.. _coding_guidelines: Python Coding Guidelines ======================== The switch to the Python programming language for new code is not merely a change of the language, but a chance to rethink and improve the programming approach. Let's face it: VyOS is full of spaghetti code where logic for reading the VyOS config, generating daemon configs, and restarting processes is all mixed up. Python (or any other language, for that matter) does not provide automatic protection from bad design, so we need to also devise design guidelines and follow them to keep the system extensible and maintainable. But we are here to assist you and want to guide you through how you can become a good VyOS contributor. The rules we have are not there to punish you - the rules are in place to help us all. What does it mean? By having a consistent coding style it becomes very easy for new contributors and also longtime contributors to navigate through the sources and all the implied logic of the spaghetti code. Please use the following template as good starting point when developing new modules or even rewrite a whole bunch of code in the new style XML/Pyhon interface. Configuration script structure and behaviour -------------------------------------------- Your configuration script or operation mode script which is also written in Python3 should have a line break on 80 characters. This seems to be a bit odd nowadays but as some people also work remotly or programm using vi(m) this is a fair good standard which I hope we can rely on. In addition this also helps when browsing the GitHub codebase on a mobile device if you happen to be a crazy scientist. .. code-block:: python #!/usr/bin/env python3 # # Copyright (C) 2019 VyOS maintainers and contributors # # This program is free software; you can redistribute it and/or modify # it under the terms of the GNU General Public License version 2 or later as # published by the Free Software Foundation. # # This program is distributed in the hope that it will be useful, # but WITHOUT ANY WARRANTY; without even the implied warranty of # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the # GNU General Public License for more details. # # You should have received a copy of the GNU General Public License # along with this program. If not, see . import sys from vyos.config import Config from vyos.util import ConfigError def get_config(): vc = Config() # Convert the VyOS config to an abstract internal representation config = ... return config def verify(config): # Verify that configuration is valid if invalid: raise ConfigError("Descriptive message") return True def generate(config): # Generate daemon configs pass def apply(config): # Apply the generated configs to the live system pass try: config = get_config() verify(config) except ConfigError as e: print(e) sys.exit(1) The ``get_config()`` function must convert the VyOS config to an abstract, internal representation. No other function is allowed to call the ``vyos.config. Config`` object method directly. The rationale for it is that when config reads are mixed with other logic, it's very hard to change the config syntax since you need to weed out every occurrence of the old syntax. If syntax-specific code is confined to a single function, the rest of the code can be left untouched as long as the internal representation remains compatible. Another advantage is testability of the code. Mocking the entire config subsystem is hard, while constructing an internal representation by hand is way simpler. The ``verify()`` function takes your internal representation of the config and checks if it's valid, otherwise it must raise ``ConfigError`` with an error message that describes the problem and possibly suggests how to fix it. It must not make any changes to the system. The rationale for it is again testability and, in the future when the config backend is ready and every script is rewritten in this fashion, ability to execute commit dry run ("commit test" like in JunOS) and abort commit before making any changes to the system if an error is found in any component. The ``generate()`` function generates config files for system components. The ``apply()`` function applies the generated configuration to the live system. It should use non-disruptive reload whenever possible. It may execute disruptive operations such as daemon process restart if a particular component does not support non-disruptive reload, or when the expected service degradation is minimal (for example, in case of auxiliary services such as LLDPd). In case of high impact services such as VPN daemon and routing protocols, when non- disruptive reload is supported for some but not all types of configuration changes, scripts authors should make effort to determine if a configuration change can be done in a non-disruptive way and only resort to disruptive restart if it cannot be avoided. Unless absolutely necessary, configuration scripts should not modify the active configuration of system components directly. Whenever at all possible, scripts should generate a configuration file or files that can be applied with a single command such as reloading a service through systemd init. Inserting statements one by one is particularly discouraged, for example, when configuring netfilter rules, saving them to a file and loading it with iptables-restore should always be preferred to executing iptables directly. The ``apply()`` and ``generate()`` functions may ``raise ConfigError`` if, for example, the daemon failed to start with the updated config. It shouldn't be a substitute for proper config checking in the ``verify()`` function. All reasonable effort should be made to verify that generated configuration is valid and will be accepted by the daemon, including, when necessary, cross- checks with other VyOS configuration subtrees. Exceptions, including ``VyOSError`` (which is raised by ``vyos.config.Config`` on improper config operations, such as trying to use ``list_nodes()`` on a non-tag node) should not be silenced or caught and re-raised as config error. Sure this will not look pretty on user's screen, but it will make way better bug reports, and help users (and most VyOS users are IT professionals) do their own debugging as well. For easy orientation we suggest you take a look on the ``ntp.py`` or ``interfaces-bonding.py`` (for tag nodes) implementation. Both files can be found in the vyos-1x_ repository. Coding guidelines ----------------- Like any other project we have some small guidelines about our source code, too. The rules we have are not there to punish you - the rules are in place to help us all. By having a consistent coding style it becomes very easy for new and also longtime contributors to navigate through the sources and all the implied logic of any one source file.. Language ******** Python 3 **shall** be used. How long can we keep Python 2 alive anyway? No considerations for Python 2 compatibility **should** be taken at any time. Formatting ********** * Python: Tabs **shall not** be used. Every indentation level should be 4 spaces * XML: Tabs **shall not** be used. Every indentation level should be 2 spaces .. note: There are extensions to e.g. VIM (xmllint) which will help you to get your indention levels correct. Add to following to your .vimrc file: ``au FileType xml setlocal equalprg=xmllint\ --format\ --recover\ -\ 2>/dev/null`` now you can call the linter using ``gg=G`` in command mode. Text generation *************** Template processor **should** be used for generating config files. Built-in string formatting **may** be used for simple line-oriented formats where every line is self-contained, such as iptables rules. Template processor **must** be used for structured, multi-line formats such as those used by ISC DHCPd. The default template processor for VyOS code is jinja2. Code policy ----------- When modifying the source code, remember these rules of the legacy elimination campaign: * No new features in Perl * No old style command definitions * No code incompatible with Python3 .. _process: https://blog.vyos.io/vyos-development-digest-10 .. _vyos-1x: https://github.com/vyos/vyos-1x/blob/current/schema/ .. _VyConf: https://github.com/vyos/vyconf/blob/master/data/schemata