T5630: allow to specify MRU
in addition to already configurable MTU") and restores the bahavior that MRU
defaults to MTU if MRU is not explicitly set.
This was the behavior in VyOS 1.3.3 and below before we added ability to define
the MRU value.
|
|
vxlan: T5753: add support for VNI filtering
|
|
http: T5762: rename "virtual-host listen-port" -> "virtual-host port"
|
|
This complements commit f5e43b136 ("http: T5762: api: make API socket backend
communication the one and only default") so we have a consistent port CLI node
across VyOS components.
|
|
Add ability to reboot and poweroff the system via API
curl -k --location --request POST 'https://vyos/reboot' \
--form data='{"op": "reboot", "path": ["now"]}' \
--form key='apikey'
curl -k --location --request POST 'https://vyos/poweroff' \
--form data='{"op": "poweroff", "path": ["now"]}' \
--form key='apikey'
|
|
http: T5762: api: make API socket backend communication the one and only default
|
|
|
|
Why: Smoketests fail as they can not establish IPv6 connection to uvicorn
backend server.
https://github.com/vyos/vyos-1x/pull/2481 added a bunch of new smoketests.
While debugging those failing, it was uncovered, that uvicorn only listens on
IPv4 connections
vyos@vyos# netstat -tulnp | grep 8080
(Not all processes could be identified, non-owned process info
will not be shown, you would have to be root to see it all.)
tcp 0 0 127.0.0.1:8080 0.0.0.0:* LISTEN -
As the CLI already has an option to move the API communication from an IP to a
UNIX domain socket, the best idea is to make this the default way of
communication, as we never directly talk to the API server but rather use the
NGINX reverse proxy.
|
|
In a service provider network a service provider typically supports multiple
bridge domains with overlapping vlans. One bridge domain per customer. Vlans in
each bridge domain are mapped to globally unique VXLAN VNI ranges assigned to
each customer.
Without the ability of VNI filtering, we can not provide VXLAN tunnels
with multiple tenants all requiring e.g. VLAN 10.
To Test:
set interfaces vxlan vxlan987 parameters external
set interfaces vxlan vxlan987 source-interface eth0
set interfaces vxlan vxlan987 parameters vni-filter
set interfaces vxlan vxlan987 vlan-to-vni 50 vni 10050
set interfaces vxlan vxlan987 vlan-to-vni 51 vni 10051
set interfaces vxlan vxlan987 vlan-to-vni 52 vni 10052
set interfaces vxlan vxlan987 vlan-to-vni 53 vni 10053
set interfaces vxlan vxlan987 vlan-to-vni 54 vni 10054
set interfaces vxlan vxlan987 vlan-to-vni 60 vni 10060
set interfaces vxlan vxlan987 vlan-to-vni 69 vni 10069
set interfaces bridge br0 member interface vxlan987
Add new op-mode command: show bridge vni
Interface VNI
----------- -----------
vxlan987 10050-10054
vxlan987 10060
vxlan987 10069
|
|
T5749: Swap show interfaces and show interfaces summary
|
|
By default show VRF, MAC, MTU for `show interfaces`
The original `show interfaces` moved to `show interfacces summary`
|
|
image: T4516: Added system image tools
|
|
|
|
|
|
|
|
|
|
|
|
|
|
An attempt to upgrade to 1.2.x is caught, but error is of failed
checksum verification; add check and message.
|
|
Note that this was updated for the fix in T5739.
|
|
|
|
Add op-mode "show interfaces summary"
Add MAC, VRF and MTU options:
vyos@r4# run show interfaces summary
Codes: S - State, L - Link, u - Up, D - Down, A - Admin Down
Interface IP Address MAC VRF MTU S/L Description
----------- ----------------- ----------------- ------- ----- ----- -------------
dum0 203.0.113.1/32 96:44:ad:c5:a1:a5 default 1500 u/u
eth0 192.168.122.14/24 52:54:00:f1:fd:77 default 1500 u/u WAN
eth1 192.0.2.1/24 52:54:00:04:33:2b foo 1500 u/u LAN-eth1
eth2 - 52:54:00:40:2e:af default 1504 u/u LAN-eth2
eth3 - 52:54:00:09:a4:b4 default 1500 A/D
|
|
This commit allows management of system images with either new or legacy
tools: 'add/delete/rename system image' and 'set default' are translated
appropriately on booting between images with the old and new tools.
Consequently, the warning of the initial commit of T4516 is dropped.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This commit adds the whole set of system image tools written from the scratch in
Python that allows performing all the operations on images:
* check information
* perform installation and deletion
* versions management
Also, it contains a new service that will update the GRUB menu and keep tracking
its version in the future.
WARNING: The commit contains non-reversible changes. Because of boot menu
changes, it will not be possible to manage images from older VyOS versions after
an update.
|
|
pim(6): T5733: add missing FRR related features
|
|
|
|
|
|
|
|
|
|
|
|
IGMP and PIM are two different but related things.
FRR has both combined in pimd. As we use get_config_dict() and FRR reload it
is better to have both centrally stored under the same CLI node (as FRR does,
too) to just "fire and forget" the commit to the daemon.
"set protocols igmp interface eth1" -> "set protocols pim interface eth1 igmp"
|
|
Migrate CLI configuration retrival to common get_config_dict(). In addition
add new functionality to VyOS that is PIM related and already available in FRR.
|
|
|
|
mtr: T5658: Add VRF support for mtr (+ op_mode wrapper)
|
|
|
|
Example: we should focus on JSON output and not expose XML and CSV.
|
|
Reduce amount of duplicated (3 times) code in op-mode scripts for ping,
traceroute and mtr.
|
|
T5729: firewall: switch to valueless in
|
|
User hooks are executed using run_hookdir (defined in the /sbin/dhclient-script script) instead of run-parts. That allows user hooks to modify variables set by the dhcp client (e.g., the new_routers variable to avoid the installation of the default routes).
|
|
<enable|disable> commands; log and state moved to new syntax.
|
|
Add additional smoketests for web-options validation.
Also, format error messages to optionally include protocol name.
|
|
|