diff options
Diffstat (limited to 'mibs/TUNNEL-MIB.txt')
-rw-r--r-- | mibs/TUNNEL-MIB.txt | 738 |
1 files changed, 738 insertions, 0 deletions
diff --git a/mibs/TUNNEL-MIB.txt b/mibs/TUNNEL-MIB.txt new file mode 100644 index 000000000..5f9596b58 --- /dev/null +++ b/mibs/TUNNEL-MIB.txt @@ -0,0 +1,738 @@ +TUNNEL-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, transmission, + Integer32, IpAddress FROM SNMPv2-SMI -- [RFC2578] + + RowStatus, StorageType FROM SNMPv2-TC -- [RFC2579] + + MODULE-COMPLIANCE, + OBJECT-GROUP FROM SNMPv2-CONF -- [RFC2580] + + InetAddressType, + InetAddress FROM INET-ADDRESS-MIB -- [RFC4001] + + IPv6FlowLabelOrAny FROM IPV6-FLOW-LABEL-MIB -- [RFC3595] + + ifIndex, + InterfaceIndexOrZero FROM IF-MIB -- [RFC2863] + + IANAtunnelType FROM IANAifType-MIB; -- [IFTYPE] + +tunnelMIB MODULE-IDENTITY + LAST-UPDATED "200505160000Z" -- May 16, 2005 + ORGANIZATION "IETF IP Version 6 (IPv6) Working Group" + CONTACT-INFO + " Dave Thaler + Microsoft Corporation + One Microsoft Way + Redmond, WA 98052-6399 + EMail: dthaler@microsoft.com" + DESCRIPTION + "The MIB module for management of IP Tunnels, + independent of the specific encapsulation scheme in + use. + + Copyright (C) The Internet Society (2005). This + version of this MIB module is part of RFC 4087; see + the RFC itself for full legal notices." + + REVISION "200505160000Z" -- May 16, 2005 + DESCRIPTION + "IPv4-specific objects were deprecated, including + tunnelIfLocalAddress, tunnelIfRemoteAddress, the + tunnelConfigTable, and the tunnelMIBBasicGroup. + + Added IP version-agnostic objects that should be used + instead, including tunnelIfAddressType, + tunnelIfLocalInetAddress, tunnelIfRemoteInetAddress, + the tunnelInetConfigTable, and the + tunnelIMIBInetGroup. + + The new tunnelIfLocalInetAddress and + tunnelIfRemoteInetAddress objects are read-write, + rather than read-only. + + Updated DESCRIPTION clauses of existing version- + agnostic objects (e.g., tunnelIfTOS) that contained + IPv4-specific text to cover IPv6 as well. + + Added tunnelIfFlowLabel for tunnels over IPv6. + + The encapsulation method was previously an INTEGER + type, and is now an IANA-maintained textual + convention. + + Published as RFC 4087." + REVISION "199908241200Z" -- August 24, 1999 + DESCRIPTION + "Initial version, published as RFC 2667." + ::= { transmission 131 } + +tunnelMIBObjects OBJECT IDENTIFIER ::= { tunnelMIB 1 } + +tunnel OBJECT IDENTIFIER ::= { tunnelMIBObjects 1 } + +-- the IP Tunnel MIB-Group +-- +-- a collection of objects providing information about +-- IP Tunnels + +tunnelIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF TunnelIfEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The (conceptual) table containing information on + configured tunnels." + ::= { tunnel 1 } + +tunnelIfEntry OBJECT-TYPE + SYNTAX TunnelIfEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry (conceptual row) containing the information + on a particular configured tunnel." + INDEX { ifIndex } + ::= { tunnelIfTable 1 } + +TunnelIfEntry ::= SEQUENCE { + tunnelIfLocalAddress IpAddress, -- deprecated + tunnelIfRemoteAddress IpAddress, -- deprecated + tunnelIfEncapsMethod IANAtunnelType, + tunnelIfHopLimit Integer32, + tunnelIfSecurity INTEGER, + tunnelIfTOS Integer32, + tunnelIfFlowLabel IPv6FlowLabelOrAny, + tunnelIfAddressType InetAddressType, + tunnelIfLocalInetAddress InetAddress, + tunnelIfRemoteInetAddress InetAddress, + tunnelIfEncapsLimit Integer32 +} + +tunnelIfLocalAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The address of the local endpoint of the tunnel + (i.e., the source address used in the outer IP + header), or 0.0.0.0 if unknown or if the tunnel is + over IPv6. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelIfLocalInetAddress." + ::= { tunnelIfEntry 1 } + +tunnelIfRemoteAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The address of the remote endpoint of the tunnel + (i.e., the destination address used in the outer IP + header), or 0.0.0.0 if unknown, or an IPv6 address, or + + the tunnel is not a point-to-point link (e.g., if it + is a 6to4 tunnel). + + Since this object does not support IPv6, it is + deprecated in favor of tunnelIfRemoteInetAddress." + ::= { tunnelIfEntry 2 } + +tunnelIfEncapsMethod OBJECT-TYPE + SYNTAX IANAtunnelType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The encapsulation method used by the tunnel." + ::= { tunnelIfEntry 3 } + +tunnelIfHopLimit OBJECT-TYPE + SYNTAX Integer32 (0 | 1..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 TTL or IPv6 Hop Limit to use in the outer IP + header. A value of 0 indicates that the value is + copied from the payload's header." + ::= { tunnelIfEntry 4 } + +tunnelIfSecurity OBJECT-TYPE + SYNTAX INTEGER { + none(1), -- no security + ipsec(2), -- IPsec security + other(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The method used by the tunnel to secure the outer IP + header. The value ipsec indicates that IPsec is used + between the tunnel endpoints for authentication or + encryption or both. More specific security-related + information may be available in a MIB module for the + security protocol in use." + ::= { tunnelIfEntry 5 } + +tunnelIfTOS OBJECT-TYPE + SYNTAX Integer32 (-2..63) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The method used to set the high 6 bits (the + + differentiated services codepoint) of the IPv4 TOS or + IPv6 Traffic Class in the outer IP header. A value of + -1 indicates that the bits are copied from the + payload's header. A value of -2 indicates that a + traffic conditioner is invoked and more information + may be available in a traffic conditioner MIB module. + A value between 0 and 63 inclusive indicates that the + bit field is set to the indicated value. + + Note: instead of the name tunnelIfTOS, a better name + would have been tunnelIfDSCPMethod, but the existing + name appeared in RFC 2667 and existing objects cannot + be renamed." + ::= { tunnelIfEntry 6 } + +tunnelIfFlowLabel OBJECT-TYPE + SYNTAX IPv6FlowLabelOrAny + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The method used to set the IPv6 Flow Label value. + This object need not be present in rows where + tunnelIfAddressType indicates the tunnel is not over + IPv6. A value of -1 indicates that a traffic + conditioner is invoked and more information may be + available in a traffic conditioner MIB. Any other + value indicates that the Flow Label field is set to + the indicated value." + ::= { tunnelIfEntry 7 } + +tunnelIfAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The type of address in the corresponding + tunnelIfLocalInetAddress and tunnelIfRemoteInetAddress + objects." + ::= { tunnelIfEntry 8 } + +tunnelIfLocalInetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The address of the local endpoint of the tunnel + (i.e., the source address used in the outer IP + header). If the address is unknown, the value is + + 0.0.0.0 for IPv4 or :: for IPv6. The type of this + object is given by tunnelIfAddressType." + ::= { tunnelIfEntry 9 } + +tunnelIfRemoteInetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The address of the remote endpoint of the tunnel + (i.e., the destination address used in the outer IP + header). If the address is unknown or the tunnel is + not a point-to-point link (e.g., if it is a 6to4 + tunnel), the value is 0.0.0.0 for tunnels over IPv4 or + :: for tunnels over IPv6. The type of this object is + given by tunnelIfAddressType." + ::= { tunnelIfEntry 10 } + +tunnelIfEncapsLimit OBJECT-TYPE + SYNTAX Integer32 (-1 | 0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum number of additional encapsulations + permitted for packets undergoing encapsulation at this + node. A value of -1 indicates that no limit is + present (except as a result of the packet size)." + REFERENCE "RFC 2473, section 4.1.1" + ::= { tunnelIfEntry 11 } + +tunnelConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF TunnelConfigEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "The (conceptual) table containing information on + configured tunnels. This table can be used to map a + set of tunnel endpoints to the associated ifIndex + value. It can also be used for row creation. Note + that every row in the tunnelIfTable with a fixed IPv4 + destination address should have a corresponding row in + the tunnelConfigTable, regardless of whether it was + created via SNMP. + + Since this table does not support IPv6, it is + deprecated in favor of tunnelInetConfigTable." + ::= { tunnel 2 } + +tunnelConfigEntry OBJECT-TYPE + SYNTAX TunnelConfigEntry + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry (conceptual row) containing the information + on a particular configured tunnel. + + Since this entry does not support IPv6, it is + deprecated in favor of tunnelInetConfigEntry." + INDEX { tunnelConfigLocalAddress, + tunnelConfigRemoteAddress, + tunnelConfigEncapsMethod, + tunnelConfigID } + ::= { tunnelConfigTable 1 } + +TunnelConfigEntry ::= SEQUENCE { + tunnelConfigLocalAddress IpAddress, + tunnelConfigRemoteAddress IpAddress, + tunnelConfigEncapsMethod IANAtunnelType, + tunnelConfigID Integer32, + tunnelConfigIfIndex InterfaceIndexOrZero, + tunnelConfigStatus RowStatus +} + +tunnelConfigLocalAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "The address of the local endpoint of the tunnel, or + 0.0.0.0 if the device is free to choose any of its + addresses at tunnel establishment time. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelInetConfigLocalAddress." + ::= { tunnelConfigEntry 1 } + +tunnelConfigRemoteAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "The address of the remote endpoint of the tunnel. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelInetConfigRemoteAddress." + ::= { tunnelConfigEntry 2 } + +tunnelConfigEncapsMethod OBJECT-TYPE + SYNTAX IANAtunnelType + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "The encapsulation method used by the tunnel. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelInetConfigEncapsMethod." + ::= { tunnelConfigEntry 3 } + +tunnelConfigID OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An identifier used to distinguish between multiple + tunnels of the same encapsulation method, with the + same endpoints. If the encapsulation protocol only + allows one tunnel per set of endpoint addresses (such + as for GRE or IP-in-IP), the value of this object is + 1. For encapsulation methods (such as L2F) which + allow multiple parallel tunnels, the manager is + responsible for choosing any ID which does not + conflict with an existing row, such as choosing a + random number. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelInetConfigID." + ::= { tunnelConfigEntry 4 } + +tunnelConfigIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "If the value of tunnelConfigStatus for this row is + active, then this object contains the value of ifIndex + corresponding to the tunnel interface. A value of 0 + is not legal in the active state, and means that the + interface index has not yet been assigned. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelInetConfigIfIndex." + ::= { tunnelConfigEntry 5 } + +tunnelConfigStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS deprecated + DESCRIPTION + "The status of this row, by which new entries may be + created, or old entries deleted from this table. The + agent need not support setting this object to + createAndWait or notInService since there are no other + writable objects in this table, and writable objects + in rows of corresponding tables such as the + tunnelIfTable may be modified while this row is + active. + + To create a row in this table for an encapsulation + method which does not support multiple parallel + tunnels with the same endpoints, the management + station should simply use a tunnelConfigID of 1, and + set tunnelConfigStatus to createAndGo. For + encapsulation methods such as L2F which allow multiple + parallel tunnels, the management station may select a + pseudo-random number to use as the tunnelConfigID and + set tunnelConfigStatus to createAndGo. In the event + that this ID is already in use and an + inconsistentValue is returned in response to the set + operation, the management station should simply select + a new pseudo-random number and retry the operation. + + Creating a row in this table will cause an interface + index to be assigned by the agent in an + implementation-dependent manner, and corresponding + rows will be instantiated in the ifTable and the + tunnelIfTable. The status of this row will become + active as soon as the agent assigns the interface + index, regardless of whether the interface is + operationally up. + + Deleting a row in this table will likewise delete the + corresponding row in the ifTable and in the + tunnelIfTable. + + Since this object does not support IPv6, it is + deprecated in favor of tunnelInetConfigStatus." + ::= { tunnelConfigEntry 6 } + +tunnelInetConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF TunnelInetConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The (conceptual) table containing information on + configured tunnels. This table can be used to map a + set of tunnel endpoints to the associated ifIndex + value. It can also be used for row creation. Note + that every row in the tunnelIfTable with a fixed + destination address should have a corresponding row in + the tunnelInetConfigTable, regardless of whether it + was created via SNMP." + ::= { tunnel 3 } + +tunnelInetConfigEntry OBJECT-TYPE + SYNTAX TunnelInetConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry (conceptual row) containing the information + on a particular configured tunnel. Note that there is + a 128 subid maximum for object OIDs. Implementers + need to be aware that if the total number of octets in + tunnelInetConfigLocalAddress and + tunnelInetConfigRemoteAddress exceeds 110 then OIDs of + column instances in this table will have more than 128 + sub-identifiers and cannot be accessed using SNMPv1, + SNMPv2c, or SNMPv3. In practice this is not expected + to be a problem since IPv4 and IPv6 addresses will not + cause the limit to be reached, but if other types are + supported by an agent, care must be taken to ensure + that the sum of the lengths do not cause the limit to + be exceeded." + INDEX { tunnelInetConfigAddressType, + tunnelInetConfigLocalAddress, + tunnelInetConfigRemoteAddress, + tunnelInetConfigEncapsMethod, + tunnelInetConfigID } + ::= { tunnelInetConfigTable 1 } + +TunnelInetConfigEntry ::= SEQUENCE { + tunnelInetConfigAddressType InetAddressType, + tunnelInetConfigLocalAddress InetAddress, + tunnelInetConfigRemoteAddress InetAddress, + tunnelInetConfigEncapsMethod IANAtunnelType, + tunnelInetConfigID Integer32, + tunnelInetConfigIfIndex InterfaceIndexOrZero, + tunnelInetConfigStatus RowStatus, + tunnelInetConfigStorageType StorageType +} + +tunnelInetConfigAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The address type over which the tunnel encapsulates + packets." + ::= { tunnelInetConfigEntry 1 } + +tunnelInetConfigLocalAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The address of the local endpoint of the tunnel, or + 0.0.0.0 (for IPv4) or :: (for IPv6) if the device is + free to choose any of its addresses at tunnel + establishment time." + ::= { tunnelInetConfigEntry 2 } + +tunnelInetConfigRemoteAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The address of the remote endpoint of the tunnel." + ::= { tunnelInetConfigEntry 3 } + +tunnelInetConfigEncapsMethod OBJECT-TYPE + SYNTAX IANAtunnelType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The encapsulation method used by the tunnel." + ::= { tunnelInetConfigEntry 4 } + +tunnelInetConfigID OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An identifier used to distinguish between multiple + tunnels of the same encapsulation method, with the + same endpoints. If the encapsulation protocol only + allows one tunnel per set of endpoint addresses (such + as for GRE or IP-in-IP), the value of this object is + 1. For encapsulation methods (such as L2F) which + allow multiple parallel tunnels, the manager is + responsible for choosing any ID which does not + + conflict with an existing row, such as choosing a + random number." + ::= { tunnelInetConfigEntry 5 } + +tunnelInetConfigIfIndex OBJECT-TYPE + SYNTAX InterfaceIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If the value of tunnelInetConfigStatus for this row + is active, then this object contains the value of + ifIndex corresponding to the tunnel interface. A + value of 0 is not legal in the active state, and means + that the interface index has not yet been assigned." + ::= { tunnelInetConfigEntry 6 } + +tunnelInetConfigStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row, by which new entries may be + created, or old entries deleted from this table. The + agent need not support setting this object to + createAndWait or notInService since there are no other + writable objects in this table, and writable objects + in rows of corresponding tables such as the + tunnelIfTable may be modified while this row is + active. + + To create a row in this table for an encapsulation + method which does not support multiple parallel + tunnels with the same endpoints, the management + station should simply use a tunnelInetConfigID of 1, + and set tunnelInetConfigStatus to createAndGo. For + encapsulation methods such as L2F which allow multiple + parallel tunnels, the management station may select a + pseudo-random number to use as the tunnelInetConfigID + and set tunnelInetConfigStatus to createAndGo. In the + event that this ID is already in use and an + inconsistentValue is returned in response to the set + operation, the management station should simply select + a new pseudo-random number and retry the operation. + + Creating a row in this table will cause an interface + index to be assigned by the agent in an + implementation-dependent manner, and corresponding + rows will be instantiated in the ifTable and the + + tunnelIfTable. The status of this row will become + active as soon as the agent assigns the interface + index, regardless of whether the interface is + operationally up. + + Deleting a row in this table will likewise delete the + corresponding row in the ifTable and in the + tunnelIfTable." + ::= { tunnelInetConfigEntry 7 } + +tunnelInetConfigStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The storage type of this row. If the row is + permanent(4), no objects in the row need be writable." + ::= { tunnelInetConfigEntry 8 } + +-- conformance information + +tunnelMIBConformance + OBJECT IDENTIFIER ::= { tunnelMIB 2 } +tunnelMIBCompliances + OBJECT IDENTIFIER ::= { tunnelMIBConformance 1 } +tunnelMIBGroups OBJECT IDENTIFIER ::= { tunnelMIBConformance 2 } + +-- compliance statements + +tunnelMIBCompliance MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The (deprecated) IPv4-only compliance statement for + the IP Tunnel MIB. + + This is deprecated in favor of + tunnelMIBInetFullCompliance and + tunnelMIBInetReadOnlyCompliance." + MODULE -- this module + MANDATORY-GROUPS { tunnelMIBBasicGroup } + + OBJECT tunnelIfHopLimit + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelIfTOS + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelConfigStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { tunnelMIBCompliances 1 } + +tunnelMIBInetFullCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The full compliance statement for the IP Tunnel MIB." + MODULE -- this module + MANDATORY-GROUPS { tunnelMIBInetGroup } + + OBJECT tunnelIfAddressType + SYNTAX InetAddressType { ipv4(1), ipv6(2), + ipv4z(3), ipv6z(4) } + DESCRIPTION + "An implementation is only required to support IPv4 + and/or IPv6 addresses. An implementation only needs to + support the addresses it actually supports on the + device." + ::= { tunnelMIBCompliances 2 } + +tunnelMIBInetReadOnlyCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The read-only compliance statement for the IP Tunnel + MIB." + MODULE -- this module + MANDATORY-GROUPS { tunnelMIBInetGroup } + + OBJECT tunnelIfHopLimit + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelIfTOS + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelIfFlowLabel + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelIfAddressType + SYNTAX InetAddressType { ipv4(1), ipv6(2), + ipv4z(3), ipv6z(4) } + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required. + + An implementation is only required to support IPv4 + and/or IPv6 addresses. An implementation only needs to + support the addresses it actually supports on the + device." + + OBJECT tunnelIfLocalInetAddress + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelIfRemoteInetAddress + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelIfEncapsLimit + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT tunnelInetConfigStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required, and active is the only + status that needs to be supported." + + OBJECT tunnelInetConfigStorageType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { tunnelMIBCompliances 3 } + +-- units of conformance + +tunnelMIBBasicGroup OBJECT-GROUP + OBJECTS { tunnelIfLocalAddress, tunnelIfRemoteAddress, + tunnelIfEncapsMethod, tunnelIfHopLimit, tunnelIfTOS, + tunnelIfSecurity, tunnelConfigIfIndex, tunnelConfigStatus } + STATUS deprecated + DESCRIPTION + "A collection of objects to support basic management + + of IPv4 Tunnels. Since this group cannot support + IPv6, it is deprecated in favor of + tunnelMIBInetGroup." + ::= { tunnelMIBGroups 1 } + +tunnelMIBInetGroup OBJECT-GROUP + OBJECTS { tunnelIfAddressType, tunnelIfLocalInetAddress, + tunnelIfRemoteInetAddress, tunnelIfEncapsMethod, + tunnelIfEncapsLimit, + tunnelIfHopLimit, tunnelIfTOS, tunnelIfFlowLabel, + tunnelIfSecurity, tunnelInetConfigIfIndex, + tunnelInetConfigStatus, tunnelInetConfigStorageType } + STATUS current + DESCRIPTION + "A collection of objects to support basic management + of IPv4 and IPv6 Tunnels." + ::= { tunnelMIBGroups 2 } + +END |