diff --git a/data/mibs/NOTIFICATION-LOG-MIB.txt b/data/mibs/NOTIFICATION-LOG-MIB.txt
new file mode 100644
index 000000000..c7da93465
--- /dev/null
+++ b/data/mibs/NOTIFICATION-LOG-MIB.txt
@@ -0,0 +1,753 @@
+NOTIFICATION-LOG-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ Integer32, Unsigned32,
+ TimeTicks, Counter32, Counter64,
+ IpAddress, Opaque, mib-2 FROM SNMPv2-SMI
+ TimeStamp, DateAndTime,
+ StorageType, RowStatus,
+ TAddress, TDomain FROM SNMPv2-TC
+ SnmpAdminString, SnmpEngineID FROM SNMP-FRAMEWORK-MIB
+ MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF;
+
+notificationLogMIB MODULE-IDENTITY
+ LAST-UPDATED "200011270000Z" -- 27 November 2000
+ ORGANIZATION "IETF Distributed Management Working Group"
+ CONTACT-INFO "Ramanathan Kavasseri
+ Cisco Systems, Inc.
+ 170 West Tasman Drive,
+ San Jose CA 95134-1706.
+ Phone: +1 408 527 2446
+ Email: ramk@cisco.com"
+ DESCRIPTION
+ "The MIB module for logging SNMP Notifications, that is, Traps
+
+ and Informs."
+-- Revision History
+
+ REVISION "200011270000Z" -- 27 November 2000
+ DESCRIPTION "This is the initial version of this MIB.
+ Published as RFC 3014"
+ ::= { mib-2 92 }
+
+notificationLogMIBObjects OBJECT IDENTIFIER ::= { notificationLogMIB 1 }
+
+nlmConfig OBJECT IDENTIFIER ::= { notificationLogMIBObjects 1 }
+nlmStats OBJECT IDENTIFIER ::= { notificationLogMIBObjects 2 }
+nlmLog OBJECT IDENTIFIER ::= { notificationLogMIBObjects 3 }
+
+--
+-- Configuration Section
+--
+
+nlmConfigGlobalEntryLimit OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of notification entries that may be held
+ in nlmLogTable for all nlmLogNames added together. A particular
+ setting does not guarantee that much data can be held.
+
+ If an application changes the limit while there are
+ Notifications in the log, the oldest Notifications MUST be
+ discarded to bring the log down to the new limit - thus the
+ value of nlmConfigGlobalEntryLimit MUST take precedence over
+ the values of nlmConfigGlobalAgeOut and nlmConfigLogEntryLimit,
+ even if the Notification being discarded has been present for
+ fewer minutes than the value of nlmConfigGlobalAgeOut, or if
+ the named log has fewer entries than that specified in
+ nlmConfigLogEntryLimit.
+
+ A value of 0 means no limit.
+
+ Please be aware that contention between multiple managers
+ trying to set this object to different values MAY affect the
+ reliability and completeness of data seen by each manager."
+ DEFVAL { 0 }
+ ::= { nlmConfig 1 }
+
+nlmConfigGlobalAgeOut OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "minutes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of minutes a Notification SHOULD be kept in a log
+ before it is automatically removed.
+
+ If an application changes the value of nlmConfigGlobalAgeOut,
+ Notifications older than the new time MAY be discarded to meet the
+ new time.
+
+ A value of 0 means no age out.
+
+ Please be aware that contention between multiple managers
+ trying to set this object to different values MAY affect the
+ reliability and completeness of data seen by each manager."
+ DEFVAL { 1440 } -- 24 hours
+ ::= { nlmConfig 2 }
+
+--
+-- Basic Log Configuration Table
+--
+
+nlmConfigLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NlmConfigLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of logging control entries."
+ ::= { nlmConfig 3 }
+
+nlmConfigLogEntry OBJECT-TYPE
+ SYNTAX NlmConfigLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A logging control entry. Depending on the entry's storage type
+ entries may be supplied by the system or created and deleted by
+ applications using nlmConfigLogEntryStatus."
+ INDEX { nlmLogName }
+ ::= { nlmConfigLogTable 1 }
+
+NlmConfigLogEntry ::= SEQUENCE {
+ nlmLogName SnmpAdminString,
+ nlmConfigLogFilterName SnmpAdminString,
+ nlmConfigLogEntryLimit Unsigned32,
+ nlmConfigLogAdminStatus INTEGER,
+ nlmConfigLogOperStatus INTEGER,
+ nlmConfigLogStorageType StorageType,
+ nlmConfigLogEntryStatus RowStatus
+ }
+
+nlmLogName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE(0..32))
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The name of the log.
+
+ An implementation may allow multiple named logs, up to some
+ implementation-specific limit (which may be none). A
+ zero-length log name is reserved for creation and deletion by
+ the managed system, and MUST be used as the default log name by
+ systems that do not support named logs."
+ ::= { nlmConfigLogEntry 1 }
+
+nlmConfigLogFilterName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE(0..32))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A value of snmpNotifyFilterProfileName as used as an index
+ into the snmpNotifyFilterTable in the SNMP Notification MIB,
+ specifying the locally or remotely originated Notifications
+ to be filtered out and not logged in this log.
+
+ A zero-length value or a name that does not identify an
+ existing entry in snmpNotifyFilterTable indicate no
+ Notifications are to be logged in this log."
+ DEFVAL { ''H }
+ ::= { nlmConfigLogEntry 2 }
+
+nlmConfigLogEntryLimit OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The maximum number of notification entries that can be held in
+ nlmLogTable for this named log. A particular setting does not
+ guarantee that that much data can be held.
+
+ If an application changes the limit while there are
+ Notifications in the log, the oldest Notifications are discarded
+ to bring the log down to the new limit.
+
+ A value of 0 indicates no limit.
+
+ Please be aware that contention between multiple managers
+ trying to set this object to different values MAY affect the
+ reliability and completeness of data seen by each manager."
+ DEFVAL { 0 }
+ ::= { nlmConfigLogEntry 3 }
+
+nlmConfigLogAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Control to enable or disable the log without otherwise
+ disturbing the log's entry.
+
+ Please be aware that contention between multiple managers
+ trying to set this object to different values MAY affect the
+ reliability and completeness of data seen by each manager."
+ DEFVAL { enabled }
+ ::= { nlmConfigLogEntry 4 }
+
+nlmConfigLogOperStatus OBJECT-TYPE
+ SYNTAX INTEGER { disabled(1), operational(2), noFilter(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational status of this log:
+
+ disabled administratively disabled
+
+ operational administratively enabled and working
+
+ noFilter administratively enabled but either
+ nlmConfigLogFilterName is zero length
+ or does not name an existing entry in
+ snmpNotifyFilterTable"
+ ::= { nlmConfigLogEntry 5 }
+
+nlmConfigLogStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The storage type of this conceptual row."
+ ::= { nlmConfigLogEntry 6 }
+
+nlmConfigLogEntryStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Control for creating and deleting entries. Entries may be
+ modified while active.
+
+ For non-null-named logs, the managed system records the security
+ credentials from the request that sets nlmConfigLogStatus
+ to 'active' and uses that identity to apply access control to
+ the objects in the Notification to decide if that Notification
+ may be logged."
+ ::= { nlmConfigLogEntry 7 }
+
+--
+-- Statistics Section
+--
+
+nlmStatsGlobalNotificationsLogged OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "notifications"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Notifications put into the nlmLogTable. This
+ counts a Notification once for each log entry, so a Notification
+ put into multiple logs is counted multiple times."
+ ::= { nlmStats 1 }
+
+nlmStatsGlobalNotificationsBumped OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "notifications"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of log entries discarded to make room for a new entry
+ due to lack of resources or the value of nlmConfigGlobalEntryLimit
+ or nlmConfigLogEntryLimit. This does not include entries discarded
+ due to the value of nlmConfigGlobalAgeOut."
+ ::= { nlmStats 2 }
+
+--
+-- Log Statistics Table
+--
+
+nlmStatsLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NlmStatsLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of Notification log statistics entries."
+ ::= { nlmStats 3 }
+
+nlmStatsLogEntry OBJECT-TYPE
+ SYNTAX NlmStatsLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Notification log statistics entry."
+ AUGMENTS { nlmConfigLogEntry }
+ ::= { nlmStatsLogTable 1 }
+
+NlmStatsLogEntry ::= SEQUENCE {
+ nlmStatsLogNotificationsLogged Counter32,
+ nlmStatsLogNotificationsBumped Counter32
+}
+
+nlmStatsLogNotificationsLogged OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "notifications"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Notifications put in this named log."
+ ::= { nlmStatsLogEntry 1 }
+
+nlmStatsLogNotificationsBumped OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "notifications"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of log entries discarded from this named log to make
+ room for a new entry due to lack of resources or the value of
+ nlmConfigGlobalEntryLimit or nlmConfigLogEntryLimit. This does not
+ include entries discarded due to the value of
+ nlmConfigGlobalAgeOut."
+ ::= { nlmStatsLogEntry 2 }
+
+--
+-- Log Section
+--
+
+--
+-- Log Table
+
+--
+
+nlmLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NlmLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of Notification log entries.
+
+ It is an implementation-specific matter whether entries in this
+ table are preserved across initializations of the management
+ system. In general one would expect that they are not.
+
+ Note that keeping entries across initializations of the
+ management system leads to some confusion with counters and
+ TimeStamps, since both of those are based on sysUpTime, which
+ resets on management initialization. In this situation,
+ counters apply only after the reset and nlmLogTime for entries
+ made before the reset MUST be set to 0."
+ ::= { nlmLog 1 }
+
+nlmLogEntry OBJECT-TYPE
+ SYNTAX NlmLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Notification log entry.
+
+ Entries appear in this table when Notifications occur and pass
+ filtering by nlmConfigLogFilterName and access control. They are
+ removed to make way for new entries due to lack of resources or
+ the values of nlmConfigGlobalEntryLimit, nlmConfigGlobalAgeOut, or
+ nlmConfigLogEntryLimit.
+
+ If adding an entry would exceed nlmConfigGlobalEntryLimit or system
+ resources in general, the oldest entry in any log SHOULD be removed
+ to make room for the new one.
+
+ If adding an entry would exceed nlmConfigLogEntryLimit the oldest
+ entry in that log SHOULD be removed to make room for the new one.
+
+ Before the managed system puts a locally-generated Notification
+ into a non-null-named log it assures that the creator of the log
+ has access to the information in the Notification. If not it
+ does not log that Notification in that log."
+ INDEX { nlmLogName, nlmLogIndex }
+ ::= { nlmLogTable 1 }
+
+NlmLogEntry ::= SEQUENCE {
+ nlmLogIndex Unsigned32,
+ nlmLogTime TimeStamp,
+ nlmLogDateAndTime DateAndTime,
+ nlmLogEngineID SnmpEngineID,
+ nlmLogEngineTAddress TAddress,
+ nlmLogEngineTDomain TDomain,
+ nlmLogContextEngineID SnmpEngineID,
+ nlmLogContextName SnmpAdminString,
+ nlmLogNotificationID OBJECT IDENTIFIER
+}
+
+nlmLogIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A monotonically increasing integer for the sole purpose of
+ indexing entries within the named log. When it reaches the
+ maximum value, an extremely unlikely event, the agent wraps the
+ value back to 1."
+ ::= { nlmLogEntry 1 }
+
+nlmLogTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the entry was placed in the log. If
+ the entry occurred before the most recent management system
+ initialization this object value MUST be set to zero."
+ ::= { nlmLogEntry 2 }
+
+nlmLogDateAndTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The local date and time when the entry was logged, instantiated
+ only by systems that have date and time capability."
+ ::= { nlmLogEntry 3 }
+
+nlmLogEngineID OBJECT-TYPE
+ SYNTAX SnmpEngineID
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identification of the SNMP engine at which the Notification
+
+ originated.
+
+ If the log can contain Notifications from only one engine
+ or the Trap is in SNMPv1 format, this object is a zero-length
+ string."
+ ::= { nlmLogEntry 4 }
+
+nlmLogEngineTAddress OBJECT-TYPE
+ SYNTAX TAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transport service address of the SNMP engine from which the
+ Notification was received, formatted according to the corresponding
+ value of nlmLogEngineTDomain. This is used to identify the source
+ of an SNMPv1 trap, since an nlmLogEngineId cannot be extracted
+ from the SNMPv1 trap pdu.
+
+ This object MUST always be instantiated, even if the log
+ can contain Notifications from only one engine.
+
+ Please be aware that the nlmLogEngineTAddress may not uniquely
+ identify the SNMP engine from which the Notification was received.
+ For example, if an SNMP engine uses DHCP or NAT to obtain
+ ip addresses, the address it uses may be shared with other
+ network devices, and hence will not uniquely identify the
+ SNMP engine."
+ ::= { nlmLogEntry 5 }
+
+nlmLogEngineTDomain OBJECT-TYPE
+ SYNTAX TDomain
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the kind of transport service by which a Notification
+ was received from an SNMP engine. nlmLogEngineTAddress contains
+ the transport service address of the SNMP engine from which
+ this Notification was received.
+
+ Possible values for this object are presently found in the
+ Transport Mappings for SNMPv2 document (RFC 1906 [8])."
+ ::= { nlmLogEntry 6 }
+
+nlmLogContextEngineID OBJECT-TYPE
+ SYNTAX SnmpEngineID
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the Notification was received in a protocol which has a
+ contextEngineID element like SNMPv3, this object has that value.
+ Otherwise its value is a zero-length string."
+ ::= { nlmLogEntry 7 }
+
+nlmLogContextName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the SNMP MIB context from which the Notification came.
+ For SNMPv1 Traps this is the community string from the Trap."
+ ::= { nlmLogEntry 8 }
+
+nlmLogNotificationID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The NOTIFICATION-TYPE object identifier of the Notification that
+ occurred."
+ ::= { nlmLogEntry 9 }
+
+--
+-- Log Variable Table
+--
+
+nlmLogVariableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NlmLogVariableEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of variables to go with Notification log entries."
+ ::= { nlmLog 2 }
+
+nlmLogVariableEntry OBJECT-TYPE
+ SYNTAX NlmLogVariableEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Notification log entry variable.
+
+ Entries appear in this table when there are variables in
+ the varbind list of a Notification in nlmLogTable."
+ INDEX { nlmLogName, nlmLogIndex, nlmLogVariableIndex }
+ ::= { nlmLogVariableTable 1 }
+
+NlmLogVariableEntry ::= SEQUENCE {
+
+ nlmLogVariableIndex Unsigned32,
+ nlmLogVariableID OBJECT IDENTIFIER,
+ nlmLogVariableValueType INTEGER,
+ nlmLogVariableCounter32Val Counter32,
+ nlmLogVariableUnsigned32Val Unsigned32,
+ nlmLogVariableTimeTicksVal TimeTicks,
+ nlmLogVariableInteger32Val Integer32,
+ nlmLogVariableOctetStringVal OCTET STRING,
+ nlmLogVariableIpAddressVal IpAddress,
+ nlmLogVariableOidVal OBJECT IDENTIFIER,
+ nlmLogVariableCounter64Val Counter64,
+ nlmLogVariableOpaqueVal Opaque
+}
+
+nlmLogVariableIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A monotonically increasing integer, starting at 1 for a given
+ nlmLogIndex, for indexing variables within the logged
+ Notification."
+ ::= { nlmLogVariableEntry 1 }
+
+nlmLogVariableID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The variable's object identifier."
+ ::= { nlmLogVariableEntry 2 }
+
+nlmLogVariableValueType OBJECT-TYPE
+ SYNTAX INTEGER { counter32(1), unsigned32(2), timeTicks(3),
+ integer32(4), ipAddress(5), octetString(6),
+ objectId(7), counter64(8), opaque(9) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the value. One and only one of the value
+ objects that follow must be instantiated, based on this type."
+ ::= { nlmLogVariableEntry 3 }
+
+nlmLogVariableCounter32Val OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'counter32'."
+ ::= { nlmLogVariableEntry 4 }
+
+nlmLogVariableUnsigned32Val OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'unsigned32'."
+ ::= { nlmLogVariableEntry 5 }
+
+nlmLogVariableTimeTicksVal OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'timeTicks'."
+ ::= { nlmLogVariableEntry 6 }
+
+nlmLogVariableInteger32Val OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'integer32'."
+ ::= { nlmLogVariableEntry 7 }
+
+nlmLogVariableOctetStringVal OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'octetString'."
+ ::= { nlmLogVariableEntry 8 }
+
+nlmLogVariableIpAddressVal OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'ipAddress'.
+ Although this seems to be unfriendly for IPv6, we
+ have to recognize that there are a number of older
+ MIBs that do contain an IPv4 format address, known
+ as IpAddress.
+
+ IPv6 addresses are represented using TAddress or
+ InetAddress, and so the underlying datatype is
+
+ OCTET STRING, and their value would be stored in
+ the nlmLogVariableOctetStringVal column."
+ ::= { nlmLogVariableEntry 9 }
+
+nlmLogVariableOidVal OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'objectId'."
+ ::= { nlmLogVariableEntry 10 }
+
+nlmLogVariableCounter64Val OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'counter64'."
+ ::= { nlmLogVariableEntry 11 }
+
+nlmLogVariableOpaqueVal OBJECT-TYPE
+ SYNTAX Opaque
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when nlmLogVariableType is 'opaque'."
+ ::= { nlmLogVariableEntry 12 }
+
+--
+-- Conformance
+--
+
+notificationLogMIBConformance OBJECT IDENTIFIER ::=
+ { notificationLogMIB 3 }
+notificationLogMIBCompliances OBJECT IDENTIFIER ::=
+ { notificationLogMIBConformance 1 }
+notificationLogMIBGroups OBJECT IDENTIFIER ::=
+ { notificationLogMIBConformance 2 }
+
+-- Compliance
+
+notificationLogMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities which implement
+ the Notification Log MIB."
+ MODULE -- this module
+
+ MANDATORY-GROUPS {
+ notificationLogConfigGroup,
+ notificationLogStatsGroup,
+ notificationLogLogGroup
+ }
+
+ OBJECT nlmConfigGlobalEntryLimit
+ SYNTAX Unsigned32 (0..4294967295)
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Implementations may choose a limit and not allow it to be
+ changed or may enforce an upper or lower bound on the
+ limit."
+
+ OBJECT nlmConfigLogEntryLimit
+ SYNTAX Unsigned32 (0..4294967295)
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Implementations may choose a limit and not allow it to be
+ changed or may enforce an upper or lower bound on the
+ limit."
+
+ OBJECT nlmConfigLogEntryStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Implementations may disallow the creation of named logs."
+
+ GROUP notificationLogDateGroup
+ DESCRIPTION
+ "This group is mandatory on systems that keep wall clock
+ date and time and should not be implemented on systems that
+ do not have a wall clock date."
+ ::= { notificationLogMIBCompliances 1 }
+
+-- Units of Conformance
+
+notificationLogConfigGroup OBJECT-GROUP
+ OBJECTS {
+ nlmConfigGlobalEntryLimit,
+ nlmConfigGlobalAgeOut,
+ nlmConfigLogFilterName,
+ nlmConfigLogEntryLimit,
+ nlmConfigLogAdminStatus,
+ nlmConfigLogOperStatus,
+ nlmConfigLogStorageType,
+ nlmConfigLogEntryStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "Notification log configuration management."
+ ::= { notificationLogMIBGroups 1 }
+
+notificationLogStatsGroup OBJECT-GROUP
+ OBJECTS {
+ nlmStatsGlobalNotificationsLogged,
+ nlmStatsGlobalNotificationsBumped,
+ nlmStatsLogNotificationsLogged,
+ nlmStatsLogNotificationsBumped
+ }
+ STATUS current
+ DESCRIPTION
+ "Notification log statistics."
+ ::= { notificationLogMIBGroups 2 }
+
+notificationLogLogGroup OBJECT-GROUP
+ OBJECTS {
+ nlmLogTime,
+ nlmLogEngineID,
+ nlmLogEngineTAddress,
+ nlmLogEngineTDomain,
+ nlmLogContextEngineID,
+ nlmLogContextName,
+ nlmLogNotificationID,
+ nlmLogVariableID,
+ nlmLogVariableValueType,
+ nlmLogVariableCounter32Val,
+ nlmLogVariableUnsigned32Val,
+ nlmLogVariableTimeTicksVal,
+ nlmLogVariableInteger32Val,
+ nlmLogVariableOctetStringVal,
+ nlmLogVariableIpAddressVal,
+ nlmLogVariableOidVal,
+ nlmLogVariableCounter64Val,
+ nlmLogVariableOpaqueVal
+ }
+ STATUS current
+ DESCRIPTION
+ "Notification log data."
+ ::= { notificationLogMIBGroups 3 }
+
+notificationLogDateGroup OBJECT-GROUP
+ OBJECTS {
+ nlmLogDateAndTime
+ }
+ STATUS current
+ DESCRIPTION
+ "Conditionally mandatory notification log data.
+ This group is mandatory on systems that keep wall
+ clock date and time and should not be implemented
+ on systems that do not have a wall clock date."
+ ::= { notificationLogMIBGroups 4 }
+
+END