summaryrefslogtreecommitdiff
path: root/docs/operation
diff options
context:
space:
mode:
authorfett0 <fernando.gmaidana@gmail.com>2021-12-22 18:27:45 -0300
committerfett0 <fernando.gmaidana@gmail.com>2021-12-22 18:27:45 -0300
commit6ed06afb709f4a131ccb18d8e00dd18b90e19b93 (patch)
tree14071b2ab5452105113f0417129c6d73f416c985 /docs/operation
parentbbf442c94c6e3178f8391c98051d805c11c99cd9 (diff)
downloadvyos-documentation-6ed06afb709f4a131ccb18d8e00dd18b90e19b93.tar.gz
vyos-documentation-6ed06afb709f4a131ccb18d8e00dd18b90e19b93.zip
doc: raid-add-documentation
Diffstat (limited to 'docs/operation')
-rw-r--r--docs/operation/index.rst3
-rw-r--r--docs/operation/raid.rst312
2 files changed, 314 insertions, 1 deletions
diff --git a/docs/operation/index.rst b/docs/operation/index.rst
index c19afeab..e1414b3c 100644
--- a/docs/operation/index.rst
+++ b/docs/operation/index.rst
@@ -7,4 +7,5 @@ Operation Mode
:includehidden:
information
- boot-options \ No newline at end of file
+ boot-options
+ raid \ No newline at end of file
diff --git a/docs/operation/raid.rst b/docs/operation/raid.rst
new file mode 100644
index 00000000..90483e74
--- /dev/null
+++ b/docs/operation/raid.rst
@@ -0,0 +1,312 @@
+.. _raid:
+
+######
+RAID-1
+######
+
+A Redundant Array of Independent Disks (RAID) uses two or more hard disk drives
+to improve disk speed, store more data, and/or provide fault tolerance.
+There are several storage schemes possible in a RAID array, each offering a
+different combination of storage, reliability, and/or performance.
+The VyOS system supports a “RAID 1” deployment. RAID 1 allows two or more
+disks to mirror one another to provide system fault tolerance. In a RAID 1
+solution, every sector of one disk is duplicated onto every sector of all
+disks in the array. Provided even one disk in the RAID 1 set is operational,
+the system continues to run, even through disk replacement (provided that the
+hardware supports in-service replacement of drives).
+RAID 1 can be implemented using special hardware or it can be implemented in
+software. The VyOS system supports software RAID 1 on two disks.
+The VyOS implementation of RAID 1 allows the following:
+
+* Detection and reporting of disk failure
+* The ability to maintain system operation with one failed disk
+* The ability to boot the system with one failed disk
+* The ability to replace a failed disk and initiate re-mirroring
+* The ability to monitor the status of remirroring
+
+.. _raid_instalation:
+
+Installation Implications
+=========================
+
+The VyOS systems installation utility provides several options for installing
+to a RAID 1 set. You can:
+
+* Use the install system to create the RAID 1 set
+* Use the underlying Linux commands to create a RAID 1 set before running the
+ install system command.
+* Use a previously-created RAID 1 set.
+
+.. note:: Before a permanent installation, VyOS runs a live installation
+
+Configuration
+=============
+
+Non–RAID 1 System
+-----------------
+
+When the VyOS system is installed, it automatically detects the presence of two
+disks not currently part of a RAID array. In these cases, the VyOS
+installation utility automatically offers you the option of configuring RAID 1
+mirroring for the drives, with the following prompt.
+
+.. code-block:: none
+
+ Would you like to configure RAID 1 mirroring on them?
+
+* If you do not want to configure RAID 1 mirroring, enter “No” at the prompt
+ and continue with installation in the normal way.
+
+Non–RAID 1 to RAID 1
+--------------------
+
+If you reinstall a non-RAID VyOS system on a system with two identical disks
+that are not currently part of a RAID 1 set, the VyOS installation utility
+automatically offers you the option of configuring RAID 1 mirroring for the
+drives, with the following prompt.
+
+.. code-block:: none
+
+ Would you like to configure RAID 1 mirroring on them?
+
+1 - To create a new RAID 1 array, enter “Yes” at the prompt. If the system
+detects a filesystem on the partitions being used for RAID 1 it will prompt you
+to indicate whether you want to continue creating the RAID 1 array.
+
+.. code-block:: none
+
+ Continue creating array?
+
+2 - To overwrite the old filesystem, enter “Yes”.
+
+3 - The system informs you that all data on both drives will be erased. You are
+prompted to confirm that you want to continue
+
+.. code-block:: none
+
+ Are you sure you want to do this?
+
+4 - Enter “Yes” at the prompt to retain the current VyOS configuration once
+installation is complete. Enter “No” to delete the current VyOS
+configuration.
+
+5 - Continue with installation in the normal way.
+
+
+RAID 1 to Non–RAID 1
+--------------------
+
+If you reinstall VyOS software on a system with a RAID 1 set already configured,
+the installation utility will detect the array and will display the following
+prompt:
+
+.. code-block:: none
+
+ Would you like to use this one?
+
+1 - To break apart the current RAID 1 set, enter “No” at the prompt. The
+
+installation utility detects that there are two identical disks and offers you
+the option of configuring RAID 1 mirroring on them, displaying the following
+prompt:
+
+.. code-block:: none
+
+ Would you like to configure RAID 1 mirroring on them?
+
+2 - To decline to set up a new RAID 1 configuration on the disks, enter “No”
+at the prompt. The system prompts you to indicate which partition you would
+like the system installed on.
+
+.. code-block:: none
+
+ Which partition should I install the root on? [sda1]:
+
+3 - Enter the partition where you would like the system installed. The system
+then prompts you to indicate whether you want to save the old configuration
+data. This represents the current VyOS configuration.
+
+.. code-block:: none
+
+ Would you like me to save the data on it before I delete it?
+
+4 - Enter “Yes” at the prompt to retain the current VyOS configuration once
+installation is complete. Enter “No” to delete the current VyOS configuration.
+
+5 - Continue with installation in the normal way.
+
+RAID 1 to RAID 1
+----------------
+
+If you reinstall the VyOS software on a system with a RAID 1 set already
+configured, the installation utility will detect the array and will display
+the following prompt:
+
+.. code-block:: none
+
+ Would you like to use this one?
+
+1 - To continue to use the existing RAID 1 array, enter “Yes” at the prompt.
+The system prompts you to indicate whether you want to save the old
+configuration data. This represents the current VyOS configuration.
+
+.. code-block:: none
+
+ Would you like me to save the data on it before I delete it?
+
+2 - Enter “Yes” at the prompt to retain the current VyOS configuration once
+installation is complete. Enter “No” to delete all current VyOS configuration.
+
+3 - Continue with installation in the normal way.
+
+RAID 1 to new RAID 1
+--------------------
+
+You can also recreate the RAID 1 array on disk drives already configured for
+RAID-1.The installation utility will detect the array and will display the
+following prompt:
+
+.. code-block:: none
+
+ Would you like to use this one?
+
+1 - To stop using the existing RAID 1 array, enter “No” at the prompt.
+The system detects the two disks and prompts you to indicate whether you
+want to configure RAID 1 mirroring in them.
+
+.. code-block:: none
+
+ Would you like to configure RAID 1 mirroring on them?
+
+2 - To create a new RAID 1 array, enter “Yes” at the prompt. If the system
+detects a file system on the partitions being used for RAID 1 it will prompt
+you to indicate whether you want to continue creating the RAID 1 array.
+
+.. code-block:: none
+
+ Continue creating array?
+
+3 - To overwrite the old filesystem, enter “Yes”.
+
+4 - Continue with installation in the normal way.
+
+Detecting and Replacing a Failed RAID 1 Disk
+--------------------------------------------
+
+The VyOS system automatically detects a disk failure within a RAID 1 set and
+reports it to the system console. You can verify the failure by issuing the
+show raid command.
+
+To replace a bad disk within a RAID 1 set, perform the following steps:
+
+1 - Remove the failed disk from the RAID 1 set by issuing the following
+command:
+
+.. code-block:: none
+
+ vyos@vyos:~$ remove raid RAID‐1‐device member disk‐partition
+
+where RAID-1-device is the name of the RAID 1 device (for example, md0) and
+disk-partition is the name of the failed disk partition (for example, sdb2).
+
+2- Physically remove the failed disk from the system. If the drives are not
+hot-swappable, then you must shut down the system before removing the disk.
+
+3 - Replace the failed drive with a drive of the same size or larger.
+
+4 - Format the new disk for RAID 1 by issuing the following command:
+
+.. code-block:: none
+
+ vyos@vyos:~$ format <disk‐device1> like <disk‐device2>
+
+where disk-device1 is the replacement disk (for example, sdb) and disk-device2
+is the existing healthy disk (for example, sda).
+
+5-Add the replacement disk to the RAID 1 set by issuing the following command:
+
+.. code-block:: none
+
+ vyos@vyos:~$ add raid <RAID‐1‐device> member <disk‐partition>
+
+where RAID-1-device is the name of the RAID 1 device (for example, md0) and
+disk-partition is the name of the replacement disk partition
+(for example, sdb2).
+
+Operation
+=========
+
+Use this command to add a member disk partition to the RAID 1 set. Adding a
+disk partition to a RAID 1 set initiates mirror synchronization, where all data
+on the existing member partition is copied to the new partition.
+Before adding a brand new drive to a RAID 1 set, the drive must be formatted
+using
+
+.. code-block:: none
+
+ vyos@vyos:~$ add raid <RAID‐1‐device> member <disk‐partition>
+
+Use this command to format a disk to be partitioned exactly like a second disk.
+The disk to be formatted must be inactive; that is, it must not have any
+partitions mounted and it must not already be part of an active RAID 1 set.
+In formatting, no data is copied to the formatted device, but any existing data
+on the formatted device is lost.
+This command is typically used to prepare a disk to be added to a preexisting
+RAID 1 set (of which disk-device2 is already a member).
+
+.. code-block:: none
+
+ vyos@vyos:~$ format <disk‐device1> like <disk‐device2>
+
+
+Displaying information about a RAID 1 set with two members ‐ one being
+resynchronized.
+
+.. opcmd:: show raid <RAID‐1‐device>
+
+ shows output for show raid md0 as sdb1 is being added to the RAID 1
+ set and is in the process of being resynchronized.
+
+ .. code-block:: none
+
+ vyos@vyos:~$ show raid md0
+ /dev/md0:
+       Version : 00.90
+ Creation Time : Wed Oct 29 09:19:09 2008
+    Raid Level : raid1
+    Array Size : 1044800 (1020.48 MiB 1069.88 MB)
+ Used Dev Size : 1044800 (1020.48 MiB 1069.88 MB)
+  Raid Devices : 2
+ Total Devices : 2
+ Preferred Minor : 0
+   Persistence : Superblock is persistent
+   Update Time : Wed Oct 29 19:34:23 2008
+         State : active, degraded, recovering
+ Active Devices : 1
+ Working Devices : 2
+ Failed Devices : 0
+ Spare Devices : 1
+ Rebuild Status : 17% complete
+          UUID : 981abd77:9f8c8dd8:fdbf4de4:3436c70f
+        Events : 0.103
+   Number   Major   Minor   RaidDevice State
+      0       8        1        0      active sync   /dev/sda1
+      2       8       17        1      spare rebuilding   /dev/sdb1
+
+.. opcmd:: show raid <RAID‐1‐device>
+
+ Use this command to display the formatting of a hard disk.
+
+ .. code-block:: none
+
+ vyos@vyos:~$ show disk sda format
+ Disk /dev/sda: 1073 MB, 1073741824 bytes
+ 85 heads, 9 sectors/track, 2741 cylinders
+ Units = cylinders of 765 * 512 = 391680 bytes
+ Disk identifier: 0x000b7179
+  Device Boot      Start         End      Blocks   Id  System
+ /dev/sda1               6        2737     1044922+  fd  Linux raid autodetect
+
+
+
+ \ No newline at end of file