diff options
author | Christian Poessinger <christian@poessinger.com> | 2021-06-22 18:34:21 +0200 |
---|---|---|
committer | Christian Poessinger <christian@poessinger.com> | 2021-06-22 18:34:58 +0200 |
commit | 47604c76587cc6cb7742e91940de2f40ad6d7eb0 (patch) | |
tree | 719d4d06886b6c4855e3940781778a33ca4f19d3 /data/mibs/IF-INVERTED-STACK-MIB.txt | |
parent | debd7996f89b01fa8d3584efbcda9a5675ee4344 (diff) | |
download | vyos-1x-47604c76587cc6cb7742e91940de2f40ad6d7eb0.tar.gz vyos-1x-47604c76587cc6cb7742e91940de2f40ad6d7eb0.zip |
snmp: T3606: Install MIBs into well known location
FRR also expects the MIBs in /usr/share/snmp/mibs
Diffstat (limited to 'data/mibs/IF-INVERTED-STACK-MIB.txt')
-rw-r--r-- | data/mibs/IF-INVERTED-STACK-MIB.txt | 149 |
1 files changed, 0 insertions, 149 deletions
diff --git a/data/mibs/IF-INVERTED-STACK-MIB.txt b/data/mibs/IF-INVERTED-STACK-MIB.txt deleted file mode 100644 index eb8797b58..000000000 --- a/data/mibs/IF-INVERTED-STACK-MIB.txt +++ /dev/null @@ -1,149 +0,0 @@ -IF-INVERTED-STACK-MIB DEFINITIONS ::= BEGIN - -IMPORTS - MODULE-IDENTITY, OBJECT-TYPE, mib-2 FROM SNMPv2-SMI - RowStatus FROM SNMPv2-TC - MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF - ifStackGroup2, - ifStackHigherLayer, ifStackLowerLayer FROM IF-MIB; - -ifInvertedStackMIB MODULE-IDENTITY - LAST-UPDATED "200006140000Z" - ORGANIZATION "IETF Interfaces MIB Working Group" - CONTACT-INFO - " Keith McCloghrie - Cisco Systems, Inc. - 170 West Tasman Drive - San Jose, CA 95134-1706 - US - - 408-526-5260 - kzm@cisco.com" - DESCRIPTION - "The MIB module which provides the Inverted Stack Table for - interface sub-layers." - REVISION "200006140000Z" - DESCRIPTION - "Initial revision, published as RFC 2864" - ::= { mib-2 77 } - -ifInvMIBObjects OBJECT IDENTIFIER ::= { ifInvertedStackMIB 1 } - --- --- The Inverted Interface Stack Group --- - -ifInvStackTable OBJECT-TYPE - SYNTAX SEQUENCE OF IfInvStackEntry - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A table containing information on the relationships between - - the multiple sub-layers of network interfaces. In - particular, it contains information on which sub-layers run - 'underneath' which other sub-layers, where each sub-layer - corresponds to a conceptual row in the ifTable. For - example, when the sub-layer with ifIndex value x runs - underneath the sub-layer with ifIndex value y, then this - table contains: - - ifInvStackStatus.x.y=active - - For each ifIndex value, z, which identifies an active - interface, there are always at least two instantiated rows - in this table associated with z. For one of these rows, z - is the value of ifStackHigherLayer; for the other, z is the - value of ifStackLowerLayer. (If z is not involved in - multiplexing, then these are the only two rows associated - with z.) - - For example, two rows exist even for an interface which has - no others stacked on top or below it: - - ifInvStackStatus.z.0=active - ifInvStackStatus.0.z=active - - This table contains exactly the same number of rows as the - ifStackTable, but the rows appear in a different order." - REFERENCE - "ifStackTable of RFC 2863" - ::= { ifInvMIBObjects 1 } - -ifInvStackEntry OBJECT-TYPE - SYNTAX IfInvStackEntry - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Information on a particular relationship between two sub- - layers, specifying that one sub-layer runs underneath the - other sub-layer. Each sub-layer corresponds to a conceptual - row in the ifTable." - INDEX { ifStackLowerLayer, ifStackHigherLayer } - ::= { ifInvStackTable 1 } - -IfInvStackEntry ::= - SEQUENCE { - ifInvStackStatus RowStatus - } - -ifInvStackStatus OBJECT-TYPE - SYNTAX RowStatus - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The status of the relationship between two sub-layers. - - An instance of this object exists for each instance of the - ifStackStatus object, and vice versa. For example, if the - variable ifStackStatus.H.L exists, then the variable - ifInvStackStatus.L.H must also exist, and vice versa. In - addition, the two variables always have the same value. - - However, unlike ifStackStatus, the ifInvStackStatus object - is NOT write-able. A network management application wishing - to change a relationship between sub-layers H and L cannot - do so by modifying the value of ifInvStackStatus.L.H, but - must instead modify the value of ifStackStatus.H.L. After - the ifStackTable is modified, the change will be reflected - in this table." - ::= { ifInvStackEntry 1 } - --- conformance information - -ifInvConformance OBJECT IDENTIFIER ::= { ifInvMIBObjects 2 } - -ifInvGroups OBJECT IDENTIFIER ::= { ifInvConformance 1 } -ifInvCompliances OBJECT IDENTIFIER ::= { ifInvConformance 2 } - --- compliance statements - -ifInvCompliance MODULE-COMPLIANCE - STATUS current - DESCRIPTION - "The compliance statement for SNMP entities which provide - inverted information on the layering of network interfaces." - - MODULE -- this module - MANDATORY-GROUPS { ifInvStackGroup } - - OBJECT ifInvStackStatus - SYNTAX INTEGER { active(1) } - DESCRIPTION - "Support is only required for 'active'." - - MODULE IF-MIB - MANDATORY-GROUPS { ifStackGroup2 } - ::= { ifInvCompliances 1 } - --- units of conformance - -ifInvStackGroup OBJECT-GROUP - OBJECTS { ifInvStackStatus } - STATUS current - DESCRIPTION - "A collection of objects providing inverted information on - the layering of MIB-II interfaces." - ::= { ifInvGroups 1 } - -END |