summaryrefslogtreecommitdiff
path: root/mibs/DISMAN-EVENT-MIB.txt
diff options
context:
space:
mode:
authorChristian Poessinger <christian@poessinger.com>2021-06-22 18:34:21 +0200
committerChristian Poessinger <christian@poessinger.com>2021-06-22 18:34:58 +0200
commit47604c76587cc6cb7742e91940de2f40ad6d7eb0 (patch)
tree719d4d06886b6c4855e3940781778a33ca4f19d3 /mibs/DISMAN-EVENT-MIB.txt
parentdebd7996f89b01fa8d3584efbcda9a5675ee4344 (diff)
downloadvyos-1x-47604c76587cc6cb7742e91940de2f40ad6d7eb0.tar.gz
vyos-1x-47604c76587cc6cb7742e91940de2f40ad6d7eb0.zip
snmp: T3606: Install MIBs into well known location
FRR also expects the MIBs in /usr/share/snmp/mibs
Diffstat (limited to 'mibs/DISMAN-EVENT-MIB.txt')
-rw-r--r--mibs/DISMAN-EVENT-MIB.txt1882
1 files changed, 1882 insertions, 0 deletions
diff --git a/mibs/DISMAN-EVENT-MIB.txt b/mibs/DISMAN-EVENT-MIB.txt
new file mode 100644
index 000000000..f00c7cc89
--- /dev/null
+++ b/mibs/DISMAN-EVENT-MIB.txt
@@ -0,0 +1,1882 @@
+DISMAN-EVENT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ Integer32, Unsigned32,
+ NOTIFICATION-TYPE, Counter32,
+ Gauge32, mib-2, zeroDotZero FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, RowStatus,
+ TruthValue FROM SNMPv2-TC
+
+ MODULE-COMPLIANCE, OBJECT-GROUP,
+ NOTIFICATION-GROUP FROM SNMPv2-CONF
+ sysUpTime FROM SNMPv2-MIB
+ SnmpTagValue FROM SNMP-TARGET-MIB
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
+
+dismanEventMIB MODULE-IDENTITY
+ LAST-UPDATED "200010160000Z" -- 16 October 2000
+ ORGANIZATION "IETF Distributed Management Working Group"
+ CONTACT-INFO "Ramanathan Kavasseri
+ Cisco Systems, Inc.
+ 170 West Tasman Drive,
+ San Jose CA 95134-1706.
+ Phone: +1 408 526 4527
+ Email: ramk@cisco.com"
+ DESCRIPTION
+ "The MIB module for defining event triggers and actions
+ for network management purposes."
+-- Revision History
+
+ REVISION "200010160000Z" -- 16 October 2000
+ DESCRIPTION "This is the initial version of this MIB.
+ Published as RFC 2981"
+ ::= { mib-2 88 }
+
+dismanEventMIBObjects OBJECT IDENTIFIER ::= { dismanEventMIB 1 }
+
+-- Management Triggered Event (MTE) objects
+
+mteResource OBJECT IDENTIFIER ::= { dismanEventMIBObjects 1 }
+mteTrigger OBJECT IDENTIFIER ::= { dismanEventMIBObjects 2 }
+mteObjects OBJECT IDENTIFIER ::= { dismanEventMIBObjects 3 }
+mteEvent OBJECT IDENTIFIER ::= { dismanEventMIBObjects 4 }
+
+--
+-- Textual Conventions
+--
+
+FailureReason ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Reasons for failures in an attempt to perform a management
+ request.
+
+ The first group of errors, numbered less than 0, are related
+ to problems in sending the request. The existence of a
+ particular error code here does not imply that all
+ implementations are capable of sensing that error and
+
+ returning that code.
+
+ The second group, numbered greater than 0, are copied
+ directly from SNMP protocol operations and are intended to
+ carry exactly the meanings defined for the protocol as returned
+ in an SNMP response.
+
+ localResourceLack some local resource such as memory
+ lacking or
+ mteResourceSampleInstanceMaximum
+ exceeded
+ badDestination unrecognized domain name or otherwise
+ invalid destination address
+ destinationUnreachable can't get to destination address
+ noResponse no response to SNMP request
+ badType the data syntax of a retrieved object
+ as not as expected
+ sampleOverrun another sample attempt occurred before
+ the previous one completed"
+ SYNTAX INTEGER { localResourceLack(-1),
+ badDestination(-2),
+ destinationUnreachable(-3),
+ noResponse(-4),
+ badType(-5),
+ sampleOverrun(-6),
+ noError(0),
+ tooBig(1),
+ noSuchName(2),
+ badValue(3),
+ readOnly(4),
+ genErr(5),
+ noAccess(6),
+ wrongType(7),
+ wrongLength(8),
+ wrongEncoding(9),
+ wrongValue(10),
+ noCreation(11),
+ inconsistentValue(12),
+ resourceUnavailable(13),
+ commitFailed(14),
+ undoFailed(15),
+ authorizationError(16),
+ notWritable(17),
+ inconsistentName(18) }
+--
+
+-- Resource Control Section
+--
+
+mteResourceSampleMinimum OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum mteTriggerFrequency this system will
+ accept. A system may use the larger values of this minimum to
+ lessen the impact of constant sampling. For larger
+ sampling intervals the system samples less often and
+ suffers less overhead. This object provides a way to enforce
+ such lower overhead for all triggers created after it is
+ set.
+
+ Unless explicitly resource limited, a system's value for
+ this object SHOULD be 1, allowing as small as a 1 second
+ interval for ongoing trigger sampling.
+
+ Changing this value will not invalidate an existing setting
+ of mteTriggerFrequency."
+ ::= { mteResource 1 }
+
+mteResourceSampleInstanceMaximum OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "instances"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of instance entries this system will
+ support for sampling.
+
+ These are the entries that maintain state, one for each
+ instance of each sampled object as selected by
+ mteTriggerValueID. Note that wildcarded objects result
+ in multiple instances of this state.
+
+ A value of 0 indicates no preset limit, that is, the limit
+ is dynamic based on system operation and resources.
+
+ Unless explicitly resource limited, a system's value for
+ this object SHOULD be 0.
+
+ Changing this value will not eliminate or inhibit existing
+ sample state but could prevent allocation of additional state
+ information."
+ ::= { mteResource 2 }
+
+mteResourceSampleInstances OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "instances"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of currently active instance entries as
+ defined for mteResourceSampleInstanceMaximum."
+ ::= { mteResource 3 }
+
+mteResourceSampleInstancesHigh OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "instances"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The highest value of mteResourceSampleInstances that has
+ occurred since initialization of the management system."
+ ::= { mteResource 4 }
+
+mteResourceSampleInstanceLacks OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "instances"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times this system could not take a new sample
+ because that allocation would have exceeded the limit set by
+ mteResourceSampleInstanceMaximum."
+ ::= { mteResource 5 }
+
+--
+-- Trigger Section
+--
+
+-- Counters
+
+mteTriggerFailures OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "failures"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times an attempt to check for a trigger
+ condition has failed. This counts individually for each
+ attempt in a group of targets or each attempt for a
+
+ wildcarded object."
+ ::= { mteTrigger 1 }
+
+--
+-- Trigger Table
+--
+
+mteTriggerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteTriggerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event trigger information."
+ ::= { mteTrigger 2 }
+
+mteTriggerEntry OBJECT-TYPE
+ SYNTAX MteTriggerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single trigger. Applications create and
+ delete entries using mteTriggerEntryStatus."
+ INDEX { mteOwner, IMPLIED mteTriggerName }
+ ::= { mteTriggerTable 1 }
+
+MteTriggerEntry ::= SEQUENCE {
+ mteOwner SnmpAdminString,
+ mteTriggerName SnmpAdminString,
+ mteTriggerComment SnmpAdminString,
+ mteTriggerTest BITS,
+ mteTriggerSampleType INTEGER,
+ mteTriggerValueID OBJECT IDENTIFIER,
+ mteTriggerValueIDWildcard TruthValue,
+ mteTriggerTargetTag SnmpTagValue,
+ mteTriggerContextName SnmpAdminString,
+ mteTriggerContextNameWildcard TruthValue,
+ mteTriggerFrequency Unsigned32,
+ mteTriggerObjectsOwner SnmpAdminString,
+ mteTriggerObjects SnmpAdminString,
+ mteTriggerEnabled TruthValue,
+ mteTriggerEntryStatus RowStatus
+}
+
+mteOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE(0..32))
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The owner of this entry. The exact semantics of this
+ string are subject to the security policy defined by the
+ security administrator."
+ ::= { mteTriggerEntry 1 }
+
+mteTriggerName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (1..32))
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A locally-unique, administratively assigned name for the
+ trigger within the scope of mteOwner."
+ ::= { mteTriggerEntry 2 }
+
+mteTriggerComment OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A description of the trigger's function and use."
+ DEFVAL { ''H }
+ ::= { mteTriggerEntry 3 }
+
+mteTriggerTest OBJECT-TYPE
+ SYNTAX BITS { existence(0), boolean(1), threshold(2) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of trigger test to perform. For 'boolean' and
+ 'threshold' tests, the object at mteTriggerValueID MUST
+ evaluate to an integer, that is, anything that ends up encoded
+ for transmission (that is, in BER, not ASN.1) as an integer.
+
+ For 'existence', the specific test is as selected by
+ mteTriggerExistenceTest. When an object appears, vanishes
+ or changes value, the trigger fires. If the object's
+ appearance caused the trigger firing, the object MUST
+ vanish before the trigger can be fired again for it, and
+ vice versa. If the trigger fired due to a change in the
+ object's value, it will be fired again on every successive
+ value change for that object.
+
+ For 'boolean', the specific test is as selected by
+ mteTriggerBooleanTest. If the test result is true the trigger
+ fires. The trigger will not fire again until the value has
+ become false and come back to true.
+
+ For 'threshold' the test works as described below for
+
+ mteTriggerThresholdStartup, mteTriggerThresholdRising, and
+ mteTriggerThresholdFalling.
+
+ Note that combining 'boolean' and 'threshold' tests on the
+ same object may be somewhat redundant."
+ DEFVAL { { boolean } }
+ ::= { mteTriggerEntry 4 }
+
+mteTriggerSampleType OBJECT-TYPE
+ SYNTAX INTEGER { absoluteValue(1), deltaValue(2) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of sampling to perform.
+
+ An 'absoluteValue' sample requires only a single sample to be
+ meaningful, and is exactly the value of the object at
+ mteTriggerValueID at the sample time.
+
+ A 'deltaValue' requires two samples to be meaningful and is
+ thus not available for testing until the second and subsequent
+ samples after the object at mteTriggerValueID is first found
+ to exist. It is the difference between the two samples. For
+ unsigned values it is always positive, based on unsigned
+ arithmetic. For signed values it can be positive or negative.
+
+ For SNMP counters to be meaningful they should be sampled as a
+ 'deltaValue'.
+
+ For 'deltaValue' mteTriggerDeltaTable contains further
+ parameters.
+
+ If only 'existence' is set in mteTriggerTest this object has
+ no meaning."
+ DEFVAL { absoluteValue }
+ ::= { mteTriggerEntry 5 }
+
+mteTriggerValueID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the MIB object to sample to see
+ if the trigger should fire.
+
+ This may be wildcarded by truncating all or part of the
+ instance portion, in which case the value is obtained
+ as if with a GetNext function, checking multiple values
+
+ if they exist. If such wildcarding is applied,
+ mteTriggerValueIDWildcard must be 'true' and if not it must
+ be 'false'.
+
+ Bad object identifiers or a mismatch between truncating the
+ identifier and the value of mteTriggerValueIDWildcard result
+ in operation as one would expect when providing the wrong
+ identifier to a Get or GetNext operation. The Get will fail
+ or get the wrong object. The GetNext will indeed get whatever
+ is next, proceeding until it runs past the initial part of the
+ identifier and perhaps many unintended objects for confusing
+ results. If the value syntax of those objects is not usable,
+ that results in a 'badType' error that terminates the scan.
+
+ Each instance that fills the wildcard is independent of any
+ additional instances, that is, wildcarded objects operate
+ as if there were a separate table entry for each instance
+ that fills the wildcard without having to actually predict
+ all possible instances ahead of time."
+ DEFVAL { zeroDotZero }
+ ::= { mteTriggerEntry 6 }
+
+mteTriggerValueIDWildcard OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Control for whether mteTriggerValueID is to be treated as
+ fully-specified or wildcarded, with 'true' indicating wildcard."
+ DEFVAL { false }
+ ::= { mteTriggerEntry 7 }
+
+mteTriggerTargetTag OBJECT-TYPE
+ SYNTAX SnmpTagValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The tag for the target(s) from which to obtain the condition
+ for a trigger check.
+
+ A length of 0 indicates the local system. In this case,
+ access to the objects indicated by mteTriggerValueID is under
+ the security credentials of the requester that set
+ mteTriggerEntryStatus to 'active'. Those credentials are the
+ input parameters for isAccessAllowed from the Architecture for
+ Describing SNMP Management Frameworks.
+
+ Otherwise access rights are checked according to the security
+
+ parameters resulting from the tag."
+ DEFVAL { ''H }
+ ::= { mteTriggerEntry 8 }
+
+mteTriggerContextName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The management context from which to obtain mteTriggerValueID.
+
+ This may be wildcarded by leaving characters off the end. For
+ example use 'Repeater' to wildcard to 'Repeater1',
+ 'Repeater2', 'Repeater-999.87b', and so on. To indicate such
+ wildcarding is intended, mteTriggerContextNameWildcard must
+ be 'true'.
+
+ Each instance that fills the wildcard is independent of any
+ additional instances, that is, wildcarded objects operate
+ as if there were a separate table entry for each instance
+ that fills the wildcard without having to actually predict
+ all possible instances ahead of time.
+
+ Operation of this feature assumes that the local system has a
+ list of available contexts against which to apply the
+ wildcard. If the objects are being read from the local
+ system, this is clearly the system's own list of contexts.
+ For a remote system a local version of such a list is not
+ defined by any current standard and may not be available, so
+ this function MAY not be supported."
+ DEFVAL { ''H }
+ ::= { mteTriggerEntry 9 }
+
+mteTriggerContextNameWildcard OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Control for whether mteTriggerContextName is to be treated as
+ fully-specified or wildcarded, with 'true' indicating wildcard."
+ DEFVAL { false }
+ ::= { mteTriggerEntry 10 }
+
+mteTriggerFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to wait between trigger samples. To
+ encourage consistency in sampling, the interval is measured
+ from the beginning of one check to the beginning of the next
+ and the timer is restarted immediately when it expires, not
+ when the check completes.
+
+ If the next sample begins before the previous one completed the
+ system may either attempt to make the check or treat this as an
+ error condition with the error 'sampleOverrun'.
+
+ A frequency of 0 indicates instantaneous recognition of the
+ condition. This is not possible in many cases, but may
+ be supported in cases where it makes sense and the system is
+ able to do so. This feature allows the MIB to be used in
+ implementations where such interrupt-driven behavior is
+ possible and is not likely to be supported for all MIB objects
+ even then since such sampling generally has to be tightly
+ integrated into low-level code.
+
+ Systems that can support this SHOULD document those cases
+ where it can be used. In cases where it can not, setting this
+ object to 0 should be disallowed."
+ DEFVAL { 600 }
+ ::= { mteTriggerEntry 11 }
+
+mteTriggerObjectsOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerObjects, the mteOwner of a group of
+ objects from mteObjectsTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerEntry 12 }
+
+mteTriggerObjects OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The mteObjectsName of a group of objects from
+ mteObjectsTable. These objects are to be added to any
+ Notification resulting from the firing of this trigger.
+
+ A list of objects may also be added based on the event or on
+ the value of mteTriggerTest.
+
+ A length of 0 indicates no additional objects."
+ DEFVAL { ''H }
+ ::= { mteTriggerEntry 13 }
+
+mteTriggerEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A control to allow a trigger to be configured but not used.
+ When the value is 'false' the trigger is not sampled."
+ DEFVAL { false }
+ ::= { mteTriggerEntry 14 }
+
+mteTriggerEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The control that allows creation and deletion of entries.
+ Once made active an entry may not be modified except to
+ delete it."
+ ::= { mteTriggerEntry 15 }
+
+--
+-- Trigger Delta Table
+--
+
+mteTriggerDeltaTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteTriggerDeltaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event trigger information for delta
+ sampling."
+ ::= { mteTrigger 3 }
+
+mteTriggerDeltaEntry OBJECT-TYPE
+ SYNTAX MteTriggerDeltaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single trigger's delta sampling. Entries
+ automatically exist in this this table for each mteTriggerEntry
+ that has mteTriggerSampleType set to 'deltaValue'."
+ INDEX { mteOwner, IMPLIED mteTriggerName }
+ ::= { mteTriggerDeltaTable 1 }
+
+MteTriggerDeltaEntry ::= SEQUENCE {
+ mteTriggerDeltaDiscontinuityID OBJECT IDENTIFIER,
+ mteTriggerDeltaDiscontinuityIDWildcard TruthValue,
+ mteTriggerDeltaDiscontinuityIDType INTEGER
+}
+
+sysUpTimeInstance OBJECT IDENTIFIER ::= { sysUpTime 0 }
+
+mteTriggerDeltaDiscontinuityID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The OBJECT IDENTIFIER (OID) of a TimeTicks, TimeStamp, or
+ DateAndTime object that indicates a discontinuity in the value
+ at mteTriggerValueID.
+
+ The OID may be for a leaf object (e.g. sysUpTime.0) or may
+ be wildcarded to match mteTriggerValueID.
+
+ This object supports normal checking for a discontinuity in a
+ counter. Note that if this object does not point to sysUpTime
+ discontinuity checking MUST still check sysUpTime for an overall
+ discontinuity.
+
+ If the object identified is not accessible the sample attempt
+ is in error, with the error code as from an SNMP request.
+
+ Bad object identifiers or a mismatch between truncating the
+ identifier and the value of mteDeltaDiscontinuityIDWildcard
+ result in operation as one would expect when providing the
+ wrong identifier to a Get operation. The Get will fail or get
+ the wrong object. If the value syntax of those objects is not
+ usable, that results in an error that terminates the sample
+ with a 'badType' error code."
+ DEFVAL { sysUpTimeInstance }
+ ::= { mteTriggerDeltaEntry 1 }
+
+mteTriggerDeltaDiscontinuityIDWildcard OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control for whether mteTriggerDeltaDiscontinuityID is to be
+ treated as fully-specified or wildcarded, with 'true'
+ indicating wildcard. Note that the value of this object will
+ be the same as that of the corresponding instance of
+ mteTriggerValueIDWildcard when the corresponding
+
+ mteTriggerSampleType is 'deltaValue'."
+ DEFVAL { false }
+ ::= { mteTriggerDeltaEntry 2 }
+
+mteTriggerDeltaDiscontinuityIDType OBJECT-TYPE
+ SYNTAX INTEGER { timeTicks(1), timeStamp(2), dateAndTime(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value 'timeTicks' indicates the
+ mteTriggerDeltaDiscontinuityID of this row is of syntax
+ TimeTicks. The value 'timeStamp' indicates syntax TimeStamp.
+ The value 'dateAndTime' indicates syntax DateAndTime."
+ DEFVAL { timeTicks }
+ ::= { mteTriggerDeltaEntry 3 }
+
+--
+-- Trigger Existence Table
+--
+
+mteTriggerExistenceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteTriggerExistenceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event trigger information for existence
+ triggers."
+ ::= { mteTrigger 4 }
+
+mteTriggerExistenceEntry OBJECT-TYPE
+ SYNTAX MteTriggerExistenceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single existence trigger. Entries
+ automatically exist in this this table for each mteTriggerEntry
+ that has 'existence' set in mteTriggerTest."
+ INDEX { mteOwner, IMPLIED mteTriggerName }
+ ::= { mteTriggerExistenceTable 1 }
+
+MteTriggerExistenceEntry ::= SEQUENCE {
+ mteTriggerExistenceTest BITS,
+ mteTriggerExistenceStartup BITS,
+ mteTriggerExistenceObjectsOwner SnmpAdminString,
+ mteTriggerExistenceObjects SnmpAdminString,
+ mteTriggerExistenceEventOwner SnmpAdminString,
+ mteTriggerExistenceEvent SnmpAdminString
+}
+
+mteTriggerExistenceTest OBJECT-TYPE
+ SYNTAX BITS { present(0), absent(1), changed(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The type of existence test to perform. The trigger fires
+ when the object at mteTriggerValueID is seen to go from
+ present to absent, from absent to present, or to have it's
+ value changed, depending on which tests are selected:
+
+ present(0) - when this test is selected, the trigger fires
+ when the mteTriggerValueID object goes from absent to present.
+
+ absent(1) - when this test is selected, the trigger fires
+ when the mteTriggerValueID object goes from present to absent.
+ changed(2) - when this test is selected, the trigger fires
+ the mteTriggerValueID object value changes.
+
+ Once the trigger has fired for either presence or absence it
+ will not fire again for that state until the object has been
+ to the other state. "
+ DEFVAL { { present, absent } }
+ ::= { mteTriggerExistenceEntry 1 }
+
+mteTriggerExistenceStartup OBJECT-TYPE
+ SYNTAX BITS { present(0), absent(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control for whether an event may be triggered when this entry
+ is first set to 'active' and the test specified by
+ mteTriggerExistenceTest is true. Setting an option causes
+ that trigger to fire when its test is true."
+ DEFVAL { { present, absent } }
+ ::= { mteTriggerExistenceEntry 2 }
+
+mteTriggerExistenceObjectsOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerExistenceObjects, the mteOwner of a
+ group of objects from mteObjectsTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerExistenceEntry 3 }
+
+mteTriggerExistenceObjects OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteObjectsName of a group of objects from
+ mteObjectsTable. These objects are to be added to any
+ Notification resulting from the firing of this trigger for
+ this test.
+
+ A list of objects may also be added based on the overall
+ trigger, the event or other settings in mteTriggerTest.
+
+ A length of 0 indicates no additional objects."
+ DEFVAL { ''H }
+ ::= { mteTriggerExistenceEntry 4 }
+
+mteTriggerExistenceEventOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerExistenceEvent, the mteOwner of an event
+ entry from the mteEventTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerExistenceEntry 5 }
+
+mteTriggerExistenceEvent OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteEventName of the event to invoke when mteTriggerType is
+ 'existence' and this trigger fires. A length of 0 indicates no
+ event."
+ DEFVAL { ''H }
+ ::= { mteTriggerExistenceEntry 6 }
+
+--
+-- Trigger Boolean Table
+--
+
+mteTriggerBooleanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteTriggerBooleanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event trigger information for boolean
+ triggers."
+ ::= { mteTrigger 5 }
+
+mteTriggerBooleanEntry OBJECT-TYPE
+ SYNTAX MteTriggerBooleanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single boolean trigger. Entries
+ automatically exist in this this table for each mteTriggerEntry
+ that has 'boolean' set in mteTriggerTest."
+ INDEX { mteOwner, IMPLIED mteTriggerName }
+ ::= { mteTriggerBooleanTable 1 }
+
+MteTriggerBooleanEntry ::= SEQUENCE {
+ mteTriggerBooleanComparison INTEGER,
+ mteTriggerBooleanValue Integer32,
+ mteTriggerBooleanStartup TruthValue,
+ mteTriggerBooleanObjectsOwner SnmpAdminString,
+ mteTriggerBooleanObjects SnmpAdminString,
+ mteTriggerBooleanEventOwner SnmpAdminString,
+ mteTriggerBooleanEvent SnmpAdminString
+}
+
+mteTriggerBooleanComparison OBJECT-TYPE
+ SYNTAX INTEGER { unequal(1), equal(2),
+ less(3), lessOrEqual(4),
+ greater(5), greaterOrEqual(6) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The type of boolean comparison to perform.
+
+ The value at mteTriggerValueID is compared to
+ mteTriggerBooleanValue, so for example if
+ mteTriggerBooleanComparison is 'less' the result would be true
+ if the value at mteTriggerValueID is less than the value of
+ mteTriggerBooleanValue."
+ DEFVAL { unequal }
+ ::= { mteTriggerBooleanEntry 1 }
+
+mteTriggerBooleanValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value to use for the test specified by
+ mteTriggerBooleanTest."
+ DEFVAL { 0 }
+ ::= { mteTriggerBooleanEntry 2 }
+
+mteTriggerBooleanStartup OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control for whether an event may be triggered when this entry
+ is first set to 'active' or a new instance of the object at
+ mteTriggerValueID is found and the test specified by
+ mteTriggerBooleanComparison is true. In that case an event is
+ triggered if mteTriggerBooleanStartup is 'true'."
+ DEFVAL { true }
+ ::= { mteTriggerBooleanEntry 3 }
+
+mteTriggerBooleanObjectsOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerBooleanObjects, the mteOwner of a group
+ of objects from mteObjectsTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerBooleanEntry 4 }
+
+mteTriggerBooleanObjects OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteObjectsName of a group of objects from
+ mteObjectsTable. These objects are to be added to any
+ Notification resulting from the firing of this trigger for
+ this test.
+
+ A list of objects may also be added based on the overall
+ trigger, the event or other settings in mteTriggerTest.
+
+ A length of 0 indicates no additional objects."
+ DEFVAL { ''H }
+ ::= { mteTriggerBooleanEntry 5 }
+
+mteTriggerBooleanEventOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerBooleanEvent, the mteOwner of an event
+ entry from mteEventTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerBooleanEntry 6 }
+
+mteTriggerBooleanEvent OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteEventName of the event to invoke when mteTriggerType is
+ 'boolean' and this trigger fires. A length of 0 indicates no
+ event."
+ DEFVAL { ''H }
+ ::= { mteTriggerBooleanEntry 7 }
+
+--
+-- Trigger Threshold Table
+--
+
+mteTriggerThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteTriggerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event trigger information for threshold
+ triggers."
+ ::= { mteTrigger 6 }
+
+mteTriggerThresholdEntry OBJECT-TYPE
+ SYNTAX MteTriggerThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single threshold trigger. Entries
+ automatically exist in this table for each mteTriggerEntry
+ that has 'threshold' set in mteTriggerTest."
+ INDEX { mteOwner, IMPLIED mteTriggerName }
+ ::= { mteTriggerThresholdTable 1 }
+
+MteTriggerThresholdEntry ::= SEQUENCE {
+ mteTriggerThresholdStartup INTEGER,
+ mteTriggerThresholdRising Integer32,
+ mteTriggerThresholdFalling Integer32,
+ mteTriggerThresholdDeltaRising Integer32,
+ mteTriggerThresholdDeltaFalling Integer32,
+ mteTriggerThresholdObjectsOwner SnmpAdminString,
+ mteTriggerThresholdObjects SnmpAdminString,
+ mteTriggerThresholdRisingEventOwner SnmpAdminString,
+ mteTriggerThresholdRisingEvent SnmpAdminString,
+ mteTriggerThresholdFallingEventOwner SnmpAdminString,
+ mteTriggerThresholdFallingEvent SnmpAdminString,
+ mteTriggerThresholdDeltaRisingEventOwner SnmpAdminString,
+ mteTriggerThresholdDeltaRisingEvent SnmpAdminString,
+ mteTriggerThresholdDeltaFallingEventOwner SnmpAdminString,
+ mteTriggerThresholdDeltaFallingEvent SnmpAdminString
+}
+
+mteTriggerThresholdStartup OBJECT-TYPE
+ SYNTAX INTEGER { rising(1), falling(2), risingOrFalling(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The event that may be triggered when this entry is first
+ set to 'active' and a new instance of the object at
+ mteTriggerValueID is found. If the first sample after this
+ instance becomes active is greater than or equal to
+ mteTriggerThresholdRising and mteTriggerThresholdStartup is
+ equal to 'rising' or 'risingOrFalling', then one
+ mteTriggerThresholdRisingEvent is triggered for that instance.
+ If the first sample after this entry becomes active is less
+ than or equal to mteTriggerThresholdFalling and
+ mteTriggerThresholdStartup is equal to 'falling' or
+ 'risingOrFalling', then one mteTriggerThresholdRisingEvent is
+ triggered for that instance."
+ DEFVAL { risingOrFalling }
+ ::= { mteTriggerThresholdEntry 1 }
+
+mteTriggerThresholdRising OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A threshold value to check against if mteTriggerType is
+ 'threshold'.
+
+ When the current sampled value is greater than or equal to
+ this threshold, and the value at the last sampling interval
+ was less than this threshold, one
+ mteTriggerThresholdRisingEvent is triggered. That event is
+ also triggered if the first sample after this entry becomes
+ active is greater than or equal to this threshold and
+ mteTriggerThresholdStartup is equal to 'rising' or
+ 'risingOrFalling'.
+
+ After a rising event is generated, another such event is not
+ triggered until the sampled value falls below this threshold
+ and reaches mteTriggerThresholdFalling."
+ DEFVAL { 0 }
+ ::= { mteTriggerThresholdEntry 2 }
+
+mteTriggerThresholdFalling OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A threshold value to check against if mteTriggerType is
+ 'threshold'.
+
+ When the current sampled value is less than or equal to this
+ threshold, and the value at the last sampling interval was
+ greater than this threshold, one
+ mteTriggerThresholdFallingEvent is triggered. That event is
+ also triggered if the first sample after this entry becomes
+ active is less than or equal to this threshold and
+ mteTriggerThresholdStartup is equal to 'falling' or
+ 'risingOrFalling'.
+
+ After a falling event is generated, another such event is not
+ triggered until the sampled value rises above this threshold
+ and reaches mteTriggerThresholdRising."
+ DEFVAL { 0 }
+ ::= { mteTriggerThresholdEntry 3 }
+
+mteTriggerThresholdDeltaRising OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A threshold value to check against if mteTriggerType is
+ 'threshold'.
+
+ When the delta value (difference) between the current sampled
+ value (value(n)) and the previous sampled value (value(n-1))
+ is greater than or equal to this threshold,
+ and the delta value calculated at the last sampling interval
+ (i.e. value(n-1) - value(n-2)) was less than this threshold,
+ one mteTriggerThresholdDeltaRisingEvent is triggered. That event
+ is also triggered if the first delta value calculated after this
+ entry becomes active, i.e. value(2) - value(1), where value(1)
+ is the first sample taken of that instance, is greater than or
+ equal to this threshold.
+
+ After a rising event is generated, another such event is not
+ triggered until the delta value falls below this threshold and
+ reaches mteTriggerThresholdDeltaFalling."
+ DEFVAL { 0 }
+ ::= { mteTriggerThresholdEntry 4 }
+
+mteTriggerThresholdDeltaFalling OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A threshold value to check against if mteTriggerType is
+ 'threshold'.
+
+ When the delta value (difference) between the current sampled
+ value (value(n)) and the previous sampled value (value(n-1))
+ is less than or equal to this threshold,
+ and the delta value calculated at the last sampling interval
+ (i.e. value(n-1) - value(n-2)) was greater than this threshold,
+ one mteTriggerThresholdDeltaFallingEvent is triggered. That event
+ is also triggered if the first delta value calculated after this
+ entry becomes active, i.e. value(2) - value(1), where value(1)
+ is the first sample taken of that instance, is less than or
+ equal to this threshold.
+
+ After a falling event is generated, another such event is not
+ triggered until the delta value falls below this threshold and
+ reaches mteTriggerThresholdDeltaRising."
+ DEFVAL { 0 }
+ ::= { mteTriggerThresholdEntry 5 }
+
+mteTriggerThresholdObjectsOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerThresholdObjects, the mteOwner of a group
+ of objects from mteObjectsTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 6 }
+
+mteTriggerThresholdObjects OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteObjectsName of a group of objects from
+ mteObjectsTable. These objects are to be added to any
+ Notification resulting from the firing of this trigger for
+ this test.
+
+ A list of objects may also be added based on the overall
+
+ trigger, the event or other settings in mteTriggerTest.
+
+ A length of 0 indicates no additional objects."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 7 }
+
+mteTriggerThresholdRisingEventOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerThresholdRisingEvent, the mteOwner of an
+ event entry from mteEventTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 8 }
+
+mteTriggerThresholdRisingEvent OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteEventName of the event to invoke when mteTriggerType is
+ 'threshold' and this trigger fires based on
+ mteTriggerThresholdRising. A length of 0 indicates no event."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 9 }
+
+mteTriggerThresholdFallingEventOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerThresholdFallingEvent, the mteOwner of an
+ event entry from mteEventTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 10 }
+
+mteTriggerThresholdFallingEvent OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteEventName of the event to invoke when mteTriggerType is
+ 'threshold' and this trigger fires based on
+ mteTriggerThresholdFalling. A length of 0 indicates no event."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 11 }
+
+mteTriggerThresholdDeltaRisingEventOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerThresholdDeltaRisingEvent, the mteOwner
+ of an event entry from mteEventTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 12 }
+
+mteTriggerThresholdDeltaRisingEvent OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteEventName of the event to invoke when mteTriggerType is
+ 'threshold' and this trigger fires based on
+ mteTriggerThresholdDeltaRising. A length of 0 indicates
+ no event."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 13 }
+
+mteTriggerThresholdDeltaFallingEventOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteTriggerThresholdDeltaFallingEvent, the mteOwner
+ of an event entry from mteEventTable."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 14 }
+
+mteTriggerThresholdDeltaFallingEvent OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteEventName of the event to invoke when mteTriggerType is
+ 'threshold' and this trigger fires based on
+ mteTriggerThresholdDeltaFalling. A length of 0 indicates
+ no event."
+ DEFVAL { ''H }
+ ::= { mteTriggerThresholdEntry 15 }
+
+--
+-- Objects Table
+--
+
+mteObjectsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteObjectsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of objects that can be added to notifications based
+ on the trigger, trigger test, or event, as pointed to by
+ entries in those tables."
+ ::= { mteObjects 1 }
+
+mteObjectsEntry OBJECT-TYPE
+ SYNTAX MteObjectsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A group of objects. Applications create and delete entries
+ using mteObjectsEntryStatus.
+
+ When adding objects to a notification they are added in the
+ lexical order of their index in this table. Those associated
+ with a trigger come first, then trigger test, then event."
+ INDEX { mteOwner, mteObjectsName, mteObjectsIndex }
+ ::= { mteObjectsTable 1 }
+
+MteObjectsEntry ::= SEQUENCE {
+ mteObjectsName SnmpAdminString,
+ mteObjectsIndex Unsigned32,
+ mteObjectsID OBJECT IDENTIFIER,
+ mteObjectsIDWildcard TruthValue,
+ mteObjectsEntryStatus RowStatus
+ }
+
+mteObjectsName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (1..32))
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A locally-unique, administratively assigned name for a group
+ of objects."
+ ::= { mteObjectsEntry 1 }
+
+mteObjectsIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An arbitrary integer for the purpose of identifying
+ individual objects within a mteObjectsName group.
+
+ Objects within a group are placed in the notification in the
+ numerical order of this index.
+
+ Groups are placed in the notification in the order of the
+ selections for overall trigger, trigger test, and event.
+ Within trigger test they are in the same order as the
+ numerical values of the bits defined for mteTriggerTest.
+
+ Bad object identifiers or a mismatch between truncating the
+ identifier and the value of mteDeltaDiscontinuityIDWildcard
+ result in operation as one would expect when providing the
+ wrong identifier to a Get operation. The Get will fail or get
+ the wrong object. If the object is not available it is omitted
+ from the notification."
+ ::= { mteObjectsEntry 2 }
+
+mteObjectsID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The object identifier of a MIB object to add to a
+ Notification that results from the firing of a trigger.
+
+ This may be wildcarded by truncating all or part of the
+ instance portion, in which case the instance portion of the
+ OID for obtaining this object will be the same as that used
+ in obtaining the mteTriggerValueID that fired. If such
+ wildcarding is applied, mteObjectsIDWildcard must be
+ 'true' and if not it must be 'false'.
+
+ Each instance that fills the wildcard is independent of any
+ additional instances, that is, wildcarded objects operate
+ as if there were a separate table entry for each instance
+ that fills the wildcard without having to actually predict
+ all possible instances ahead of time."
+ DEFVAL { zeroDotZero }
+ ::= { mteObjectsEntry 3 }
+
+mteObjectsIDWildcard OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Control for whether mteObjectsID is to be treated as
+ fully-specified or wildcarded, with 'true' indicating wildcard."
+ DEFVAL { false }
+ ::= { mteObjectsEntry 4 }
+
+mteObjectsEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The control that allows creation and deletion of entries.
+ Once made active an entry MAY not be modified except to
+ delete it."
+ ::= { mteObjectsEntry 5 }
+
+--
+-- Event Section
+--
+
+-- Counters
+
+mteEventFailures OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times an attempt to invoke an event
+ has failed. This counts individually for each
+ attempt in a group of targets or each attempt for a
+ wildcarded trigger object."
+ ::= { mteEvent 1 }
+
+--
+-- Event Table
+--
+
+mteEventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteEventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event action information."
+ ::= { mteEvent 2 }
+
+mteEventEntry OBJECT-TYPE
+ SYNTAX MteEventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single event. Applications create and
+ delete entries using mteEventEntryStatus."
+ INDEX { mteOwner, IMPLIED mteEventName }
+ ::= { mteEventTable 1 }
+
+MteEventEntry ::= SEQUENCE {
+ mteEventName SnmpAdminString,
+ mteEventComment SnmpAdminString,
+ mteEventActions BITS,
+ mteEventEnabled TruthValue,
+ mteEventEntryStatus RowStatus
+ }
+
+mteEventName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (1..32))
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A locally-unique, administratively assigned name for the
+ event."
+ ::= { mteEventEntry 1 }
+
+mteEventComment OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A description of the event's function and use."
+ DEFVAL { ''H }
+ ::= { mteEventEntry 2 }
+
+mteEventActions OBJECT-TYPE
+ SYNTAX BITS { notification(0), set(1) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The actions to perform when this event occurs.
+
+ For 'notification', Traps and/or Informs are sent according
+ to the configuration in the SNMP Notification MIB.
+
+ For 'set', an SNMP Set operation is performed according to
+ control values in this entry."
+ DEFVAL { {} } -- No bits set.
+ ::= { mteEventEntry 3 }
+
+mteEventEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A control to allow an event to be configured but not used.
+ When the value is 'false' the event does not execute even if
+
+ triggered."
+ DEFVAL { false }
+ ::= { mteEventEntry 4 }
+
+mteEventEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The control that allows creation and deletion of entries.
+ Once made active an entry MAY not be modified except to
+ delete it."
+ ::= { mteEventEntry 5 }
+
+--
+-- Event Notification Table
+--
+
+mteEventNotificationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteEventNotificationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of information about notifications to be sent as a
+ consequence of management events."
+ ::= { mteEvent 3 }
+
+mteEventNotificationEntry OBJECT-TYPE
+ SYNTAX MteEventNotificationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single event's notification. Entries
+ automatically exist in this this table for each mteEventEntry
+ that has 'notification' set in mteEventActions."
+ INDEX { mteOwner, IMPLIED mteEventName }
+ ::= { mteEventNotificationTable 1 }
+
+MteEventNotificationEntry ::= SEQUENCE {
+ mteEventNotification OBJECT IDENTIFIER,
+ mteEventNotificationObjectsOwner SnmpAdminString,
+ mteEventNotificationObjects SnmpAdminString
+ }
+
+mteEventNotification OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object identifier from the NOTIFICATION-TYPE for the
+ notification to use if metEventActions has 'notification' set."
+ DEFVAL { zeroDotZero }
+ ::= { mteEventNotificationEntry 1 }
+
+mteEventNotificationObjectsOwner OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "To go with mteEventNotificationObjects, the mteOwner of a
+ group of objects from mteObjectsTable."
+ DEFVAL { ''H }
+ ::= { mteEventNotificationEntry 2 }
+
+mteEventNotificationObjects OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mteObjectsName of a group of objects from
+ mteObjectsTable if mteEventActions has 'notification' set.
+ These objects are to be added to any Notification generated by
+ this event.
+
+ Objects may also be added based on the trigger that stimulated
+ the event.
+
+ A length of 0 indicates no additional objects."
+ DEFVAL { ''H }
+ ::= { mteEventNotificationEntry 3 }
+
+--
+-- Event Set Table
+--
+
+mteEventSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MteEventSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of management event action information."
+ ::= { mteEvent 4 }
+
+mteEventSetEntry OBJECT-TYPE
+ SYNTAX MteEventSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a single event's set option. Entries
+ automatically exist in this this table for each mteEventEntry
+ that has 'set' set in mteEventActions."
+ INDEX { mteOwner, IMPLIED mteEventName }
+ ::= { mteEventSetTable 1 }
+
+MteEventSetEntry ::= SEQUENCE {
+ mteEventSetObject OBJECT IDENTIFIER,
+ mteEventSetObjectWildcard TruthValue,
+ mteEventSetValue Integer32,
+ mteEventSetTargetTag SnmpTagValue,
+ mteEventSetContextName SnmpAdminString,
+ mteEventSetContextNameWildcard TruthValue
+ }
+
+mteEventSetObject OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object identifier from the MIB object to set if
+ mteEventActions has 'set' set.
+
+ This object identifier may be wildcarded by leaving
+ sub-identifiers off the end, in which case
+ nteEventSetObjectWildCard must be 'true'.
+
+ If mteEventSetObject is wildcarded the instance used to set the
+ object to which it points is the same as the instance from the
+ value of mteTriggerValueID that triggered the event.
+
+ Each instance that fills the wildcard is independent of any
+ additional instances, that is, wildcarded objects operate
+ as if there were a separate table entry for each instance
+ that fills the wildcard without having to actually predict
+ all possible instances ahead of time.
+
+ Bad object identifiers or a mismatch between truncating the
+ identifier and the value of mteSetObjectWildcard
+ result in operation as one would expect when providing the
+ wrong identifier to a Set operation. The Set will fail or set
+ the wrong object. If the value syntax of the destination
+ object is not correct, the Set fails with the normal SNMP
+ error code."
+ DEFVAL { zeroDotZero }
+ ::= { mteEventSetEntry 1 }
+
+mteEventSetObjectWildcard OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control over whether mteEventSetObject is to be treated as
+ fully-specified or wildcarded, with 'true' indicating wildcard
+ if mteEventActions has 'set' set."
+ DEFVAL { false }
+ ::= { mteEventSetEntry 2 }
+
+mteEventSetValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value to which to set the object at mteEventSetObject
+ if mteEventActions has 'set' set."
+ DEFVAL { 0 }
+ ::= { mteEventSetEntry 3 }
+
+mteEventSetTargetTag OBJECT-TYPE
+ SYNTAX SnmpTagValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The tag for the target(s) at which to set the object at
+ mteEventSetObject to mteEventSetValue if mteEventActions
+ has 'set' set.
+
+ Systems limited to self management MAY reject a non-zero
+ length for the value of this object.
+
+ A length of 0 indicates the local system. In this case,
+ access to the objects indicated by mteEventSetObject is under
+ the security credentials of the requester that set
+ mteTriggerEntryStatus to 'active'. Those credentials are the
+ input parameters for isAccessAllowed from the Architecture for
+ Describing SNMP Management Frameworks.
+
+ Otherwise access rights are checked according to the security
+ parameters resulting from the tag."
+ DEFVAL { ''H }
+ ::= { mteEventSetEntry 4 }
+
+mteEventSetContextName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The management context in which to set mteEventObjectID.
+ if mteEventActions has 'set' set.
+
+ This may be wildcarded by leaving characters off the end. To
+ indicate such wildcarding mteEventSetContextNameWildcard must
+ be 'true'.
+
+ If this context name is wildcarded the value used to complete
+ the wildcarding of mteTriggerContextName will be appended."
+ DEFVAL { ''H }
+ ::= { mteEventSetEntry 5 }
+
+mteEventSetContextNameWildcard OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Control for whether mteEventSetContextName is to be treated as
+ fully-specified or wildcarded, with 'true' indicating wildcard
+ if mteEventActions has 'set' set."
+ DEFVAL { false }
+ ::= { mteEventSetEntry 6 }
+
+--
+-- Notifications
+--
+
+dismanEventMIBNotificationPrefix OBJECT IDENTIFIER ::=
+ { dismanEventMIB 2 }
+dismanEventMIBNotifications OBJECT IDENTIFIER ::=
+ { dismanEventMIBNotificationPrefix 0 }
+dismanEventMIBNotificationObjects OBJECT IDENTIFIER
+ ::= { dismanEventMIBNotificationPrefix 1 }
+
+--
+-- Notification Objects
+--
+
+mteHotTrigger OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The name of the trigger causing the notification."
+ ::= { dismanEventMIBNotificationObjects 1 }
+
+mteHotTargetName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The SNMP Target MIB's snmpTargetAddrName related to the
+ notification."
+ ::= { dismanEventMIBNotificationObjects 2 }
+
+mteHotContextName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The context name related to the notification. This MUST be as
+ fully-qualified as possible, including filling in wildcard
+ information determined in processing."
+ ::= { dismanEventMIBNotificationObjects 3 }
+
+mteHotOID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the destination object related to the
+ notification. This MUST be as fully-qualified as possible,
+ including filling in wildcard information determined in
+ processing.
+
+ For a trigger-related notification this is from
+ mteTriggerValueID.
+
+ For a set failure this is from mteEventSetObject."
+ ::= { dismanEventMIBNotificationObjects 4 }
+
+mteHotValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The value of the object at mteTriggerValueID when a
+ trigger fired."
+ ::= { dismanEventMIBNotificationObjects 5 }
+
+mteFailedReason OBJECT-TYPE
+ SYNTAX FailureReason
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The reason for the failure of an attempt to check for a
+ trigger condition or set an object in response to an event."
+ ::= { dismanEventMIBNotificationObjects 6 }
+
+--
+-- Notifications
+--
+
+mteTriggerFired NOTIFICATION-TYPE
+ OBJECTS { mteHotTrigger,
+ mteHotTargetName,
+ mteHotContextName,
+ mteHotOID,
+ mteHotValue }
+ STATUS current
+ DESCRIPTION
+ "Notification that the trigger indicated by the object
+ instances has fired, for triggers with mteTriggerType
+ 'boolean' or 'existence'."
+ ::= { dismanEventMIBNotifications 1 }
+
+mteTriggerRising NOTIFICATION-TYPE
+ OBJECTS { mteHotTrigger,
+ mteHotTargetName,
+ mteHotContextName,
+ mteHotOID,
+ mteHotValue }
+ STATUS current
+ DESCRIPTION
+ "Notification that the rising threshold was met for triggers
+ with mteTriggerType 'threshold'."
+ ::= { dismanEventMIBNotifications 2 }
+
+mteTriggerFalling NOTIFICATION-TYPE
+ OBJECTS { mteHotTrigger,
+ mteHotTargetName,
+ mteHotContextName,
+ mteHotOID,
+ mteHotValue }
+ STATUS current
+ DESCRIPTION
+ "Notification that the falling threshold was met for triggers
+ with mteTriggerType 'threshold'."
+ ::= { dismanEventMIBNotifications 3 }
+
+mteTriggerFailure NOTIFICATION-TYPE
+ OBJECTS { mteHotTrigger,
+ mteHotTargetName,
+ mteHotContextName,
+ mteHotOID,
+ mteFailedReason }
+ STATUS current
+ DESCRIPTION
+ "Notification that an attempt to check a trigger has failed.
+
+ The network manager must enable this notification only with
+ a certain fear and trembling, as it can easily crowd out more
+ important information. It should be used only to help diagnose
+ a problem that has appeared in the error counters and can not
+ be found otherwise."
+ ::= { dismanEventMIBNotifications 4 }
+
+mteEventSetFailure NOTIFICATION-TYPE
+ OBJECTS { mteHotTrigger,
+ mteHotTargetName,
+ mteHotContextName,
+ mteHotOID,
+ mteFailedReason }
+ STATUS current
+ DESCRIPTION
+ "Notification that an attempt to do a set in response to an
+ event has failed.
+
+ The network manager must enable this notification only with
+ a certain fear and trembling, as it can easily crowd out more
+ important information. It should be used only to help diagnose
+ a problem that has appeared in the error counters and can not
+ be found otherwise."
+ ::= { dismanEventMIBNotifications 5 }
+
+--
+-- Conformance
+--
+
+dismanEventMIBConformance OBJECT IDENTIFIER ::= { dismanEventMIB 3 }
+dismanEventMIBCompliances OBJECT IDENTIFIER ::=
+ { dismanEventMIBConformance 1 }
+dismanEventMIBGroups OBJECT IDENTIFIER ::=
+ { dismanEventMIBConformance 2 }
+
+-- Compliance
+
+dismanEventMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities which implement
+ the Event MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ dismanEventResourceGroup,
+ dismanEventTriggerGroup,
+ dismanEventObjectsGroup,
+ dismanEventEventGroup,
+ dismanEventNotificationObjectGroup,
+ dismanEventNotificationGroup
+ }
+
+ OBJECT mteTriggerTargetTag
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, thus limiting
+ monitoring to the local system or pre-configured
+ remote systems."
+
+ OBJECT mteEventSetTargetTag
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, thus limiting
+ setting to the local system or pre-configured
+ remote systems."
+
+ OBJECT mteTriggerValueIDWildcard
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, thus allowing
+ the system not to implement wildcarding."
+
+ OBJECT mteTriggerContextNameWildcard
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, thus allowing
+ the system not to implement wildcarding."
+
+ OBJECT mteObjectsIDWildcard
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, thus allowing
+ the system not to implement wildcarding."
+
+ OBJECT mteEventSetContextNameWildcard
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, thus allowing
+ the system not to implement wildcarding."
+ ::= { dismanEventMIBCompliances 1 }
+
+-- Units of Conformance
+
+dismanEventResourceGroup OBJECT-GROUP
+ OBJECTS {
+ mteResourceSampleMinimum,
+ mteResourceSampleInstanceMaximum,
+ mteResourceSampleInstances,
+ mteResourceSampleInstancesHigh,
+ mteResourceSampleInstanceLacks
+ }
+ STATUS current
+ DESCRIPTION
+ "Event resource status and control objects."
+ ::= { dismanEventMIBGroups 1 }
+
+dismanEventTriggerGroup OBJECT-GROUP
+ OBJECTS {
+ mteTriggerFailures,
+ mteTriggerComment,
+ mteTriggerTest,
+ mteTriggerSampleType,
+ mteTriggerValueID,
+ mteTriggerValueIDWildcard,
+ mteTriggerTargetTag,
+ mteTriggerContextName,
+ mteTriggerContextNameWildcard,
+ mteTriggerFrequency,
+ mteTriggerObjectsOwner,
+ mteTriggerObjects,
+ mteTriggerEnabled,
+ mteTriggerEntryStatus,
+ mteTriggerDeltaDiscontinuityID,
+ mteTriggerDeltaDiscontinuityIDWildcard,
+ mteTriggerDeltaDiscontinuityIDType,
+ mteTriggerExistenceTest,
+ mteTriggerExistenceStartup,
+ mteTriggerExistenceObjectsOwner,
+ mteTriggerExistenceObjects,
+ mteTriggerExistenceEventOwner,
+ mteTriggerExistenceEvent,
+ mteTriggerBooleanComparison,
+ mteTriggerBooleanValue,
+ mteTriggerBooleanStartup,
+ mteTriggerBooleanObjectsOwner,
+ mteTriggerBooleanObjects,
+ mteTriggerBooleanEventOwner,
+ mteTriggerBooleanEvent,
+ mteTriggerThresholdStartup,
+ mteTriggerThresholdObjectsOwner,
+ mteTriggerThresholdObjects,
+ mteTriggerThresholdRising,
+ mteTriggerThresholdFalling,
+ mteTriggerThresholdDeltaRising,
+ mteTriggerThresholdDeltaFalling,
+ mteTriggerThresholdRisingEventOwner,
+ mteTriggerThresholdRisingEvent,
+ mteTriggerThresholdFallingEventOwner,
+ mteTriggerThresholdFallingEvent,
+ mteTriggerThresholdDeltaRisingEventOwner,
+ mteTriggerThresholdDeltaRisingEvent,
+ mteTriggerThresholdDeltaFallingEventOwner,
+ mteTriggerThresholdDeltaFallingEvent
+ }
+ STATUS current
+ DESCRIPTION
+ "Event triggers."
+ ::= { dismanEventMIBGroups 2 }
+
+dismanEventObjectsGroup OBJECT-GROUP
+ OBJECTS {
+ mteObjectsID,
+ mteObjectsIDWildcard,
+ mteObjectsEntryStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "Supplemental objects."
+ ::= { dismanEventMIBGroups 3 }
+
+dismanEventEventGroup OBJECT-GROUP
+ OBJECTS {
+ mteEventFailures,
+ mteEventComment,
+ mteEventActions,
+ mteEventEnabled,
+ mteEventEntryStatus,
+ mteEventNotification,
+ mteEventNotificationObjectsOwner,
+ mteEventNotificationObjects,
+ mteEventSetObject,
+ mteEventSetObjectWildcard,
+ mteEventSetValue,
+ mteEventSetTargetTag,
+ mteEventSetContextName,
+ mteEventSetContextNameWildcard
+ }
+ STATUS current
+ DESCRIPTION
+ "Events."
+ ::= { dismanEventMIBGroups 4 }
+
+dismanEventNotificationObjectGroup OBJECT-GROUP
+ OBJECTS {
+ mteHotTrigger,
+ mteHotTargetName,
+ mteHotContextName,
+ mteHotOID,
+ mteHotValue,
+ mteFailedReason
+ }
+ STATUS current
+ DESCRIPTION
+ "Notification objects."
+ ::= { dismanEventMIBGroups 5 }
+
+dismanEventNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ mteTriggerFired,
+ mteTriggerRising,
+ mteTriggerFalling,
+ mteTriggerFailure,
+ mteEventSetFailure
+ }
+ STATUS current
+ DESCRIPTION
+ "Notifications."
+ ::= { dismanEventMIBGroups 6 }
+
+END