summaryrefslogtreecommitdiff
path: root/data/mibs/DISMAN-PING-MIB.txt
diff options
context:
space:
mode:
Diffstat (limited to 'data/mibs/DISMAN-PING-MIB.txt')
-rw-r--r--data/mibs/DISMAN-PING-MIB.txt1561
1 files changed, 0 insertions, 1561 deletions
diff --git a/data/mibs/DISMAN-PING-MIB.txt b/data/mibs/DISMAN-PING-MIB.txt
deleted file mode 100644
index 645ff8c7d..000000000
--- a/data/mibs/DISMAN-PING-MIB.txt
+++ /dev/null
@@ -1,1561 +0,0 @@
-DISMAN-PING-MIB DEFINITIONS ::= BEGIN
-
-IMPORTS
- MODULE-IDENTITY, OBJECT-TYPE, Integer32,
- Unsigned32, Gauge32, mib-2,
- NOTIFICATION-TYPE, OBJECT-IDENTITY
- FROM SNMPv2-SMI -- RFC2578
- TEXTUAL-CONVENTION, RowStatus,
- StorageType, DateAndTime, TruthValue
- FROM SNMPv2-TC -- RFC2579
- MODULE-COMPLIANCE, OBJECT-GROUP,
- NOTIFICATION-GROUP
- FROM SNMPv2-CONF -- RFC2580
- InterfaceIndexOrZero -- RFC2863
- FROM IF-MIB
- SnmpAdminString
- FROM SNMP-FRAMEWORK-MIB -- RFC3411
- InetAddressType, InetAddress
- FROM INET-ADDRESS-MIB; -- RFC4001
-
- pingMIB MODULE-IDENTITY
- LAST-UPDATED "200606130000Z" -- 13 June 2006
- ORGANIZATION "IETF Distributed Management Working Group"
- CONTACT-INFO
- "Juergen Quittek
-
- NEC Europe Ltd.
- Network Laboratories
- Kurfuersten-Anlage 36
- 69115 Heidelberg
- Germany
-
- Phone: +49 6221 4342-115
-
- Email: quittek@netlab.nec.de"
- DESCRIPTION
- "The Ping MIB (DISMAN-PING-MIB) provides the capability of
- controlling the use of the ping function at a remote
- host.
-
- Copyright (C) The Internet Society (2006). This version of
- this MIB module is part of RFC 4560; see the RFC itself for
- full legal notices."
-
- -- Revision history
-
- REVISION "200606130000Z" -- 13 June 2006
- DESCRIPTION
- "Updated version, published as RFC 4560.
- - Correctly considered IPv6 in DESCRIPTION
- clause of pingCtlDataSize
- - Replaced references to RFC 2575 by RFC 3415
- - Replaced references to RFC 2571 by RFC 3411
- - Replaced references to RFC 2851 by RFC 4001
- - Added DEFVAL { {} } to definition of
- pingCtlTrapGeneration
- - Changed DEFVAL of object pingCtlDescr from
- DEFVAL { '00'H } to DEFVAL { ''H }
- - Changed DEFVAL of object pingCtlSourceAddressType
- from DEFVAL { ipv4 } to DEFVAL { unknown }
- - Extended DESCRIPTION clause of pingResultsTable
- describing re-initialization of entries
- - Changed SYNTAX of pingResultsProbeResponses and
- pingResultsSentProbes from Unsigned32 to Gauge32
- - Changed status of pingCompliance to deprecated
- - Added pingFullCompliance and pingMinimumCompliance
- - Changed status of pingGroup and pingTimeStampGroup
- to deprecated
- - Added pingMinimumGroup, pingCtlRowStatusGroup,
- and pingHistoryGroup"
-
- REVISION "200009210000Z" -- 21 September 2000
- DESCRIPTION
- "Initial version, published as RFC 2925."
- ::= { mib-2 80 }
-
- -- Textual Conventions
-
- OperationResponseStatus ::= TEXTUAL-CONVENTION
- STATUS current
- DESCRIPTION
- "Used to report the result of an operation:
-
- responseReceived(1) - Operation is completed successfully.
- unknown(2) - Operation failed due to unknown error.
- internalError(3) - An implementation detected an error
- in its own processing that caused an operation
- to fail.
- requestTimedOut(4) - Operation failed to receive a
- valid reply within the time limit imposed on it.
- unknownDestinationAddress(5) - Invalid destination
- address.
- noRouteToTarget(6) - Could not find a route to target.
- interfaceInactiveToTarget(7) - The interface to be
- used in sending a probe is inactive, and an
- alternate route does not exist.
- arpFailure(8) - Unable to resolve a target address to a
- media-specific address.
- maxConcurrentLimitReached(9) - The maximum number of
- concurrent active operations would have been exceeded
- if the corresponding operation was allowed.
- unableToResolveDnsName(10) - The DNS name specified was
- unable to be mapped to an IP address.
- invalidHostAddress(11) - The IP address for a host
- has been determined to be invalid. Examples of this
- are broadcast or multicast addresses."
- SYNTAX INTEGER {
- responseReceived(1),
- unknown(2),
- internalError(3),
- requestTimedOut(4),
- unknownDestinationAddress(5),
- noRouteToTarget(6),
- interfaceInactiveToTarget(7),
- arpFailure(8),
- maxConcurrentLimitReached(9),
- unableToResolveDnsName(10),
- invalidHostAddress(11)
- }
-
- -- Top level structure of the MIB
-
- pingNotifications OBJECT IDENTIFIER ::= { pingMIB 0 }
- pingObjects OBJECT IDENTIFIER ::= { pingMIB 1 }
- pingConformance OBJECT IDENTIFIER ::= { pingMIB 2 }
-
- -- The registration node (point) for ping implementation types
-
- pingImplementationTypeDomains OBJECT IDENTIFIER ::= { pingMIB 3 }
-
- pingIcmpEcho OBJECT-IDENTITY
- STATUS current
- DESCRIPTION
- "Indicates that an implementation is using the Internet
- Control Message Protocol (ICMP) 'ECHO' facility."
- ::= { pingImplementationTypeDomains 1 }
-
- pingUdpEcho OBJECT-IDENTITY
- STATUS current
- DESCRIPTION
- "Indicates that an implementation is using the UDP echo
- port (7)."
- REFERENCE
- "RFC 862, 'Echo Protocol'."
- ::= { pingImplementationTypeDomains 2 }
-
- pingSnmpQuery OBJECT-IDENTITY
- STATUS current
- DESCRIPTION
- "Indicates that an implementation is using an SNMP query
- to calculate a round trip time."
- ::= { pingImplementationTypeDomains 3 }
-
- pingTcpConnectionAttempt OBJECT-IDENTITY
- STATUS current
- DESCRIPTION
- "Indicates that an implementation is attempting to
- connect to a TCP port in order to calculate a round
- trip time."
- ::= { pingImplementationTypeDomains 4 }
-
- -- Simple Object Definitions
-
- pingMaxConcurrentRequests OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "requests"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "The maximum number of concurrent active ping requests
- that are allowed within an agent implementation. A value
- of 0 for this object implies that there is no limit for
- the number of concurrent active requests in effect.
-
- The limit applies only to new requests being activated.
- When a new value is set, the agent will continue processing
- all the requests already active, even if their number
- exceeds the limit just imposed."
- DEFVAL { 10 }
- ::= { pingObjects 1 }
-
- -- Ping Control Table
-
- pingCtlTable OBJECT-TYPE
- SYNTAX SEQUENCE OF PingCtlEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Defines the ping Control Table for providing, via SNMP,
- the capability of performing ping operations at
- a remote host. The results of these operations are
- stored in the pingResultsTable and the
- pingProbeHistoryTable."
- ::= { pingObjects 2 }
-
- pingCtlEntry OBJECT-TYPE
- SYNTAX PingCtlEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Defines an entry in the pingCtlTable. The first index
- element, pingCtlOwnerIndex, is of type SnmpAdminString,
- a textual convention that allows for use of the SNMPv3
- View-Based Access Control Model (RFC 3415, VACM)
- and that allows a management application to identify its
- entries. The second index, pingCtlTestName (also an
- SnmpAdminString), enables the same management
- application to have multiple outstanding requests."
- INDEX {
- pingCtlOwnerIndex,
- pingCtlTestName
- }
- ::= { pingCtlTable 1 }
-
- PingCtlEntry ::=
- SEQUENCE {
- pingCtlOwnerIndex SnmpAdminString,
- pingCtlTestName SnmpAdminString,
- pingCtlTargetAddressType InetAddressType,
- pingCtlTargetAddress InetAddress,
- pingCtlDataSize Unsigned32,
- pingCtlTimeOut Unsigned32,
- pingCtlProbeCount Unsigned32,
- pingCtlAdminStatus INTEGER,
- pingCtlDataFill OCTET STRING,
- pingCtlFrequency Unsigned32,
- pingCtlMaxRows Unsigned32,
- pingCtlStorageType StorageType,
- pingCtlTrapGeneration BITS,
- pingCtlTrapProbeFailureFilter Unsigned32,
- pingCtlTrapTestFailureFilter Unsigned32,
- pingCtlType OBJECT IDENTIFIER,
- pingCtlDescr SnmpAdminString,
- pingCtlSourceAddressType InetAddressType,
- pingCtlSourceAddress InetAddress,
- pingCtlIfIndex InterfaceIndexOrZero,
- pingCtlByPassRouteTable TruthValue,
- pingCtlDSField Unsigned32,
- pingCtlRowStatus RowStatus
- }
-
- pingCtlOwnerIndex OBJECT-TYPE
- SYNTAX SnmpAdminString (SIZE(0..32))
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "To facilitate the provisioning of access control by a
- security administrator using the View-Based Access
- Control Model (RFC 2575, VACM) for tables in which
- multiple users may need to create or
- modify entries independently, the initial index is used
- as an 'owner index'. Such an initial index has a syntax
- of SnmpAdminString and can thus be trivially mapped to a
- securityName or groupName defined in VACM, in
- accordance with a security policy.
-
- When used in conjunction with such a security policy, all
- entries in the table belonging to a particular user (or
- group) will have the same value for this initial index.
- For a given user's entries in a particular table, the
- object identifiers for the information in these entries
- will have the same subidentifiers (except for the 'column'
- subidentifier) up to the end of the encoded owner index.
- To configure VACM to permit access to this portion of the
- table, one would create vacmViewTreeFamilyTable entries
- with the value of vacmViewTreeFamilySubtree including
- the owner index portion, and vacmViewTreeFamilyMask
- 'wildcarding' the column subidentifier. More elaborate
- configurations are possible."
- ::= { pingCtlEntry 1 }
-
- pingCtlTestName OBJECT-TYPE
- SYNTAX SnmpAdminString (SIZE(0..32))
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "The name of the ping test. This is locally unique, within
- the scope of a pingCtlOwnerIndex."
- ::= { pingCtlEntry 2 }
-
- pingCtlTargetAddressType OBJECT-TYPE
- SYNTAX InetAddressType
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the type of host address to be used at a remote
- host for performing a ping operation."
- DEFVAL { unknown }
- ::= { pingCtlEntry 3 }
-
- pingCtlTargetAddress OBJECT-TYPE
- SYNTAX InetAddress
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the host address to be used at a remote host for
- performing a ping operation. The host address type is
- determined by the value of the corresponding
- pingCtlTargetAddressType.
-
- A value for this object MUST be set prior to transitioning
- its corresponding pingCtlEntry to active(1) via
- pingCtlRowStatus."
- DEFVAL { ''H }
- ::= { pingCtlEntry 4 }
-
- pingCtlDataSize OBJECT-TYPE
- SYNTAX Unsigned32 (0..65507)
- UNITS "octets"
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the size of the data portion to be
- transmitted in a ping operation, in octets. Whether this
- value can be applied depends on the selected
- implementation method for performing a ping operation,
- indicated by pingCtlType in the same conceptual row.
- If the method used allows applying the value contained
-
- in this object, then it MUST be applied. If the specified
- size is not appropriate for the chosen ping method, the
- implementation SHOULD use whatever size (appropriate to
- the method) is closest to the specified size.
-
- The maximum value for this object was computed by
- subtracting the smallest possible IP header size of
- 20 octets (IPv4 header with no options) and the UDP
- header size of 8 octets from the maximum IP packet size.
- An IP packet has a maximum size of 65535 octets
- (excluding IPv6 Jumbograms)."
- DEFVAL { 0 }
- ::= { pingCtlEntry 5 }
-
- pingCtlTimeOut OBJECT-TYPE
- SYNTAX Unsigned32 (1..60)
- UNITS "seconds"
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the time-out value, in seconds, for a
- remote ping operation."
- DEFVAL { 3 }
- ::= { pingCtlEntry 6 }
-
- pingCtlProbeCount OBJECT-TYPE
- SYNTAX Unsigned32 (1..15)
- UNITS "probes"
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the number of times to perform a ping
- operation at a remote host as part of a single ping test."
- DEFVAL { 1 }
- ::= { pingCtlEntry 7 }
-
- pingCtlAdminStatus OBJECT-TYPE
- SYNTAX INTEGER {
- enabled(1), -- test should be started
- disabled(2) -- test should be stopped
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Reflects the desired state that a pingCtlEntry should be
- in:
-
- enabled(1) - Attempt to activate the test as defined by
- this pingCtlEntry.
- disabled(2) - Deactivate the test as defined by this
- pingCtlEntry.
-
- Refer to the corresponding pingResultsOperStatus to
- determine the operational state of the test defined by
- this entry."
- DEFVAL { disabled }
- ::= { pingCtlEntry 8 }
-
- pingCtlDataFill OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(0..1024))
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The content of this object is used together with the
- corresponding pingCtlDataSize value to determine how to
- fill the data portion of a probe packet. The option of
- selecting a data fill pattern can be useful when links
- are compressed or have data pattern sensitivities. The
- contents of pingCtlDataFill should be repeated in a ping
- packet when the size of the data portion of the ping
- packet is greater than the size of pingCtlDataFill."
- DEFVAL { '00'H }
- ::= { pingCtlEntry 9 }
-
- pingCtlFrequency OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "seconds"
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The number of seconds to wait before repeating a ping test
- as defined by the value of the various objects in the
- corresponding row.
-
- A single ping test consists of a series of ping probes.
- The number of probes is determined by the value of the
- corresponding pingCtlProbeCount object. After a single
- test is completed the number of seconds as defined by the
- value of pingCtlFrequency MUST elapse before the
- next ping test is started.
-
- A value of 0 for this object implies that the test
- as defined by the corresponding entry will not be
- repeated."
- DEFVAL { 0 }
- ::= { pingCtlEntry 10 }
-
- pingCtlMaxRows OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "rows"
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The maximum number of corresponding entries allowed
- in the pingProbeHistoryTable. An implementation of this
- MIB will remove the oldest corresponding entry in the
- pingProbeHistoryTable to allow the addition of an
- new entry once the number of corresponding rows in the
- pingProbeHistoryTable reaches this value.
-
- Old entries are not removed when a new test is
- started. Entries are added to the pingProbeHistoryTable
- until pingCtlMaxRows is reached before entries begin to
- be removed.
-
- A value of 0 for this object disables creation of
- pingProbeHistoryTable entries."
- DEFVAL { 50 }
- ::= { pingCtlEntry 11 }
-
- pingCtlStorageType OBJECT-TYPE
- SYNTAX StorageType
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The storage type for this conceptual row.
- Conceptual rows having the value 'permanent' need not
- allow write-access to any columnar objects in the row."
- DEFVAL { nonVolatile }
- ::= { pingCtlEntry 12 }
-
- pingCtlTrapGeneration OBJECT-TYPE
- SYNTAX BITS {
- probeFailure(0),
- testFailure(1),
- testCompletion(2)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object determines when and whether
- to generate a notification for this entry:
-
- probeFailure(0) - Generate a pingProbeFailed
- notification subject to the value of
- pingCtlTrapProbeFailureFilter. The object
- pingCtlTrapProbeFailureFilter can be used
- to specify the number of consecutive probe
- failures that are required before a
- pingProbeFailed notification can be generated.
- testFailure(1) - Generate a pingTestFailed
- notification. In this instance the object
- pingCtlTrapTestFailureFilter can be used to
- determine the number of probe failures that
- signal when a test fails.
- testCompletion(2) - Generate a pingTestCompleted
- notification.
-
- By default, no bits are set, indicating that
- none of the above options is selected."
- DEFVAL { {} } -- no bits set.
- ::= { pingCtlEntry 13 }
-
- pingCtlTrapProbeFailureFilter OBJECT-TYPE
- SYNTAX Unsigned32 (0..15)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is used to determine when
- to generate a pingProbeFailed NOTIFICATION.
-
- Setting BIT probeFailure(0) of object
- pingCtlTrapGeneration to '1' implies that a
- pingProbeFailed NOTIFICATION is generated only when
-
- a number of consecutive ping probes equal to the
- value of pingCtlTrapProbeFailureFilter fail within
- a given ping test. After triggering the notification,
- the probe failure counter is reset to zero."
- DEFVAL { 1 }
- ::= { pingCtlEntry 14 }
-
- pingCtlTrapTestFailureFilter OBJECT-TYPE
- SYNTAX Unsigned32 (0..15)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is used to determine when
- to generate a pingTestFailed NOTIFICATION.
-
- Setting BIT testFailure(1) of object
-
- pingCtlTrapGeneration to '1' implies that a
- pingTestFailed NOTIFICATION is generated only when
- a number of consecutive ping tests equal to the
- value of pingCtlTrapProbeFailureFilter fail.
- After triggering the notification, the test failure
- counter is reset to zero."
- DEFVAL { 1 }
- ::= { pingCtlEntry 15 }
-
- pingCtlType OBJECT-TYPE
- SYNTAX OBJECT IDENTIFIER
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The value of this object is used either to report or
- to select the implementation method to be used for
- calculating a ping response time. The value of this
- object MAY be selected from pingImplementationTypeDomains.
-
- Additional implementation types SHOULD be allocated as
- required by implementers of the DISMAN-PING-MIB under
- their enterprise-specific registration point and not
- beneath pingImplementationTypeDomains."
- DEFVAL { pingIcmpEcho }
- ::= { pingCtlEntry 16 }
-
- pingCtlDescr OBJECT-TYPE
- SYNTAX SnmpAdminString
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The purpose of this object is to provide a
- descriptive name of the remote ping test."
- DEFVAL { ''H }
- ::= { pingCtlEntry 17 }
-
- pingCtlSourceAddressType OBJECT-TYPE
- SYNTAX InetAddressType
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the type of the source address,
- pingCtlSourceAddress, to be used at a remote host
- when a ping operation is performed."
- DEFVAL { unknown }
- ::= { pingCtlEntry 18 }
-
- pingCtlSourceAddress OBJECT-TYPE
- SYNTAX InetAddress
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Use the specified IP address (which must be given in
- numeric form, not as a hostname) as the source address
- in outgoing probe packets. On hosts with more than one
- IP address, this option can be used to select the address
- to be used. If the IP address is not one of this
- machine's interface addresses, an error is returned and
- nothing is sent. A zero-length octet string value for
- this object disables source address specification.
-
- The address type (InetAddressType) that relates to
- this object is specified by the corresponding value
- of pingCtlSourceAddressType."
- DEFVAL { ''H }
- ::= { pingCtlEntry 19 }
-
- pingCtlIfIndex OBJECT-TYPE
- SYNTAX InterfaceIndexOrZero
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Setting this object to an interface's ifIndex prior
- to starting a remote ping operation directs
- the ping probes to be transmitted over the
- specified interface. A value of zero for this object
- means that this option is not enabled."
- DEFVAL { 0 }
- ::= { pingCtlEntry 20 }
-
- pingCtlByPassRouteTable OBJECT-TYPE
- SYNTAX TruthValue
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "The purpose of this object is to enable optional
- bypassing the route table. If enabled, the remote
- host will bypass the normal routing tables and send
- directly to a host on an attached network. If the
- host is not on a directly attached network, an
- error is returned. This option can be used to perform
- the ping operation to a local host through an
- interface that has no route defined (e.g., after the
- interface was dropped by the routing daemon at the host)."
- DEFVAL { false }
- ::= { pingCtlEntry 21 }
-
- pingCtlDSField OBJECT-TYPE
- SYNTAX Unsigned32 (0..255)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "Specifies the value to store in the Type of Service
- (TOS) octet in the IPv4 header or in the Traffic
- Class octet in the IPv6 header, respectively, of the
- IP packet used to encapsulate the ping probe.
-
- The octet to be set in the IP header contains the
- Differentiated Services (DS) Field in the six most
- significant bits.
-
- This option can be used to determine what effect an
- explicit DS Field setting has on a ping response.
- Not all values are legal or meaningful. A value of 0
- means that the function represented by this option is
- not supported. DS Field usage is often not supported
- by IP implementations, and not all values are supported.
- Refer to RFC 2474 and RFC 3260 for guidance on usage of
- this field."
- REFERENCE
- "Refer to RFC 1812 for the definition of the IPv4 TOS
- octet and to RFC 2460 for the definition of the IPv6
- Traffic Class octet. Refer to RFC 2474 and RFC 3260
- for the definition of the Differentiated Services Field."
- DEFVAL { 0 }
- ::= { pingCtlEntry 22 }
-
- pingCtlRowStatus OBJECT-TYPE
- SYNTAX RowStatus
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object allows entries to be created and deleted
- in the pingCtlTable. Deletion of an entry in this
- table results in the deletion of all corresponding (same
- pingCtlOwnerIndex and pingCtlTestName index values)
- pingResultsTable and pingProbeHistoryTable entries.
-
- A value MUST be specified for pingCtlTargetAddress
- prior to acceptance of a transition to active(1) state.
-
- When a value for pingCtlTargetAddress is set,
- the value of object pingCtlRowStatus changes
- from notReady(3) to notInService(2).
-
- Activation of a remote ping operation is controlled
- via pingCtlAdminStatus, not by changing
- this object's value to active(1).
-
- Transitions in and out of active(1) state are not
- allowed while an entry's pingResultsOperStatus is
- active(1), with the exception that deletion of
- an entry in this table by setting its RowStatus
- object to destroy(6) will stop an active
- ping operation.
-
- The operational state of a ping operation
- can be determined by examination of its
- pingResultsOperStatus object."
- REFERENCE
- "See definition of RowStatus in RFC 2579, 'Textual
- Conventions for SMIv2.'"
- ::= { pingCtlEntry 23 }
-
--- Ping Results Table
-
- pingResultsTable OBJECT-TYPE
- SYNTAX SEQUENCE OF PingResultsEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Defines the Ping Results Table for providing
- the capability of performing ping operations at
- a remote host. The results of these operations are
- stored in the pingResultsTable and the pingProbeHistoryTable.
-
- An entry is added to the pingResultsTable when an
- pingCtlEntry is started by successful transition
- of its pingCtlAdminStatus object to enabled(1).
-
- If the object pingCtlAdminStatus already has the value
- enabled(1), and if the corresponding pingResultsOperStatus
- object has the value completed(3), then successfully writing
- enabled(1) to object pingCtlAdminStatus re-initializes the
- already existing entry in the pingResultsTable. The values
- of objects in the re-initialized entry are the same as the
- values of objects in a new entry would be.
-
- An entry is removed from the pingResultsTable when
- its corresponding pingCtlEntry is deleted."
- ::= { pingObjects 3 }
-
- pingResultsEntry OBJECT-TYPE
- SYNTAX PingResultsEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Defines an entry in the pingResultsTable. The
- pingResultsTable has the same indexing as the
- pingCtlTable so that a pingResultsEntry
- corresponds to the pingCtlEntry that caused it to
- be created."
- INDEX {
- pingCtlOwnerIndex,
- pingCtlTestName
- }
- ::= { pingResultsTable 1 }
-
- PingResultsEntry ::=
- SEQUENCE {
- pingResultsOperStatus INTEGER,
- pingResultsIpTargetAddressType InetAddressType,
- pingResultsIpTargetAddress InetAddress,
- pingResultsMinRtt Unsigned32,
- pingResultsMaxRtt Unsigned32,
- pingResultsAverageRtt Unsigned32,
- pingResultsProbeResponses Gauge32,
- pingResultsSentProbes Gauge32,
- pingResultsRttSumOfSquares Unsigned32,
- pingResultsLastGoodProbe DateAndTime
- }
-
- pingResultsOperStatus OBJECT-TYPE
- SYNTAX INTEGER {
- enabled(1), -- test is in progress
- disabled(2), -- test has stopped
- completed(3) -- test is completed
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Reflects the operational state of a pingCtlEntry:
-
- enabled(1) - Test is active.
- disabled(2) - Test has stopped.
- completed(3) - Test is completed."
- ::= { pingResultsEntry 1 }
-
- pingResultsIpTargetAddressType OBJECT-TYPE
- SYNTAX InetAddressType
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object indicates the type of address stored
- in the corresponding pingResultsIpTargetAddress
- object."
- DEFVAL { unknown }
- ::= { pingResultsEntry 2 }
-
- pingResultsIpTargetAddress OBJECT-TYPE
- SYNTAX InetAddress
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reports the IP address associated
- with a pingCtlTargetAddress value when the destination
- address is specified as a DNS name. The value of
- this object should be a zero-length octet string
- when a DNS name is not specified or when a
- specified DNS name fails to resolve.
-
- The address type (InetAddressType) that relates to
- this object is specified by the corresponding value
- of pingResultsIpTargetAddressType."
- DEFVAL { ''H }
- ::= { pingResultsEntry 3 }
-
- pingResultsMinRtt OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "milliseconds"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The minimum ping round-trip-time (RTT) received. A value
- of 0 for this object implies that no RTT has been received."
- ::= { pingResultsEntry 4 }
-
- pingResultsMaxRtt OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "milliseconds"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The maximum ping round-trip-time (RTT) received. A value
- of 0 for this object implies that no RTT has been received."
- ::= { pingResultsEntry 5 }
-
- pingResultsAverageRtt OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "milliseconds"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The current average ping round-trip-time (RTT)."
- ::= { pingResultsEntry 6 }
-
- pingResultsProbeResponses OBJECT-TYPE
- SYNTAX Gauge32
- UNITS "responses"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Number of responses received for the corresponding
- pingCtlEntry and pingResultsEntry. The value of this object
- MUST be reported as 0 when no probe responses have been
- received."
- ::= { pingResultsEntry 7 }
-
- pingResultsSentProbes OBJECT-TYPE
- SYNTAX Gauge32
- UNITS "probes"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The value of this object reflects the number of probes sent
- for the corresponding pingCtlEntry and pingResultsEntry.
- The value of this object MUST be reported as 0 when no probes
- have been sent."
- ::= { pingResultsEntry 8 }
-
- pingResultsRttSumOfSquares OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "milliseconds"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object contains the sum of the squares for all ping
- responses received. Its purpose is to enable standard
- deviation calculation. The value of this object MUST
- be reported as 0 when no ping responses have been
- received."
- ::= { pingResultsEntry 9 }
-
- pingResultsLastGoodProbe OBJECT-TYPE
- SYNTAX DateAndTime
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Date and time when the last response was received for
- a probe."
- ::= { pingResultsEntry 10 }
-
- -- Ping Probe History Table
-
- pingProbeHistoryTable OBJECT-TYPE
- SYNTAX SEQUENCE OF PingProbeHistoryEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Defines a table for storing the results of ping
- operations. The number of entries in this table is
- limited per entry in the pingCtlTable by the value
- of the corresponding pingCtlMaxRows object.
-
- An entry in this table is created when the result of
- a ping probe is determined. The initial 2 instance
- identifier index values identify the pingCtlEntry
- that a probe result (pingProbeHistoryEntry) belongs
- to. An entry is removed from this table when
- its corresponding pingCtlEntry is deleted.
-
- An implementation of this MIB will remove the oldest
- entry in the pingProbeHistoryTable of the
- corresponding entry in the pingCtlTable to allow
- the addition of an new entry once the number of rows
- in the pingProbeHistoryTable reaches the value
- specified by pingCtlMaxRows for the corresponding
- entry in the pingCtlTable."
- ::= { pingObjects 4 }
-
- pingProbeHistoryEntry OBJECT-TYPE
- SYNTAX PingProbeHistoryEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Defines an entry in the pingProbeHistoryTable.
- The first two index elements identify the
- pingCtlEntry that a pingProbeHistoryEntry belongs
- to. The third index element selects a single
- probe result."
- INDEX {
-
- pingCtlOwnerIndex,
- pingCtlTestName,
- pingProbeHistoryIndex
- }
- ::= { pingProbeHistoryTable 1 }
-
- PingProbeHistoryEntry ::=
- SEQUENCE {
- pingProbeHistoryIndex Unsigned32,
- pingProbeHistoryResponse Unsigned32,
- pingProbeHistoryStatus OperationResponseStatus,
- pingProbeHistoryLastRC Integer32,
- pingProbeHistoryTime DateAndTime
- }
-
- pingProbeHistoryIndex OBJECT-TYPE
- SYNTAX Unsigned32 (1..'ffffffff'h)
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry in this table is created when the result of
- a ping probe is determined. The initial 2 instance
- identifier index values identify the pingCtlEntry
- that a probe result (pingProbeHistoryEntry) belongs
- to.
-
- An implementation MUST start assigning
- pingProbeHistoryIndex values at 1 and wrap after
- exceeding the maximum possible value as defined by
- the limit of this object ('ffffffff'h)."
- ::= { pingProbeHistoryEntry 1 }
-
- pingProbeHistoryResponse OBJECT-TYPE
- SYNTAX Unsigned32
- UNITS "milliseconds"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The amount of time measured in milliseconds from when
- a probe was sent to when its response was received or
- when it timed out. The value of this object is reported
- as 0 when it is not possible to transmit a probe."
- ::= { pingProbeHistoryEntry 2 }
-
- pingProbeHistoryStatus OBJECT-TYPE
- SYNTAX OperationResponseStatus
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The result of a particular probe done by a remote host."
- ::= { pingProbeHistoryEntry 3 }
-
- pingProbeHistoryLastRC OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The last implementation-method-specific reply code received.
- If the ICMP Echo capability is being used, then a successful
- probe ends when an ICMP response is received that contains
- the code ICMP_ECHOREPLY(0). The ICMP codes are maintained
- by IANA. Standardized ICMP codes are listed at
- http://www.iana.org/assignments/icmp-parameters.
- The ICMPv6 codes are listed at
- http://www.iana.org/assignments/icmpv6-parameters."
- ::= { pingProbeHistoryEntry 4 }
-
- pingProbeHistoryTime OBJECT-TYPE
- SYNTAX DateAndTime
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Timestamp for when this probe result was determined."
- ::= { pingProbeHistoryEntry 5 }
-
- -- Notification Definition section
-
- pingProbeFailed NOTIFICATION-TYPE
- OBJECTS {
- pingCtlTargetAddressType,
- pingCtlTargetAddress,
- pingResultsOperStatus,
- pingResultsIpTargetAddressType,
- pingResultsIpTargetAddress,
- pingResultsMinRtt,
- pingResultsMaxRtt,
- pingResultsAverageRtt,
- pingResultsProbeResponses,
- pingResultsSentProbes,
- pingResultsRttSumOfSquares,
- pingResultsLastGoodProbe
- }
- STATUS current
- DESCRIPTION
- "Generated when a probe failure is detected, when the
-
- corresponding pingCtlTrapGeneration object is set to
- probeFailure(0), subject to the value of
- pingCtlTrapProbeFailureFilter. The object
- pingCtlTrapProbeFailureFilter can be used to specify the
- number of consecutive probe failures that are required
- before this notification can be generated."
- ::= { pingNotifications 1 }
-
- pingTestFailed NOTIFICATION-TYPE
- OBJECTS {
- pingCtlTargetAddressType,
- pingCtlTargetAddress,
- pingResultsOperStatus,
- pingResultsIpTargetAddressType,
- pingResultsIpTargetAddress,
- pingResultsMinRtt,
- pingResultsMaxRtt,
- pingResultsAverageRtt,
- pingResultsProbeResponses,
- pingResultsSentProbes,
- pingResultsRttSumOfSquares,
- pingResultsLastGoodProbe
- }
- STATUS current
- DESCRIPTION
- "Generated when a ping test is determined to have failed,
- when the corresponding pingCtlTrapGeneration object is
- set to testFailure(1). In this instance,
- pingCtlTrapTestFailureFilter should specify the number of
- probes in a test required to have failed in order to
- consider the test failed."
- ::= { pingNotifications 2 }
-
- pingTestCompleted NOTIFICATION-TYPE
- OBJECTS {
- pingCtlTargetAddressType,
- pingCtlTargetAddress,
- pingResultsOperStatus,
- pingResultsIpTargetAddressType,
- pingResultsIpTargetAddress,
- pingResultsMinRtt,
- pingResultsMaxRtt,
- pingResultsAverageRtt,
- pingResultsProbeResponses,
- pingResultsSentProbes,
- pingResultsRttSumOfSquares,
- pingResultsLastGoodProbe
-
- }
- STATUS current
- DESCRIPTION
- "Generated at the completion of a ping test when the
- corresponding pingCtlTrapGeneration object has the
- testCompletion(2) bit set."
- ::= { pingNotifications 3 }
-
- -- Conformance information
-
- -- Compliance statements
-
- pingCompliances OBJECT IDENTIFIER ::= { pingConformance 1 }
- pingGroups OBJECT IDENTIFIER ::= { pingConformance 2 }
-
- -- Compliance statements
-
- pingFullCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "The compliance statement for SNMP entities that
- fully implement the DISMAN-PING-MIB."
- MODULE -- this module
- MANDATORY-GROUPS {
- pingMinimumGroup,
- pingCtlRowStatusGroup,
- pingHistoryGroup,
- pingNotificationsGroup
- }
-
- OBJECT pingMaxConcurrentRequests
- MIN-ACCESS read-only
- DESCRIPTION
- "The agent is not required to support set
- operations to this object."
-
- OBJECT pingCtlStorageType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT pingCtlType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. In addition, the only
- value that MUST be supported by an implementation is
- pingIcmpEcho."
-
- OBJECT pingCtlSourceAddressType
- SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access to this object is not required by
- implementations that are not capable of binding the
- send socket with a source address. An implementation
- is only required to support IPv4 and IPv6 addresses."
-
- OBJECT pingCtlSourceAddress
- SYNTAX InetAddress (SIZE(0|4|16))
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access to this object is not required by
- implementations that are not capable of binding the
- send socket with a source address. An implementation
- is only required to support IPv4 and IPv6 addresses."
-
- OBJECT pingCtlIfIndex
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If write access is
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingCtlByPassRouteTable
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access to this object is not required by
- implementations that are not capable of its
- implementation. The function represented by this
- object is implementable if the setsockopt
- SOL_SOCKET SO_DONTROUTE option is supported."
-
- OBJECT pingCtlDSField
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If write access is
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingResultsIpTargetAddressType
- SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
- DESCRIPTION
- "An implementation is only required to
-
- support IPv4 and IPv6 addresses."
-
- OBJECT pingResultsIpTargetAddress
- SYNTAX InetAddress (SIZE(0|4|16))
- DESCRIPTION
- "An implementation is only required to
- support IPv4 and globally unique IPv6 addresses."
-
- OBJECT pingResultsLastGoodProbe
- DESCRIPTION
- "This object is mandatory for implementations that have
- access to a system clock and that are capable of setting
- the values for DateAndTime objects. It is RECOMMENDED
- that when this object is not supported its values
- be reported as '0000000000000000'H."
-
- OBJECT pingProbeHistoryTime
- DESCRIPTION
- "This object is mandatory for implementations that have
- access to a system clock and that are capable of setting
- the values for DateAndTime objects. It is RECOMMENDED
- that when this object is not supported its values
- be reported as '0000000000000000'H."
- ::= { pingCompliances 2 }
-
- pingMinimumCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "The minimum compliance statement for SNMP entities
- that implement the minimal subset of the
- DISMAN-PING-MIB. Implementors might choose this
- subset for small devices with limited resources."
- MODULE -- this module
- MANDATORY-GROUPS { pingMinimumGroup }
-
- GROUP pingCtlRowStatusGroup
- DESCRIPTION
- "A compliant implementation does not have to implement
- the pingCtlRowStatusGroup."
-
- GROUP pingHistoryGroup
- DESCRIPTION
- "A compliant implementation does not have to implement
- the pingHistoryGroup."
-
- GROUP pingNotificationsGroup
- DESCRIPTION
- "A compliant implementation does not have to implement
-
- the pingNotificationsGroup."
-
- OBJECT pingMaxConcurrentRequests
- MIN-ACCESS read-only
- DESCRIPTION
- "The agent is not required to support set
- operations to this object."
-
- OBJECT pingCtlDataFill
- MIN-ACCESS read-only
- DESCRIPTION
- "The agent is not required to support set
- operations to this object."
-
- OBJECT pingCtlFrequency
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If write access is
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingCtlMaxRows
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If the
- pingHistoryGroup is not implemented, then write
- access to this object MUST be disabled, and the object
- MUST return a value of 0 when retrieved."
-
- OBJECT pingCtlStorageType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT pingCtlTrapGeneration
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If the
- pingNotificationsGroup is not implemented, then write
- access to this object MUST be disabled, and the object
- MUST return a value with no bit set when retrieved.
- No bit set indicates that not notification is
- generated."
-
- OBJECT pingCtlTrapProbeFailureFilter
- MIN-ACCESS read-only
- DESCRIPTION
- "If write access to pingCtlTrapGeneration is not
- supported, then write access to this object must also
- not be supported. In this case, return 0 as the value
- of this object."
-
- OBJECT pingCtlTrapTestFailureFilter
- MIN-ACCESS read-only
- DESCRIPTION
- "If write access to pingCtlTrapGeneration is not
- supported, then write access to this object must also
- not be supported. In this case, return 0 as the value
- of this object."
-
- OBJECT pingCtlType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. In addition, the only
- value that MUST be supported by an implementation is
- pingIcmpEcho."
-
- OBJECT pingCtlDescr
- MIN-ACCESS read-only
- DESCRIPTION
- "The agent is not required to support set
- operations to this object."
-
- OBJECT pingCtlSourceAddressType
- SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access to this object is not required by
- implementations that are not capable of binding the
- send socket with a source address. An implementation
- is only required to support IPv4 and IPv6 addresses."
-
- OBJECT pingCtlSourceAddress
- SYNTAX InetAddress (SIZE(0|4|16))
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access to this object is not required by
- implementations that are not capable of binding the
- send socket with a source address. An implementation
- is only required to support IPv4 and IPv6 addresses."
-
- OBJECT pingCtlIfIndex
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If write access is
-
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingCtlByPassRouteTable
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If write access is
- not supported, return false(2) as the value of this
- object. A value of false(2) means that the function
- represented by this option is not supported."
-
- OBJECT pingCtlDSField
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. If write access is
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingResultsIpTargetAddressType
- SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
- DESCRIPTION
- "An implementation is only required to
- support IPv4 and IPv6 addresses."
-
- OBJECT pingResultsIpTargetAddress
- SYNTAX InetAddress (SIZE(0|4|16))
- DESCRIPTION
- "An implementation is only required to
- support IPv4 and globally unique IPv6 addresses."
-
- OBJECT pingResultsLastGoodProbe
- DESCRIPTION
- "This object is mandatory for implementations that have
- access to a system clock and that are capable of setting
- the values for DateAndTime objects. It is RECOMMENDED
- that when this object is not supported its values
- be reported as '0000000000000000'H."
-
- OBJECT pingProbeHistoryTime
- DESCRIPTION
- "If the pingHistoryGroup is implemented, then this
- object is mandatory for implementations that have
- access to a system clock and that are capable of setting
- the values for DateAndTime objects. It is RECOMMENDED
- that when this object is not supported its values
-
- be reported as '0000000000000000'H."
- ::= { pingCompliances 3 }
-
- pingCompliance MODULE-COMPLIANCE
- STATUS deprecated
- DESCRIPTION
- "The compliance statement for the DISMAN-PING-MIB. This
- compliance statement has been deprecated because the
- group pingGroup and the pingTimeStampGroup have been
- split and deprecated. The pingFullCompliance statement
- is semantically identical to the deprecated
- pingCompliance statement."
-
- MODULE -- this module
- MANDATORY-GROUPS {
- pingGroup,
- pingNotificationsGroup
- }
- GROUP pingTimeStampGroup
- DESCRIPTION
- "This group is mandatory for implementations that have
- access to a system clock and that are capable of setting
- the values for DateAndTime objects. It is RECOMMENDED
- that when this group is not supported the values
- for the objects in this group be reported as
- '0000000000000000'H."
-
- OBJECT pingMaxConcurrentRequests
- MIN-ACCESS read-only
- DESCRIPTION
- "The agent is not required to support set
- operations to this object."
-
- OBJECT pingCtlStorageType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. It is also allowed
- that implementations support only the volatile
- StorageType enumeration."
-
- OBJECT pingCtlType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. In addition, the only
- value that MUST be supported by an implementation is
- pingIcmpEcho."
-
- OBJECT pingCtlByPassRouteTable
- MIN-ACCESS read-only
- DESCRIPTION
- "This object is not required by implementations that
- are not capable of its implementation. The function
- represented by this object is implementable if the
- setsockopt SOL_SOCKET SO_DONTROUTE option is
- supported."
-
- OBJECT pingCtlSourceAddressType
- SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
- MIN-ACCESS read-only
- DESCRIPTION
- "This object is not required by implementations that
- are not capable of binding the send socket with a
- source address. An implementation is only required to
- support IPv4 and IPv6 addresses."
-
- OBJECT pingCtlSourceAddress
- SYNTAX InetAddress (SIZE(0|4|16))
- MIN-ACCESS read-only
- DESCRIPTION
- "This object is not required by implementations that
- are not capable of binding the send socket with a
- source address. An implementation is only required to
- support IPv4 and globally unique IPv6 addresses."
-
- OBJECT pingCtlIfIndex
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. When write access is
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingCtlDSField
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required. When write access is
- not supported, return a 0 as the value of this object.
- A value of 0 means that the function represented by
- this option is not supported."
-
- OBJECT pingResultsIpTargetAddressType
- SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
- DESCRIPTION
- "An implementation is only required to
- support IPv4 and IPv6 addresses."
-
- OBJECT pingResultsIpTargetAddress
- SYNTAX InetAddress (SIZE(0|4|16))
- DESCRIPTION
- "An implementation is only required to
- support IPv4 and globally unique IPv6 addresses."
- ::= { pingCompliances 1 }
-
- -- MIB groupings
-
- pingMinimumGroup OBJECT-GROUP
- OBJECTS {
- pingMaxConcurrentRequests,
- pingCtlTargetAddressType,
- pingCtlTargetAddress,
- pingCtlDataSize,
- pingCtlTimeOut,
- pingCtlProbeCount,
- pingCtlAdminStatus,
- pingCtlDataFill,
- pingCtlFrequency,
- pingCtlMaxRows,
- pingCtlStorageType,
- pingCtlTrapGeneration,
- pingCtlTrapProbeFailureFilter,
- pingCtlTrapTestFailureFilter,
- pingCtlType,
- pingCtlDescr,
- pingCtlByPassRouteTable,
- pingCtlSourceAddressType,
- pingCtlSourceAddress,
- pingCtlIfIndex,
- pingCtlDSField,
- pingResultsOperStatus,
- pingResultsIpTargetAddressType,
- pingResultsIpTargetAddress,
- pingResultsMinRtt,
- pingResultsMaxRtt,
- pingResultsAverageRtt,
- pingResultsProbeResponses,
- pingResultsSentProbes,
- pingResultsRttSumOfSquares,
- pingResultsLastGoodProbe
- }
- STATUS current
- DESCRIPTION
- "The group of objects that constitute the remote ping
- capability."
- ::= { pingGroups 4 }
-
- pingCtlRowStatusGroup OBJECT-GROUP
- OBJECTS {
- pingCtlRowStatus
- }
- STATUS current
- DESCRIPTION
- "The RowStatus object of the pingCtlTable."
- ::= { pingGroups 5 }
-
- pingHistoryGroup OBJECT-GROUP
- OBJECTS {
- pingProbeHistoryResponse,
- pingProbeHistoryStatus,
- pingProbeHistoryLastRC,
- pingProbeHistoryTime
- }
- STATUS current
- DESCRIPTION
- "The group of objects that constitute the history
- capability."
- ::= { pingGroups 6 }
-
- pingNotificationsGroup NOTIFICATION-GROUP
- NOTIFICATIONS {
- pingProbeFailed,
- pingTestFailed,
- pingTestCompleted
- }
- STATUS current
- DESCRIPTION
- "The notification that are required to be supported by
- implementations of this MIB."
- ::= { pingGroups 3 }
-
- pingGroup OBJECT-GROUP
- OBJECTS {
- pingMaxConcurrentRequests,
- pingCtlTargetAddressType,
- pingCtlTargetAddress,
- pingCtlDataSize,
- pingCtlTimeOut,
- pingCtlProbeCount,
- pingCtlAdminStatus,
- pingCtlDataFill,
- pingCtlFrequency,
- pingCtlMaxRows,
- pingCtlStorageType,
- pingCtlTrapGeneration,
- pingCtlTrapProbeFailureFilter,
- pingCtlTrapTestFailureFilter,
- pingCtlType,
- pingCtlDescr,
- pingCtlByPassRouteTable,
- pingCtlSourceAddressType,
- pingCtlSourceAddress,
- pingCtlIfIndex,
- pingCtlDSField,
- pingCtlRowStatus,
- pingResultsOperStatus,
- pingResultsIpTargetAddressType,
- pingResultsIpTargetAddress,
- pingResultsMinRtt,
- pingResultsMaxRtt,
- pingResultsAverageRtt,
- pingResultsProbeResponses,
- pingResultsSentProbes,
- pingResultsRttSumOfSquares,
- pingProbeHistoryResponse,
- pingProbeHistoryStatus,
- pingProbeHistoryLastRC
- }
- STATUS deprecated
- DESCRIPTION
- "The group of objects that constitute the remote ping
- capability."
- ::= { pingGroups 1 }
-
- pingTimeStampGroup OBJECT-GROUP
-
- OBJECTS {
- pingResultsLastGoodProbe,
- pingProbeHistoryTime
- }
- STATUS deprecated
- DESCRIPTION
- "The group of DateAndTime objects."
- ::= { pingGroups 2 }
-
-END