summaryrefslogtreecommitdiff
path: root/src
AgeCommit message (Collapse)Author
2023-11-20Merge pull request #2508 from c-po/t5762-https-api-socketDaniil Baturin
http: T5762: api: make API socket backend communication the one and only default
2023-11-20T5763: fix imprecise check for remote file nameJohn Estabrook
2023-11-20http: T5762: api: make API socket backend communication the one and only defaultChristian Breunig
Why: Smoketests fail as they can not establish IPv6 connection to uvicorn backend server. https://github.com/vyos/vyos-1x/pull/2481 added a bunch of new smoketests. While debugging those failing, it was uncovered, that uvicorn only listens on IPv4 connections vyos@vyos# netstat -tulnp | grep 8080 (Not all processes could be identified, non-owned process info will not be shown, you would have to be root to see it all.) tcp 0 0 127.0.0.1:8080 0.0.0.0:* LISTEN - As the CLI already has an option to move the API communication from an IP to a UNIX domain socket, the best idea is to make this the default way of communication, as we never directly talk to the API server but rather use the NGINX reverse proxy.
2023-11-18Merge pull request #2500 from sever-sever/T5749Christian Breunig
T5749: Swap show interfaces and show interfaces summary
2023-11-17T5749: Swap show interfaces and show interfaces summaryViacheslav Hletenko
By default show VRF, MAC, MTU for `show interfaces` The original `show interfaces` moved to `show interfacces summary`
2023-11-16Merge pull request #1768 from zdc/T4516-sagittaJohn Estabrook
image: T4516: Added system image tools
2023-11-16image: T4516: add raid-1 install supportJohn Estabrook
2023-11-16image: T4516: ensure compatibility with legacy RAID 1 installsJohn Estabrook
2023-11-16image: T4516: variable name spellingJohn Estabrook
2023-11-16image: T4516: restore select entry to set/delete imageJohn Estabrook
2023-11-16image: T4516: do not prompt for confirmation when setting defaultJohn Estabrook
2023-11-16image: T4516: reword some messages and promptsJohn Estabrook
2023-11-16image: T4516: add clearer error msg on attempt to upgrade to 1.2.xJohn Estabrook
An attempt to upgrade to 1.2.x is caught, but error is of failed checksum verification; add check and message.
2023-11-16image: T4516: use copy of pw_reset script for install, link for compatJohn Estabrook
Note that this was updated for the fix in T5739.
2023-11-16T3983: show pki certificate Doesnt show x509 certificatesJeffWDH
2023-11-16T5747: op-mode add MAC and MTU for show interfaces summaryViacheslav Hletenko
Add op-mode "show interfaces summary" Add MAC, VRF and MTU options: vyos@r4# run show interfaces summary Codes: S - State, L - Link, u - Up, D - Down, A - Admin Down Interface IP Address MAC VRF MTU S/L Description ----------- ----------------- ----------------- ------- ----- ----- ------------- dum0 203.0.113.1/32 96:44:ad:c5:a1:a5 default 1500 u/u eth0 192.168.122.14/24 52:54:00:f1:fd:77 default 1500 u/u WAN eth1 192.0.2.1/24 52:54:00:04:33:2b foo 1500 u/u LAN-eth1 eth2 - 52:54:00:40:2e:af default 1504 u/u LAN-eth2 eth3 - 52:54:00:09:a4:b4 default 1500 A/D
2023-11-15image: T4516: support for interoperability of legacy/new image toolsJohn Estabrook
This commit allows management of system images with either new or legacy tools: 'add/delete/rename system image' and 'set default' are translated appropriately on booting between images with the old and new tools. Consequently, the warning of the initial commit of T4516 is dropped.
2023-11-15image: T4516: improve format of 'show system image details'John Estabrook
2023-11-15image: T5195: vyos.util -> vyos.utils package refactoringJohn Estabrook
2023-11-15image: T4516: restore reboot reminder messageJohn Estabrook
2023-11-15image: T4516: set op-mode files executableJohn Estabrook
2023-11-15image: T4516: do not prompt for config copy on live installJohn Estabrook
2023-11-15image: T4516: service vyos-grub-update should exit on live bootJohn Estabrook
2023-11-15image: T4516: correct implementation of configure_authenticationJohn Estabrook
2023-11-15image: T4516: correct permissions on creation of config directoryJohn Estabrook
2023-11-15image: T4516: Added system image toolszsdc
This commit adds the whole set of system image tools written from the scratch in Python that allows performing all the operations on images: * check information * perform installation and deletion * versions management Also, it contains a new service that will update the GRUB menu and keep tracking its version in the future. WARNING: The commit contains non-reversible changes. Because of boot menu changes, it will not be possible to manage images from older VyOS versions after an update.
2023-11-15Merge pull request #2476 from c-po/frr-pim-T5733Christian Breunig
pim(6): T5733: add missing FRR related features
2023-11-15pim: T5733: incorporate feedback from peer reviewChristian Breunig
2023-11-15T5732: generate firewall rule-resequence drops geoip country-code from outputJeffWDH
2023-11-14T5729: firewall and policy: fix latest migration scriptNicolas Fort
2023-11-13pim6: T5733: add missing FRR PIM6 related featuresChristian Breunig
2023-11-13pim: T5733: fix CLI level of global PIM commandsChristian Breunig
2023-11-13igmp: T5736: migrate "protocols igmp" to "protocols pim"Christian Breunig
IGMP and PIM are two different but related things. FRR has both combined in pimd. As we use get_config_dict() and FRR reload it is better to have both centrally stored under the same CLI node (as FRR does, too) to just "fire and forget" the commit to the daemon. "set protocols igmp interface eth1" -> "set protocols pim interface eth1 igmp"
2023-11-13pim: T5733: add missing FRR PIM related featuresChristian Breunig
Migrate CLI configuration retrival to common get_config_dict(). In addition add new functionality to VyOS that is PIM related and already available in FRR.
2023-11-12ospf: T5467: remove superfluous "import os"Christian Breunig
2023-11-12Merge pull request #2435 from bbabich/currentChristian Breunig
mtr: T5658: Add VRF support for mtr (+ op_mode wrapper)
2023-11-12op-mode: T5658: fix "monitor traceroute" completion helperChristian Breunig
2023-11-12op-mode: T5658: reduce amount of exposed optionsChristian Breunig
Example: we should focus on JSON output and not expose XML and CSV.
2023-11-12T5658: add common methods interface_list() and vrf_list() to vyos.utils.networkChristian Breunig
Reduce amount of duplicated (3 times) code in op-mode scripts for ping, traceroute and mtr.
2023-11-11Merge pull request #2471 from nicolas-fort/T5729Christian Breunig
T5729: firewall: switch to valueless in
2023-11-11dhclient: T5724: run user hooks using run_hookdirgavol
User hooks are executed using run_hookdir (defined in the /sbin/dhclient-script script) instead of run-parts. That allows user hooks to modify variables set by the dhcp client (e.g., the new_routers variable to avoid the installation of the default routes).
2023-11-10T5729: firewall: switch to valueless in order to remove unnecessary ↵Nicolas Fort
<enable|disable> commands; log and state moved to new syntax.
2023-11-10ddclient: T5708: Additional smoketests for web-optionsIndrajit Raychaudhuri
Add additional smoketests for web-options validation. Also, format error messages to optionally include protocol name.
2023-11-09op-mode: T5658: add VRF support for "monitor traceroute"bbabich
2023-11-08Merge pull request #2459 from indrajitr/mdns-streamlineViacheslav Hletenko
mdns: T5723: Always reload systemd daemon before applying changes
2023-11-07mdns: T5723: Always reload systemd daemon before applying changesIndrajit Raychaudhuri
Additionally, templatize system service override and move it to the runtime path.
2023-11-07Merge pull request #2240 from sever-sever/T5559Christian Breunig
T5559: Add static neighbor-proxy feature
2023-11-07Merge pull request #2436 from sever-sever/T5706Daniil Baturin
T5706: Add custom systemd udev rules to exclude dynamic interfaces
2023-11-07Merge pull request #2437 from sempervictus/bug/strip_secrets_misses_secretDaniil Baturin
T5713: Strip string after "secret" in IPSEC configs
2023-11-07T5720: Fix for PPPoE-server adding new interfacesViacheslav Hletenko
If we add a new interface for PPPoe-server we MUST restart the `accel-ppp@pppoe.service` as `reload` is not implemented for accel-ppp daemon Otherwise we have listen interface in the /run/accel-pppd/pppoe.conf which does not work