summaryrefslogtreecommitdiff
path: root/src/conf_mode/service_pppoe-server.py
AgeCommit message (Collapse)Author
2024-05-01Merge pull request #3364 from natali-rs1985/T6234-currentDaniil Baturin
pppoe-server: T6234: PPPoE-server pado-delay refactoring
2024-04-29T6272: Changed interface existence verification in pppoe/ipoe to Warningaapostoliuk
Throwing Warning message instead of Error if interface which is used in pppoe/ipoe does not exist.
2024-04-25pppoe-server: T6234: PPPoE-server pado-delay refactoringNataliia Solomko
2024-04-12pppoe-server: T6141: T5364: PPPoE-server add pado-delay without sessions ↵Nataliia Solomko
fails (#3296)
2024-02-15T6029: Rewritten Accel-PPP services to an identical feature setaapostoliuk
Removed dhcp-interface option (l2tp) Added wins-server (sstp) Added description (ipoe, pppoe, sstp, pptp) Added exteded-script (l2tp, sstp, pptp) Added shaper (ipoe, pptp, sstp, l2tp) Added limits (ipoe, pptp, sstp, l2tp) Added snmp ( ipoe, pptp,sstp, l2tp) Refactoring and reformated code.
2024-02-07T5960: Rewritten authentication node in PPTP to a single viewaapostoliuk
Rewritten authentication node in accel-ppp services to a single view. In particular - PPTP authentication.
2024-01-16T5865: Moved ipv6 pools to named ipv6 pools in accel-pppaapostoliuk
Moved ipv6 pools to named ipv6 pools in accel-ppp services
2023-12-04accel-ppp: T5688: Standardized pool configuration in accel-pppaapostoliuk
Standardized pool configuration for all accel-ppp services. 1. Only named pools are used now. 2. Allows all services to use range in x.x.x.x/mask and x.x.x.x-x.x.x.y format 3. next-pool can be used in all services 2. Allows to use in ipoe gw-ip-address without pool configuration which allows to use Fraimed-IP-Address attribute by radius. 3. Default pool name should be explicidly configured with default-pool. 4. In ipoe netmask and range subnet can be different.
2023-11-07T5720: Fix for PPPoE-server adding new interfacesViacheslav Hletenko
If we add a new interface for PPPoe-server we MUST restart the `accel-ppp@pppoe.service` as `reload` is not implemented for accel-ppp daemon Otherwise we have listen interface in the /run/accel-pppd/pppoe.conf which does not work
2023-07-14T5195: vyos.util -> vyos.utils package refactoring (#2093)Christian Breunig
* T5195: move run, cmd, call, rc_cmd helper to vyos.utils.process * T5195: use read_file and write_file implementation from vyos.utils.file Changed code automatically using: find . -type f -not -path '*/\.*' -exec sed -i 's/^from vyos.util import read_file$/from vyos.utils.file import read_file/g' {} + find . -type f -not -path '*/\.*' -exec sed -i 's/^from vyos.util import write_file$/from vyos.utils.file import write_file/g' {} + * T5195: move chmod* helpers to vyos.utils.permission * T5195: use colon_separated_to_dict from vyos.utils.dict * T5195: move is_systemd_service_* to vyos.utils.process * T5195: fix boot issues with missing imports * T5195: move dict_search_* helpers to vyos.utils.dict * T5195: move network helpers to vyos.utils.network * T5195: move commit_* helpers to vyos.utils.commit * T5195: move user I/O helpers to vyos.utils.io
2023-05-09T5214: Fix warning if a named pool is defined for PPPoE-serverViacheslav Hletenko
2022-12-02T4805: Restart pppoe-server if client pool was changedViacheslav Hletenko
Some changes for 'service pppoe-server' require 'restart' the accel-ppp@pppoe.service But we use option 'reload-or-restart' that doesn't work correctly with 'accel-ppp' Restart pppoe-server if client pool was changed
2022-09-21ipoe: T4678: T4703: rewrite to get_config_dict()Christian Poessinger
In addition to the rewrite to make use of get_config_dict() the CLI is slightly adjusted as specified in T4703. * Rename vlan-id and vlan-range to simply vlan * Rename network-mode to simply mode * Re-use existing common Jinja2 template for Accel-PPP which are shared with PPPoE and SSTP server. * Retrieve default values via defaultValue XML node
2022-09-17pppoe-server: T4703: combine vlan-id and vlan-range into single CLI nodeChristian Poessinger
The initial Accel-PPP PPPoE implementation used: set service pppoe-server interface <name> vlan-id <id> set service pppoe-server interface <name> vlan-range <start-stop> This is actually a duplicated CLI node.
2022-05-01accel-ppp: T4353: fix Jinja2 linting errorsChristian Poessinger
2021-12-07pppoe-server: T3006: Add range to regex generatorDmitriyEshenko
2020-11-27vyos.template: T2720: always enable Jinja2 trim_blocks featureChristian Poessinger
2020-10-28vyos.util: T2995: rename vyos_dict_search() -> dict_search()Christian Poessinger
Renamed using snippet below: ---------------------------- for file in $(find . -name "*.py") do sed -i "s/vyos_dict_search/dict_search/" $file done
2020-10-04sstp: T2960: migrate to get_config_dict() and reusable templatesChristian Poessinger
2020-10-04pppoe-server: T2953: prepare common chap-secrets fileChristian Poessinger
2020-10-04pppoe-server: T2953: rename CLI local-ip to gateway-addressChristian Poessinger
Required to get a common CLI for all services provided by Accel-PPP. Once the CLI for each service is consitent - Jinja2 templates can be reused together with get_config_dict().
2020-10-03pppoe-server: T2936: three IPv6 name-servers are supportedChristian Poessinger
2020-10-03pppoe-server: T2936: move v4/v6 nameserver lists out of for loopChristian Poessinger
2020-10-03pppoe-server: T2956: make use of defaultValue list featureChristian Poessinger
2020-10-03accel-ppp: T2953: fix missing defaultValue on mppeChristian Poessinger
Commit ba050937 ("accel-ppp: T2953: drop redundant CLI definitions ") dropped the defaultValue of 'prefer' for MPPE making the smoketests fail. This has been corrected.
2020-10-01pppoe-server: T2936: move to get_config_dict()Christian Poessinger
For easier configuration read in (CLI) validation and also template rendering it makes sense to drop the old, single implementation and move to the new, generic get_config_dict() approach. Recurring configuration parts like ip-pool, ipv6-pool and nameservers have also been split our into individual templates which will be included through Jinja2 - leading to a single-source of the template sections, too.
2020-09-28pppoe-server: T2919: Add possibility change Called-Station-Id formatDmitriyEshenko
2020-09-26accel-ppp: T2918: Add accounting interim jitter optionsever-sever
2020-09-26accel-ppp: T2917: Add Preallocate NAS-port-idsever-sever
2020-08-31configd: T2582: add scripts to include list for daemonJohn Estabrook
2020-08-15pppoe-server: T2796: at least one server interface must be definedChristian Poessinger
Add missing verify() check that at least one interface must be defined to listen to PPPoE data.
2020-08-02accel-ppp: T2756: make RADIUS accounting port configurableChristian Poessinger
Make the port used for RADIUS accounting user configurable. This is now valid for the following services which are based on Accel-PPP: * ipoe-server * pppoe-server * l2tp * pptp * sstp
2020-06-22pppoe-server: T2314: fix improper use of fail-time dictionary keyChristian Poessinger
2020-05-29airbag: T2088: explicit enabling of the featureThomas Mangin
airbag must now be explicitly installed. the patch also allow to fully disables the installation of the logging code at setup (and not just installing and doing nothing)
2020-04-27Merge pull request #382 from DmitriyEshenko/fix-pppoe-sesctrlChristian Poessinger
pppoe-server: T2391: Migrate single-session param to [common] section
2020-04-27pppoe-server: T2391: Migrate single-session param to [common] sectionDmitriyEshenko
2020-04-27template: T2388: move mkdir/chmod/chown within render()Thomas Mangin
2020-04-23pppoe-server: T2373: Implement CLI commands for auth protocolsDmitriyEshenko
2020-04-22accel-ppp: fix wrong reference in verify() on missing attributesChristian Poessinger
2020-04-21vyos.util: migrate all cpu_count() occurances to common get_half_cpus()Christian Poessinger
2020-04-21pppoe-server: T2314: pass proper content variable to render()Christian Poessinger
2020-04-19pppoe-server: T2314: add common accel-radius-additions XML fileChristian Poessinger
2020-04-18ipoe-server: T2324: remove boilerplate code and adjust to other accel ↵Christian Poessinger
implementations
2020-04-18accel-ppp: T2314: use common tempplate for chap-secretsChristian Poessinger
2020-04-18pppoe-server: T2314: migrate IPv6 to common CLI nodes with embeeded validationChristian Poessinger
2020-04-18pppoe-server: T2314: migrate RADIUS configuration to common CLI syntaxChristian Poessinger
2020-04-18pppoe-server: T2314: migrate IPv4/IPv6 name-servers to common nodeChristian Poessinger
Instead of having "dns-server server-1|server-2" nodes and the same for IPv6 all DNS nameservers are migrated to a common name-servers node.
2020-04-18pppoe-server: T2314: remove boilerplate code and adjustChristian Poessinger