Age | Commit message (Collapse) | Author |
|
maxsyslogins
maximum number of all logins on system; user is not
allowed to log-in if total number of all user logins is
greater than specified number (this limit does not apply
to user with uid=0)
set system login max-login-session 2
|
|
We now support assigning discrete IPv6 addresses to a container.
|
|
|
|
T5128: Policy Route: allow wildcard on interface
|
|
Add op-mode for sFlow based on hsflowd "show sflow"
Add machine readable format '--raw' and formatted output
|
|
|
|
|
|
dns: T5115: Support custom port for name servers for forwarding zones
|
|
As podman is going to use netavark as new default we must explicitly select
the old driver until we have migrated to netavark.
|
|
This would allow using custom ports in name server operating on non-
default port for forwarding zones.
This is a follow-up to T5113 for sake of completeness and having
consistent treatment of all name servers configured in PowerDNS recursor.
Additionally, migrate `service dns forwarding domain example.com server`
to `service dns forwarding domain foo3.com name-server` for consistency
and reusability.
|
|
|
|
|
|
This is basic configuration to enable NTS support in chrony.
|
|
T5099: IPoE-server add option next-pool for named ip pools
|
|
ipsec: T5043: Rewritten and fixed 'reset vpn' commands
|
|
In cases with multiple named IP pools, it is required the option 'next'
to be sure that if IP addresses ended in one pool, then they would
begin to be allocated from the next named pool.
For accel-ppp it requires specific order as pool must be defined
before we can use it with the 'next-option'
set service ipoe-server client-ip-pool name first-pool subnet '192.0.2.0/25'
set service ipoe-server client-ip-pool name first-pool next-pool 'second-pool'
set service ipoe-server client-ip-pool name second-pool subnet '203.0.113.0/25'
[ip-pool]
203.0.113.0/25,name=second-pool
192.0.2.0/25,name=first-pool,next=second-pool
|
|
|
|
hsflowd will export the headers of dropped packets (along with the
name of the function in the Linux kernel where that skb was dropped)
as part of the standard sFlow feed.
This measurement complements the sFlow packet sampling and
counter-telemetry well because it provides visibility into the
traffic that is not flowing.
Very helpful for troubleshooting.
The limit (a rate limit max of N drops per second sent out in the
sFlow datagrams) is the parameter you would set in the CLI.
set system sflow drop-monitor-limit 50
|
|
T5092: IPoE-server named pool must not rely on auth type
|
|
1. Rewritten CLI of 'reset vpn' commands.
2. Created 'reset vpn ipsec remote-access' commands to reset
RA IKEv2 session.
3. Created 'reset vpn ipsec site-to-site all' command to reset all
configured IPSec site-to-site peers sessions.
4. Rewritten 'reset vpn l2t|pptp|sstp' commands to
new opmode style.
|
|
Named pools for ipoe-server must not rely on autentication type
It is a separate global option for [ipoe] and [ip-pool] sections
|
|
Add sFlow feature based on hsflowd
According to user reviews, it works more stable and more productive
than pmacct
I haven't deleted 'pmacct' 'system flow-accounting sflow' yet
It could be migrated or deprecated later
set system sflow agent-address '192.0.2.14'
set system sflow interface 'eth0'
set system sflow interface 'eth1'
set system sflow polling '30'
set system sflow sampling-rate '100'
set system sflow server 192.0.2.1 port '6343'
set system sflow server 192.0.2.11 port '6343'
|
|
Add template to generate zebra
"ipv6 protocol ospf6 route-map xxx"
|
|
Fix podman error about invalid storage:
[graphdriver] prior storage driver overlay failed: 'overlay' is not supported
over overlayfs, a mount_program is required: backing file system is unsupported
for this graph driver" Error: 'overlay' is not supported over overlayfs, a
mount_program is required: backing file system is unsupported for this graph
driver.
|
|
Container registry CLI node changed from leafNode to tagNode with the same
defaults. In addition we can now configure an authentication option per
registry.
|
|
qos: T5018: Fix issues between QoS and interface mirror/redirect
|
|
This will check if mirror/redirect is present on a QoS interface and use `vyos.configdep` module to update the interface again after QoS is applied.
|
|
If the 'client-subnet' is not used we must exclude it
from the ipoe.config.j2 template.
Otherwise we get wrong empty parameter ',range=,'
|
|
Fix incorrect regex '\d+' when used vlan ranges
For example 'ipoe-server interface eth1 vlan 2000-3000'
- replace 'interface=re:eth1\.\d+'
=> 'interface=re:^eth1\.(200\d|20[1-9]\d|2[1-9]\d{2}|3000)$'
|
|
After rewriting IPoE server for config.dict the ipoe.config.j2
template wasn't changed for 'vlan-mon' section
Fix it
|
|
T4977: Add Babel routing protocol support
|
|
login: T4943: Fixed 2FA + RADIUS compatibility
|
|
MFA requires KbdInteractiveAuthentication to ask a second factor, and the RADIUS
module for PAM does not like it, which makes them incompatible.
This commit:
* disables KbdInteractiveAuthentication
* changes order for PAM modules - make it first, before `pam_unix` or
`pam_radius_auth`
* enables the `forward_pass` option for `pam_google_authenticator` to accept
both password and MFA in a single input
As a result, local, RADIUS, and MFA work together.
Important change: MFA should be entered together with a password.
Before:
```
vyos login: <USERNAME>
Password: <PASSWORD>
Verification code: <MFA>
```
Now:
```
vyos login: <USERNAME>
Password & verification code: <PASSWORD><MFA>
```
|
|
T5029: Change nginx default root directory
|
|
|
|
|
|
* We will need to remove insecure ciphers as a long-term solution (BF-CBC, DES...)
|
|
Disabling authentication is useful in emergency situations
(e.g. RADIUS server is down) or testing purposes.
Clients can connect with any login and username.
set service pppoe-server authentication mode 'noauth'
|
|
debian: T5003: Upgrade base system to Debian 12 "Bookworm"
|
|
Not supported with swanctl
|
|
Fixes "chronyd: Fatal error : Not superuser"
Fixes "ip[6394]: Failed to open mounts file: No such file or directory" when in VRF
|
|
|
|
Replace links to the phabricator site from https://phabricator.vyos.net to
https://vyos.dev
|
|
T4857: snmp: Fix error when not defining client|network under community
|
|
After the RESTRICTED view was introduced snmpd requires a network to be
specified. Before adding the RESTRICTED view snmpd always assumed the default
network 0.0.0.0/0.
This commit re-adds the build in default networks for IPv4 and IPv6 and
exposes it as a proper default to the CLI so the user is informed about it:
vyos@vyos# set service snmp community foooo
Possible completions:
authorization Authorization type (default: ro)
+ client IP address of SNMP client allowed to contact system
+ network Subnet of SNMP client(s) allowed to contact system (default:
0.0.0.0/0, ::/0)
|
|
sstp-client
|
|
T1993: PPPoE-server add section shaper and fwmark option
|
|
nhrp: T4905: Rewritten nhrp op-mode in new style
|
|
containers"
This reverts commit b17251334c57c2f6875c19ad4e6c6127aa9e1811.
|
|
container: T4959: Add container registry authentication config for containers
|