diff options
Diffstat (limited to 'mibs/DISMAN-PING-MIB.txt')
-rw-r--r-- | mibs/DISMAN-PING-MIB.txt | 1561 |
1 files changed, 1561 insertions, 0 deletions
diff --git a/mibs/DISMAN-PING-MIB.txt b/mibs/DISMAN-PING-MIB.txt new file mode 100644 index 000000000..645ff8c7d --- /dev/null +++ b/mibs/DISMAN-PING-MIB.txt @@ -0,0 +1,1561 @@ +DISMAN-PING-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Integer32, + Unsigned32, Gauge32, mib-2, + NOTIFICATION-TYPE, OBJECT-IDENTITY + FROM SNMPv2-SMI -- RFC2578 + TEXTUAL-CONVENTION, RowStatus, + StorageType, DateAndTime, TruthValue + FROM SNMPv2-TC -- RFC2579 + MODULE-COMPLIANCE, OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF -- RFC2580 + InterfaceIndexOrZero -- RFC2863 + FROM IF-MIB + SnmpAdminString + FROM SNMP-FRAMEWORK-MIB -- RFC3411 + InetAddressType, InetAddress + FROM INET-ADDRESS-MIB; -- RFC4001 + + pingMIB MODULE-IDENTITY + LAST-UPDATED "200606130000Z" -- 13 June 2006 + ORGANIZATION "IETF Distributed Management Working Group" + CONTACT-INFO + "Juergen Quittek + + NEC Europe Ltd. + Network Laboratories + Kurfuersten-Anlage 36 + 69115 Heidelberg + Germany + + Phone: +49 6221 4342-115 + + Email: quittek@netlab.nec.de" + DESCRIPTION + "The Ping MIB (DISMAN-PING-MIB) provides the capability of + controlling the use of the ping function at a remote + host. + + Copyright (C) The Internet Society (2006). This version of + this MIB module is part of RFC 4560; see the RFC itself for + full legal notices." + + -- Revision history + + REVISION "200606130000Z" -- 13 June 2006 + DESCRIPTION + "Updated version, published as RFC 4560. + - Correctly considered IPv6 in DESCRIPTION + clause of pingCtlDataSize + - Replaced references to RFC 2575 by RFC 3415 + - Replaced references to RFC 2571 by RFC 3411 + - Replaced references to RFC 2851 by RFC 4001 + - Added DEFVAL { {} } to definition of + pingCtlTrapGeneration + - Changed DEFVAL of object pingCtlDescr from + DEFVAL { '00'H } to DEFVAL { ''H } + - Changed DEFVAL of object pingCtlSourceAddressType + from DEFVAL { ipv4 } to DEFVAL { unknown } + - Extended DESCRIPTION clause of pingResultsTable + describing re-initialization of entries + - Changed SYNTAX of pingResultsProbeResponses and + pingResultsSentProbes from Unsigned32 to Gauge32 + - Changed status of pingCompliance to deprecated + - Added pingFullCompliance and pingMinimumCompliance + - Changed status of pingGroup and pingTimeStampGroup + to deprecated + - Added pingMinimumGroup, pingCtlRowStatusGroup, + and pingHistoryGroup" + + REVISION "200009210000Z" -- 21 September 2000 + DESCRIPTION + "Initial version, published as RFC 2925." + ::= { mib-2 80 } + + -- Textual Conventions + + OperationResponseStatus ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Used to report the result of an operation: + + responseReceived(1) - Operation is completed successfully. + unknown(2) - Operation failed due to unknown error. + internalError(3) - An implementation detected an error + in its own processing that caused an operation + to fail. + requestTimedOut(4) - Operation failed to receive a + valid reply within the time limit imposed on it. + unknownDestinationAddress(5) - Invalid destination + address. + noRouteToTarget(6) - Could not find a route to target. + interfaceInactiveToTarget(7) - The interface to be + used in sending a probe is inactive, and an + alternate route does not exist. + arpFailure(8) - Unable to resolve a target address to a + media-specific address. + maxConcurrentLimitReached(9) - The maximum number of + concurrent active operations would have been exceeded + if the corresponding operation was allowed. + unableToResolveDnsName(10) - The DNS name specified was + unable to be mapped to an IP address. + invalidHostAddress(11) - The IP address for a host + has been determined to be invalid. Examples of this + are broadcast or multicast addresses." + SYNTAX INTEGER { + responseReceived(1), + unknown(2), + internalError(3), + requestTimedOut(4), + unknownDestinationAddress(5), + noRouteToTarget(6), + interfaceInactiveToTarget(7), + arpFailure(8), + maxConcurrentLimitReached(9), + unableToResolveDnsName(10), + invalidHostAddress(11) + } + + -- Top level structure of the MIB + + pingNotifications OBJECT IDENTIFIER ::= { pingMIB 0 } + pingObjects OBJECT IDENTIFIER ::= { pingMIB 1 } + pingConformance OBJECT IDENTIFIER ::= { pingMIB 2 } + + -- The registration node (point) for ping implementation types + + pingImplementationTypeDomains OBJECT IDENTIFIER ::= { pingMIB 3 } + + pingIcmpEcho OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indicates that an implementation is using the Internet + Control Message Protocol (ICMP) 'ECHO' facility." + ::= { pingImplementationTypeDomains 1 } + + pingUdpEcho OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indicates that an implementation is using the UDP echo + port (7)." + REFERENCE + "RFC 862, 'Echo Protocol'." + ::= { pingImplementationTypeDomains 2 } + + pingSnmpQuery OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indicates that an implementation is using an SNMP query + to calculate a round trip time." + ::= { pingImplementationTypeDomains 3 } + + pingTcpConnectionAttempt OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indicates that an implementation is attempting to + connect to a TCP port in order to calculate a round + trip time." + ::= { pingImplementationTypeDomains 4 } + + -- Simple Object Definitions + + pingMaxConcurrentRequests OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "requests" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum number of concurrent active ping requests + that are allowed within an agent implementation. A value + of 0 for this object implies that there is no limit for + the number of concurrent active requests in effect. + + The limit applies only to new requests being activated. + When a new value is set, the agent will continue processing + all the requests already active, even if their number + exceeds the limit just imposed." + DEFVAL { 10 } + ::= { pingObjects 1 } + + -- Ping Control Table + + pingCtlTable OBJECT-TYPE + SYNTAX SEQUENCE OF PingCtlEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Defines the ping Control Table for providing, via SNMP, + the capability of performing ping operations at + a remote host. The results of these operations are + stored in the pingResultsTable and the + pingProbeHistoryTable." + ::= { pingObjects 2 } + + pingCtlEntry OBJECT-TYPE + SYNTAX PingCtlEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Defines an entry in the pingCtlTable. The first index + element, pingCtlOwnerIndex, is of type SnmpAdminString, + a textual convention that allows for use of the SNMPv3 + View-Based Access Control Model (RFC 3415, VACM) + and that allows a management application to identify its + entries. The second index, pingCtlTestName (also an + SnmpAdminString), enables the same management + application to have multiple outstanding requests." + INDEX { + pingCtlOwnerIndex, + pingCtlTestName + } + ::= { pingCtlTable 1 } + + PingCtlEntry ::= + SEQUENCE { + pingCtlOwnerIndex SnmpAdminString, + pingCtlTestName SnmpAdminString, + pingCtlTargetAddressType InetAddressType, + pingCtlTargetAddress InetAddress, + pingCtlDataSize Unsigned32, + pingCtlTimeOut Unsigned32, + pingCtlProbeCount Unsigned32, + pingCtlAdminStatus INTEGER, + pingCtlDataFill OCTET STRING, + pingCtlFrequency Unsigned32, + pingCtlMaxRows Unsigned32, + pingCtlStorageType StorageType, + pingCtlTrapGeneration BITS, + pingCtlTrapProbeFailureFilter Unsigned32, + pingCtlTrapTestFailureFilter Unsigned32, + pingCtlType OBJECT IDENTIFIER, + pingCtlDescr SnmpAdminString, + pingCtlSourceAddressType InetAddressType, + pingCtlSourceAddress InetAddress, + pingCtlIfIndex InterfaceIndexOrZero, + pingCtlByPassRouteTable TruthValue, + pingCtlDSField Unsigned32, + pingCtlRowStatus RowStatus + } + + pingCtlOwnerIndex OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE(0..32)) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "To facilitate the provisioning of access control by a + security administrator using the View-Based Access + Control Model (RFC 2575, VACM) for tables in which + multiple users may need to create or + modify entries independently, the initial index is used + as an 'owner index'. Such an initial index has a syntax + of SnmpAdminString and can thus be trivially mapped to a + securityName or groupName defined in VACM, in + accordance with a security policy. + + When used in conjunction with such a security policy, all + entries in the table belonging to a particular user (or + group) will have the same value for this initial index. + For a given user's entries in a particular table, the + object identifiers for the information in these entries + will have the same subidentifiers (except for the 'column' + subidentifier) up to the end of the encoded owner index. + To configure VACM to permit access to this portion of the + table, one would create vacmViewTreeFamilyTable entries + with the value of vacmViewTreeFamilySubtree including + the owner index portion, and vacmViewTreeFamilyMask + 'wildcarding' the column subidentifier. More elaborate + configurations are possible." + ::= { pingCtlEntry 1 } + + pingCtlTestName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE(0..32)) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The name of the ping test. This is locally unique, within + the scope of a pingCtlOwnerIndex." + ::= { pingCtlEntry 2 } + + pingCtlTargetAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the type of host address to be used at a remote + host for performing a ping operation." + DEFVAL { unknown } + ::= { pingCtlEntry 3 } + + pingCtlTargetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the host address to be used at a remote host for + performing a ping operation. The host address type is + determined by the value of the corresponding + pingCtlTargetAddressType. + + A value for this object MUST be set prior to transitioning + its corresponding pingCtlEntry to active(1) via + pingCtlRowStatus." + DEFVAL { ''H } + ::= { pingCtlEntry 4 } + + pingCtlDataSize OBJECT-TYPE + SYNTAX Unsigned32 (0..65507) + UNITS "octets" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the size of the data portion to be + transmitted in a ping operation, in octets. Whether this + value can be applied depends on the selected + implementation method for performing a ping operation, + indicated by pingCtlType in the same conceptual row. + If the method used allows applying the value contained + + in this object, then it MUST be applied. If the specified + size is not appropriate for the chosen ping method, the + implementation SHOULD use whatever size (appropriate to + the method) is closest to the specified size. + + The maximum value for this object was computed by + subtracting the smallest possible IP header size of + 20 octets (IPv4 header with no options) and the UDP + header size of 8 octets from the maximum IP packet size. + An IP packet has a maximum size of 65535 octets + (excluding IPv6 Jumbograms)." + DEFVAL { 0 } + ::= { pingCtlEntry 5 } + + pingCtlTimeOut OBJECT-TYPE + SYNTAX Unsigned32 (1..60) + UNITS "seconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the time-out value, in seconds, for a + remote ping operation." + DEFVAL { 3 } + ::= { pingCtlEntry 6 } + + pingCtlProbeCount OBJECT-TYPE + SYNTAX Unsigned32 (1..15) + UNITS "probes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the number of times to perform a ping + operation at a remote host as part of a single ping test." + DEFVAL { 1 } + ::= { pingCtlEntry 7 } + + pingCtlAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), -- test should be started + disabled(2) -- test should be stopped + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Reflects the desired state that a pingCtlEntry should be + in: + + enabled(1) - Attempt to activate the test as defined by + this pingCtlEntry. + disabled(2) - Deactivate the test as defined by this + pingCtlEntry. + + Refer to the corresponding pingResultsOperStatus to + determine the operational state of the test defined by + this entry." + DEFVAL { disabled } + ::= { pingCtlEntry 8 } + + pingCtlDataFill OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..1024)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The content of this object is used together with the + corresponding pingCtlDataSize value to determine how to + fill the data portion of a probe packet. The option of + selecting a data fill pattern can be useful when links + are compressed or have data pattern sensitivities. The + contents of pingCtlDataFill should be repeated in a ping + packet when the size of the data portion of the ping + packet is greater than the size of pingCtlDataFill." + DEFVAL { '00'H } + ::= { pingCtlEntry 9 } + + pingCtlFrequency OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "seconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The number of seconds to wait before repeating a ping test + as defined by the value of the various objects in the + corresponding row. + + A single ping test consists of a series of ping probes. + The number of probes is determined by the value of the + corresponding pingCtlProbeCount object. After a single + test is completed the number of seconds as defined by the + value of pingCtlFrequency MUST elapse before the + next ping test is started. + + A value of 0 for this object implies that the test + as defined by the corresponding entry will not be + repeated." + DEFVAL { 0 } + ::= { pingCtlEntry 10 } + + pingCtlMaxRows OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "rows" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The maximum number of corresponding entries allowed + in the pingProbeHistoryTable. An implementation of this + MIB will remove the oldest corresponding entry in the + pingProbeHistoryTable to allow the addition of an + new entry once the number of corresponding rows in the + pingProbeHistoryTable reaches this value. + + Old entries are not removed when a new test is + started. Entries are added to the pingProbeHistoryTable + until pingCtlMaxRows is reached before entries begin to + be removed. + + A value of 0 for this object disables creation of + pingProbeHistoryTable entries." + DEFVAL { 50 } + ::= { pingCtlEntry 11 } + + pingCtlStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The storage type for this conceptual row. + Conceptual rows having the value 'permanent' need not + allow write-access to any columnar objects in the row." + DEFVAL { nonVolatile } + ::= { pingCtlEntry 12 } + + pingCtlTrapGeneration OBJECT-TYPE + SYNTAX BITS { + probeFailure(0), + testFailure(1), + testCompletion(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of this object determines when and whether + to generate a notification for this entry: + + probeFailure(0) - Generate a pingProbeFailed + notification subject to the value of + pingCtlTrapProbeFailureFilter. The object + pingCtlTrapProbeFailureFilter can be used + to specify the number of consecutive probe + failures that are required before a + pingProbeFailed notification can be generated. + testFailure(1) - Generate a pingTestFailed + notification. In this instance the object + pingCtlTrapTestFailureFilter can be used to + determine the number of probe failures that + signal when a test fails. + testCompletion(2) - Generate a pingTestCompleted + notification. + + By default, no bits are set, indicating that + none of the above options is selected." + DEFVAL { {} } -- no bits set. + ::= { pingCtlEntry 13 } + + pingCtlTrapProbeFailureFilter OBJECT-TYPE + SYNTAX Unsigned32 (0..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of this object is used to determine when + to generate a pingProbeFailed NOTIFICATION. + + Setting BIT probeFailure(0) of object + pingCtlTrapGeneration to '1' implies that a + pingProbeFailed NOTIFICATION is generated only when + + a number of consecutive ping probes equal to the + value of pingCtlTrapProbeFailureFilter fail within + a given ping test. After triggering the notification, + the probe failure counter is reset to zero." + DEFVAL { 1 } + ::= { pingCtlEntry 14 } + + pingCtlTrapTestFailureFilter OBJECT-TYPE + SYNTAX Unsigned32 (0..15) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of this object is used to determine when + to generate a pingTestFailed NOTIFICATION. + + Setting BIT testFailure(1) of object + + pingCtlTrapGeneration to '1' implies that a + pingTestFailed NOTIFICATION is generated only when + a number of consecutive ping tests equal to the + value of pingCtlTrapProbeFailureFilter fail. + After triggering the notification, the test failure + counter is reset to zero." + DEFVAL { 1 } + ::= { pingCtlEntry 15 } + + pingCtlType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of this object is used either to report or + to select the implementation method to be used for + calculating a ping response time. The value of this + object MAY be selected from pingImplementationTypeDomains. + + Additional implementation types SHOULD be allocated as + required by implementers of the DISMAN-PING-MIB under + their enterprise-specific registration point and not + beneath pingImplementationTypeDomains." + DEFVAL { pingIcmpEcho } + ::= { pingCtlEntry 16 } + + pingCtlDescr OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The purpose of this object is to provide a + descriptive name of the remote ping test." + DEFVAL { ''H } + ::= { pingCtlEntry 17 } + + pingCtlSourceAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the type of the source address, + pingCtlSourceAddress, to be used at a remote host + when a ping operation is performed." + DEFVAL { unknown } + ::= { pingCtlEntry 18 } + + pingCtlSourceAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Use the specified IP address (which must be given in + numeric form, not as a hostname) as the source address + in outgoing probe packets. On hosts with more than one + IP address, this option can be used to select the address + to be used. If the IP address is not one of this + machine's interface addresses, an error is returned and + nothing is sent. A zero-length octet string value for + this object disables source address specification. + + The address type (InetAddressType) that relates to + this object is specified by the corresponding value + of pingCtlSourceAddressType." + DEFVAL { ''H } + ::= { pingCtlEntry 19 } + + pingCtlIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Setting this object to an interface's ifIndex prior + to starting a remote ping operation directs + the ping probes to be transmitted over the + specified interface. A value of zero for this object + means that this option is not enabled." + DEFVAL { 0 } + ::= { pingCtlEntry 20 } + + pingCtlByPassRouteTable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The purpose of this object is to enable optional + bypassing the route table. If enabled, the remote + host will bypass the normal routing tables and send + directly to a host on an attached network. If the + host is not on a directly attached network, an + error is returned. This option can be used to perform + the ping operation to a local host through an + interface that has no route defined (e.g., after the + interface was dropped by the routing daemon at the host)." + DEFVAL { false } + ::= { pingCtlEntry 21 } + + pingCtlDSField OBJECT-TYPE + SYNTAX Unsigned32 (0..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Specifies the value to store in the Type of Service + (TOS) octet in the IPv4 header or in the Traffic + Class octet in the IPv6 header, respectively, of the + IP packet used to encapsulate the ping probe. + + The octet to be set in the IP header contains the + Differentiated Services (DS) Field in the six most + significant bits. + + This option can be used to determine what effect an + explicit DS Field setting has on a ping response. + Not all values are legal or meaningful. A value of 0 + means that the function represented by this option is + not supported. DS Field usage is often not supported + by IP implementations, and not all values are supported. + Refer to RFC 2474 and RFC 3260 for guidance on usage of + this field." + REFERENCE + "Refer to RFC 1812 for the definition of the IPv4 TOS + octet and to RFC 2460 for the definition of the IPv6 + Traffic Class octet. Refer to RFC 2474 and RFC 3260 + for the definition of the Differentiated Services Field." + DEFVAL { 0 } + ::= { pingCtlEntry 22 } + + pingCtlRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object allows entries to be created and deleted + in the pingCtlTable. Deletion of an entry in this + table results in the deletion of all corresponding (same + pingCtlOwnerIndex and pingCtlTestName index values) + pingResultsTable and pingProbeHistoryTable entries. + + A value MUST be specified for pingCtlTargetAddress + prior to acceptance of a transition to active(1) state. + + When a value for pingCtlTargetAddress is set, + the value of object pingCtlRowStatus changes + from notReady(3) to notInService(2). + + Activation of a remote ping operation is controlled + via pingCtlAdminStatus, not by changing + this object's value to active(1). + + Transitions in and out of active(1) state are not + allowed while an entry's pingResultsOperStatus is + active(1), with the exception that deletion of + an entry in this table by setting its RowStatus + object to destroy(6) will stop an active + ping operation. + + The operational state of a ping operation + can be determined by examination of its + pingResultsOperStatus object." + REFERENCE + "See definition of RowStatus in RFC 2579, 'Textual + Conventions for SMIv2.'" + ::= { pingCtlEntry 23 } + +-- Ping Results Table + + pingResultsTable OBJECT-TYPE + SYNTAX SEQUENCE OF PingResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Defines the Ping Results Table for providing + the capability of performing ping operations at + a remote host. The results of these operations are + stored in the pingResultsTable and the pingProbeHistoryTable. + + An entry is added to the pingResultsTable when an + pingCtlEntry is started by successful transition + of its pingCtlAdminStatus object to enabled(1). + + If the object pingCtlAdminStatus already has the value + enabled(1), and if the corresponding pingResultsOperStatus + object has the value completed(3), then successfully writing + enabled(1) to object pingCtlAdminStatus re-initializes the + already existing entry in the pingResultsTable. The values + of objects in the re-initialized entry are the same as the + values of objects in a new entry would be. + + An entry is removed from the pingResultsTable when + its corresponding pingCtlEntry is deleted." + ::= { pingObjects 3 } + + pingResultsEntry OBJECT-TYPE + SYNTAX PingResultsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Defines an entry in the pingResultsTable. The + pingResultsTable has the same indexing as the + pingCtlTable so that a pingResultsEntry + corresponds to the pingCtlEntry that caused it to + be created." + INDEX { + pingCtlOwnerIndex, + pingCtlTestName + } + ::= { pingResultsTable 1 } + + PingResultsEntry ::= + SEQUENCE { + pingResultsOperStatus INTEGER, + pingResultsIpTargetAddressType InetAddressType, + pingResultsIpTargetAddress InetAddress, + pingResultsMinRtt Unsigned32, + pingResultsMaxRtt Unsigned32, + pingResultsAverageRtt Unsigned32, + pingResultsProbeResponses Gauge32, + pingResultsSentProbes Gauge32, + pingResultsRttSumOfSquares Unsigned32, + pingResultsLastGoodProbe DateAndTime + } + + pingResultsOperStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), -- test is in progress + disabled(2), -- test has stopped + completed(3) -- test is completed + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Reflects the operational state of a pingCtlEntry: + + enabled(1) - Test is active. + disabled(2) - Test has stopped. + completed(3) - Test is completed." + ::= { pingResultsEntry 1 } + + pingResultsIpTargetAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the type of address stored + in the corresponding pingResultsIpTargetAddress + object." + DEFVAL { unknown } + ::= { pingResultsEntry 2 } + + pingResultsIpTargetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reports the IP address associated + with a pingCtlTargetAddress value when the destination + address is specified as a DNS name. The value of + this object should be a zero-length octet string + when a DNS name is not specified or when a + specified DNS name fails to resolve. + + The address type (InetAddressType) that relates to + this object is specified by the corresponding value + of pingResultsIpTargetAddressType." + DEFVAL { ''H } + ::= { pingResultsEntry 3 } + + pingResultsMinRtt OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum ping round-trip-time (RTT) received. A value + of 0 for this object implies that no RTT has been received." + ::= { pingResultsEntry 4 } + + pingResultsMaxRtt OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum ping round-trip-time (RTT) received. A value + of 0 for this object implies that no RTT has been received." + ::= { pingResultsEntry 5 } + + pingResultsAverageRtt OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current average ping round-trip-time (RTT)." + ::= { pingResultsEntry 6 } + + pingResultsProbeResponses OBJECT-TYPE + SYNTAX Gauge32 + UNITS "responses" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of responses received for the corresponding + pingCtlEntry and pingResultsEntry. The value of this object + MUST be reported as 0 when no probe responses have been + received." + ::= { pingResultsEntry 7 } + + pingResultsSentProbes OBJECT-TYPE + SYNTAX Gauge32 + UNITS "probes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object reflects the number of probes sent + for the corresponding pingCtlEntry and pingResultsEntry. + The value of this object MUST be reported as 0 when no probes + have been sent." + ::= { pingResultsEntry 8 } + + pingResultsRttSumOfSquares OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the sum of the squares for all ping + responses received. Its purpose is to enable standard + deviation calculation. The value of this object MUST + be reported as 0 when no ping responses have been + received." + ::= { pingResultsEntry 9 } + + pingResultsLastGoodProbe OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Date and time when the last response was received for + a probe." + ::= { pingResultsEntry 10 } + + -- Ping Probe History Table + + pingProbeHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF PingProbeHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Defines a table for storing the results of ping + operations. The number of entries in this table is + limited per entry in the pingCtlTable by the value + of the corresponding pingCtlMaxRows object. + + An entry in this table is created when the result of + a ping probe is determined. The initial 2 instance + identifier index values identify the pingCtlEntry + that a probe result (pingProbeHistoryEntry) belongs + to. An entry is removed from this table when + its corresponding pingCtlEntry is deleted. + + An implementation of this MIB will remove the oldest + entry in the pingProbeHistoryTable of the + corresponding entry in the pingCtlTable to allow + the addition of an new entry once the number of rows + in the pingProbeHistoryTable reaches the value + specified by pingCtlMaxRows for the corresponding + entry in the pingCtlTable." + ::= { pingObjects 4 } + + pingProbeHistoryEntry OBJECT-TYPE + SYNTAX PingProbeHistoryEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Defines an entry in the pingProbeHistoryTable. + The first two index elements identify the + pingCtlEntry that a pingProbeHistoryEntry belongs + to. The third index element selects a single + probe result." + INDEX { + + pingCtlOwnerIndex, + pingCtlTestName, + pingProbeHistoryIndex + } + ::= { pingProbeHistoryTable 1 } + + PingProbeHistoryEntry ::= + SEQUENCE { + pingProbeHistoryIndex Unsigned32, + pingProbeHistoryResponse Unsigned32, + pingProbeHistoryStatus OperationResponseStatus, + pingProbeHistoryLastRC Integer32, + pingProbeHistoryTime DateAndTime + } + + pingProbeHistoryIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..'ffffffff'h) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in this table is created when the result of + a ping probe is determined. The initial 2 instance + identifier index values identify the pingCtlEntry + that a probe result (pingProbeHistoryEntry) belongs + to. + + An implementation MUST start assigning + pingProbeHistoryIndex values at 1 and wrap after + exceeding the maximum possible value as defined by + the limit of this object ('ffffffff'h)." + ::= { pingProbeHistoryEntry 1 } + + pingProbeHistoryResponse OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of time measured in milliseconds from when + a probe was sent to when its response was received or + when it timed out. The value of this object is reported + as 0 when it is not possible to transmit a probe." + ::= { pingProbeHistoryEntry 2 } + + pingProbeHistoryStatus OBJECT-TYPE + SYNTAX OperationResponseStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The result of a particular probe done by a remote host." + ::= { pingProbeHistoryEntry 3 } + + pingProbeHistoryLastRC OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The last implementation-method-specific reply code received. + If the ICMP Echo capability is being used, then a successful + probe ends when an ICMP response is received that contains + the code ICMP_ECHOREPLY(0). The ICMP codes are maintained + by IANA. Standardized ICMP codes are listed at + http://www.iana.org/assignments/icmp-parameters. + The ICMPv6 codes are listed at + http://www.iana.org/assignments/icmpv6-parameters." + ::= { pingProbeHistoryEntry 4 } + + pingProbeHistoryTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Timestamp for when this probe result was determined." + ::= { pingProbeHistoryEntry 5 } + + -- Notification Definition section + + pingProbeFailed NOTIFICATION-TYPE + OBJECTS { + pingCtlTargetAddressType, + pingCtlTargetAddress, + pingResultsOperStatus, + pingResultsIpTargetAddressType, + pingResultsIpTargetAddress, + pingResultsMinRtt, + pingResultsMaxRtt, + pingResultsAverageRtt, + pingResultsProbeResponses, + pingResultsSentProbes, + pingResultsRttSumOfSquares, + pingResultsLastGoodProbe + } + STATUS current + DESCRIPTION + "Generated when a probe failure is detected, when the + + corresponding pingCtlTrapGeneration object is set to + probeFailure(0), subject to the value of + pingCtlTrapProbeFailureFilter. The object + pingCtlTrapProbeFailureFilter can be used to specify the + number of consecutive probe failures that are required + before this notification can be generated." + ::= { pingNotifications 1 } + + pingTestFailed NOTIFICATION-TYPE + OBJECTS { + pingCtlTargetAddressType, + pingCtlTargetAddress, + pingResultsOperStatus, + pingResultsIpTargetAddressType, + pingResultsIpTargetAddress, + pingResultsMinRtt, + pingResultsMaxRtt, + pingResultsAverageRtt, + pingResultsProbeResponses, + pingResultsSentProbes, + pingResultsRttSumOfSquares, + pingResultsLastGoodProbe + } + STATUS current + DESCRIPTION + "Generated when a ping test is determined to have failed, + when the corresponding pingCtlTrapGeneration object is + set to testFailure(1). In this instance, + pingCtlTrapTestFailureFilter should specify the number of + probes in a test required to have failed in order to + consider the test failed." + ::= { pingNotifications 2 } + + pingTestCompleted NOTIFICATION-TYPE + OBJECTS { + pingCtlTargetAddressType, + pingCtlTargetAddress, + pingResultsOperStatus, + pingResultsIpTargetAddressType, + pingResultsIpTargetAddress, + pingResultsMinRtt, + pingResultsMaxRtt, + pingResultsAverageRtt, + pingResultsProbeResponses, + pingResultsSentProbes, + pingResultsRttSumOfSquares, + pingResultsLastGoodProbe + + } + STATUS current + DESCRIPTION + "Generated at the completion of a ping test when the + corresponding pingCtlTrapGeneration object has the + testCompletion(2) bit set." + ::= { pingNotifications 3 } + + -- Conformance information + + -- Compliance statements + + pingCompliances OBJECT IDENTIFIER ::= { pingConformance 1 } + pingGroups OBJECT IDENTIFIER ::= { pingConformance 2 } + + -- Compliance statements + + pingFullCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for SNMP entities that + fully implement the DISMAN-PING-MIB." + MODULE -- this module + MANDATORY-GROUPS { + pingMinimumGroup, + pingCtlRowStatusGroup, + pingHistoryGroup, + pingNotificationsGroup + } + + OBJECT pingMaxConcurrentRequests + MIN-ACCESS read-only + DESCRIPTION + "The agent is not required to support set + operations to this object." + + OBJECT pingCtlStorageType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT pingCtlType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. In addition, the only + value that MUST be supported by an implementation is + pingIcmpEcho." + + OBJECT pingCtlSourceAddressType + SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } + MIN-ACCESS read-only + DESCRIPTION + "Write access to this object is not required by + implementations that are not capable of binding the + send socket with a source address. An implementation + is only required to support IPv4 and IPv6 addresses." + + OBJECT pingCtlSourceAddress + SYNTAX InetAddress (SIZE(0|4|16)) + MIN-ACCESS read-only + DESCRIPTION + "Write access to this object is not required by + implementations that are not capable of binding the + send socket with a source address. An implementation + is only required to support IPv4 and IPv6 addresses." + + OBJECT pingCtlIfIndex + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If write access is + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingCtlByPassRouteTable + MIN-ACCESS read-only + DESCRIPTION + "Write access to this object is not required by + implementations that are not capable of its + implementation. The function represented by this + object is implementable if the setsockopt + SOL_SOCKET SO_DONTROUTE option is supported." + + OBJECT pingCtlDSField + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If write access is + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingResultsIpTargetAddressType + SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } + DESCRIPTION + "An implementation is only required to + + support IPv4 and IPv6 addresses." + + OBJECT pingResultsIpTargetAddress + SYNTAX InetAddress (SIZE(0|4|16)) + DESCRIPTION + "An implementation is only required to + support IPv4 and globally unique IPv6 addresses." + + OBJECT pingResultsLastGoodProbe + DESCRIPTION + "This object is mandatory for implementations that have + access to a system clock and that are capable of setting + the values for DateAndTime objects. It is RECOMMENDED + that when this object is not supported its values + be reported as '0000000000000000'H." + + OBJECT pingProbeHistoryTime + DESCRIPTION + "This object is mandatory for implementations that have + access to a system clock and that are capable of setting + the values for DateAndTime objects. It is RECOMMENDED + that when this object is not supported its values + be reported as '0000000000000000'H." + ::= { pingCompliances 2 } + + pingMinimumCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The minimum compliance statement for SNMP entities + that implement the minimal subset of the + DISMAN-PING-MIB. Implementors might choose this + subset for small devices with limited resources." + MODULE -- this module + MANDATORY-GROUPS { pingMinimumGroup } + + GROUP pingCtlRowStatusGroup + DESCRIPTION + "A compliant implementation does not have to implement + the pingCtlRowStatusGroup." + + GROUP pingHistoryGroup + DESCRIPTION + "A compliant implementation does not have to implement + the pingHistoryGroup." + + GROUP pingNotificationsGroup + DESCRIPTION + "A compliant implementation does not have to implement + + the pingNotificationsGroup." + + OBJECT pingMaxConcurrentRequests + MIN-ACCESS read-only + DESCRIPTION + "The agent is not required to support set + operations to this object." + + OBJECT pingCtlDataFill + MIN-ACCESS read-only + DESCRIPTION + "The agent is not required to support set + operations to this object." + + OBJECT pingCtlFrequency + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If write access is + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingCtlMaxRows + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If the + pingHistoryGroup is not implemented, then write + access to this object MUST be disabled, and the object + MUST return a value of 0 when retrieved." + + OBJECT pingCtlStorageType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT pingCtlTrapGeneration + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If the + pingNotificationsGroup is not implemented, then write + access to this object MUST be disabled, and the object + MUST return a value with no bit set when retrieved. + No bit set indicates that not notification is + generated." + + OBJECT pingCtlTrapProbeFailureFilter + MIN-ACCESS read-only + DESCRIPTION + "If write access to pingCtlTrapGeneration is not + supported, then write access to this object must also + not be supported. In this case, return 0 as the value + of this object." + + OBJECT pingCtlTrapTestFailureFilter + MIN-ACCESS read-only + DESCRIPTION + "If write access to pingCtlTrapGeneration is not + supported, then write access to this object must also + not be supported. In this case, return 0 as the value + of this object." + + OBJECT pingCtlType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. In addition, the only + value that MUST be supported by an implementation is + pingIcmpEcho." + + OBJECT pingCtlDescr + MIN-ACCESS read-only + DESCRIPTION + "The agent is not required to support set + operations to this object." + + OBJECT pingCtlSourceAddressType + SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } + MIN-ACCESS read-only + DESCRIPTION + "Write access to this object is not required by + implementations that are not capable of binding the + send socket with a source address. An implementation + is only required to support IPv4 and IPv6 addresses." + + OBJECT pingCtlSourceAddress + SYNTAX InetAddress (SIZE(0|4|16)) + MIN-ACCESS read-only + DESCRIPTION + "Write access to this object is not required by + implementations that are not capable of binding the + send socket with a source address. An implementation + is only required to support IPv4 and IPv6 addresses." + + OBJECT pingCtlIfIndex + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If write access is + + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingCtlByPassRouteTable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If write access is + not supported, return false(2) as the value of this + object. A value of false(2) means that the function + represented by this option is not supported." + + OBJECT pingCtlDSField + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. If write access is + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingResultsIpTargetAddressType + SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } + DESCRIPTION + "An implementation is only required to + support IPv4 and IPv6 addresses." + + OBJECT pingResultsIpTargetAddress + SYNTAX InetAddress (SIZE(0|4|16)) + DESCRIPTION + "An implementation is only required to + support IPv4 and globally unique IPv6 addresses." + + OBJECT pingResultsLastGoodProbe + DESCRIPTION + "This object is mandatory for implementations that have + access to a system clock and that are capable of setting + the values for DateAndTime objects. It is RECOMMENDED + that when this object is not supported its values + be reported as '0000000000000000'H." + + OBJECT pingProbeHistoryTime + DESCRIPTION + "If the pingHistoryGroup is implemented, then this + object is mandatory for implementations that have + access to a system clock and that are capable of setting + the values for DateAndTime objects. It is RECOMMENDED + that when this object is not supported its values + + be reported as '0000000000000000'H." + ::= { pingCompliances 3 } + + pingCompliance MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the DISMAN-PING-MIB. This + compliance statement has been deprecated because the + group pingGroup and the pingTimeStampGroup have been + split and deprecated. The pingFullCompliance statement + is semantically identical to the deprecated + pingCompliance statement." + + MODULE -- this module + MANDATORY-GROUPS { + pingGroup, + pingNotificationsGroup + } + GROUP pingTimeStampGroup + DESCRIPTION + "This group is mandatory for implementations that have + access to a system clock and that are capable of setting + the values for DateAndTime objects. It is RECOMMENDED + that when this group is not supported the values + for the objects in this group be reported as + '0000000000000000'H." + + OBJECT pingMaxConcurrentRequests + MIN-ACCESS read-only + DESCRIPTION + "The agent is not required to support set + operations to this object." + + OBJECT pingCtlStorageType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. It is also allowed + that implementations support only the volatile + StorageType enumeration." + + OBJECT pingCtlType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. In addition, the only + value that MUST be supported by an implementation is + pingIcmpEcho." + + OBJECT pingCtlByPassRouteTable + MIN-ACCESS read-only + DESCRIPTION + "This object is not required by implementations that + are not capable of its implementation. The function + represented by this object is implementable if the + setsockopt SOL_SOCKET SO_DONTROUTE option is + supported." + + OBJECT pingCtlSourceAddressType + SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } + MIN-ACCESS read-only + DESCRIPTION + "This object is not required by implementations that + are not capable of binding the send socket with a + source address. An implementation is only required to + support IPv4 and IPv6 addresses." + + OBJECT pingCtlSourceAddress + SYNTAX InetAddress (SIZE(0|4|16)) + MIN-ACCESS read-only + DESCRIPTION + "This object is not required by implementations that + are not capable of binding the send socket with a + source address. An implementation is only required to + support IPv4 and globally unique IPv6 addresses." + + OBJECT pingCtlIfIndex + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. When write access is + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingCtlDSField + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. When write access is + not supported, return a 0 as the value of this object. + A value of 0 means that the function represented by + this option is not supported." + + OBJECT pingResultsIpTargetAddressType + SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) } + DESCRIPTION + "An implementation is only required to + support IPv4 and IPv6 addresses." + + OBJECT pingResultsIpTargetAddress + SYNTAX InetAddress (SIZE(0|4|16)) + DESCRIPTION + "An implementation is only required to + support IPv4 and globally unique IPv6 addresses." + ::= { pingCompliances 1 } + + -- MIB groupings + + pingMinimumGroup OBJECT-GROUP + OBJECTS { + pingMaxConcurrentRequests, + pingCtlTargetAddressType, + pingCtlTargetAddress, + pingCtlDataSize, + pingCtlTimeOut, + pingCtlProbeCount, + pingCtlAdminStatus, + pingCtlDataFill, + pingCtlFrequency, + pingCtlMaxRows, + pingCtlStorageType, + pingCtlTrapGeneration, + pingCtlTrapProbeFailureFilter, + pingCtlTrapTestFailureFilter, + pingCtlType, + pingCtlDescr, + pingCtlByPassRouteTable, + pingCtlSourceAddressType, + pingCtlSourceAddress, + pingCtlIfIndex, + pingCtlDSField, + pingResultsOperStatus, + pingResultsIpTargetAddressType, + pingResultsIpTargetAddress, + pingResultsMinRtt, + pingResultsMaxRtt, + pingResultsAverageRtt, + pingResultsProbeResponses, + pingResultsSentProbes, + pingResultsRttSumOfSquares, + pingResultsLastGoodProbe + } + STATUS current + DESCRIPTION + "The group of objects that constitute the remote ping + capability." + ::= { pingGroups 4 } + + pingCtlRowStatusGroup OBJECT-GROUP + OBJECTS { + pingCtlRowStatus + } + STATUS current + DESCRIPTION + "The RowStatus object of the pingCtlTable." + ::= { pingGroups 5 } + + pingHistoryGroup OBJECT-GROUP + OBJECTS { + pingProbeHistoryResponse, + pingProbeHistoryStatus, + pingProbeHistoryLastRC, + pingProbeHistoryTime + } + STATUS current + DESCRIPTION + "The group of objects that constitute the history + capability." + ::= { pingGroups 6 } + + pingNotificationsGroup NOTIFICATION-GROUP + NOTIFICATIONS { + pingProbeFailed, + pingTestFailed, + pingTestCompleted + } + STATUS current + DESCRIPTION + "The notification that are required to be supported by + implementations of this MIB." + ::= { pingGroups 3 } + + pingGroup OBJECT-GROUP + OBJECTS { + pingMaxConcurrentRequests, + pingCtlTargetAddressType, + pingCtlTargetAddress, + pingCtlDataSize, + pingCtlTimeOut, + pingCtlProbeCount, + pingCtlAdminStatus, + pingCtlDataFill, + pingCtlFrequency, + pingCtlMaxRows, + pingCtlStorageType, + pingCtlTrapGeneration, + pingCtlTrapProbeFailureFilter, + pingCtlTrapTestFailureFilter, + pingCtlType, + pingCtlDescr, + pingCtlByPassRouteTable, + pingCtlSourceAddressType, + pingCtlSourceAddress, + pingCtlIfIndex, + pingCtlDSField, + pingCtlRowStatus, + pingResultsOperStatus, + pingResultsIpTargetAddressType, + pingResultsIpTargetAddress, + pingResultsMinRtt, + pingResultsMaxRtt, + pingResultsAverageRtt, + pingResultsProbeResponses, + pingResultsSentProbes, + pingResultsRttSumOfSquares, + pingProbeHistoryResponse, + pingProbeHistoryStatus, + pingProbeHistoryLastRC + } + STATUS deprecated + DESCRIPTION + "The group of objects that constitute the remote ping + capability." + ::= { pingGroups 1 } + + pingTimeStampGroup OBJECT-GROUP + + OBJECTS { + pingResultsLastGoodProbe, + pingProbeHistoryTime + } + STATUS deprecated + DESCRIPTION + "The group of DateAndTime objects." + ::= { pingGroups 2 } + +END |