Age | Commit message (Collapse) | Author |
|
The initial version always enabled Google authenticator (2FA/MFA) support by
hardcoding the PAM module for sshd and login.
This change only enables the PAM module on demand if any use has 2FA/MFA
configured. Enabling the module is done system wide via pam-auth-update by
using a predefined template.
Can be tested using:
set system login user vyos authentication plaintext-password vyos
set system login user vyos authentication otp key 'QY735IG5HDHBFHS5W7Y2A4EM274SMT3O'
See https://docs.vyos.io/en/latest/configuration/system/login.html for additional
details.
|
|
accel-ppp: T5688: Standardized pool configuration in accel-ppp
|
|
Standardized pool configuration for all accel-ppp services.
1. Only named pools are used now.
2. Allows all services to use range in x.x.x.x/mask
and x.x.x.x-x.x.x.y format
3. next-pool can be used in all services
2. Allows to use in ipoe gw-ip-address without pool configuration
which allows to use Fraimed-IP-Address attribute by radius.
3. Default pool name should be explicidly configured
with default-pool.
4. In ipoe netmask and range subnet can be different.
|
|
ddclient: T5791: Simplify and fix migration script for dynamic dns
|
|
Mark 'dns dynamic name' as tag node to avoid unexpected nesting.
|
|
vti: T5769: restore interface settings on down -> up event
|
|
|
|
On VTI interface link down the link-local IPv6 address is removed. As soon as
the IPSec tunnel is online again, vti-up-down helper is called which only places
the interface in up state using iproute2 command
sudo ip link set vti0 up
This does not restore the IPv6 LL address. Instead use vyos.ifconfig to properly
re-initialize the VTI interface using the generic update() method.
|
|
|
|
Modify the configuration path to be consistent with the usual dialects
of VyoS configuration (wireguard, dns, firewall, etc.)
This would also shorten the configuration path and have a unified
treatment for RFC2136-based updates and other 'web-service' based updates.
While at it, add support for per-service web-options. This would allow
for probing different external URLs on a per-service basis.
|
|
|
|
http-api: T5782: use single config-mode script for https and http-api
|
|
|
|
|
|
|
|
|
|
|
|
|
|
https api: T5772: check if keys are configured unless PAM auth is enabled for GraphQL
|
|
T5637: firewall: extend rule for default-action to firewall bridge
|
|
pppoe: T5630: make MRU default to MTU if unspecified
|
|
to be able to catch logs using separte rule for default-action
|
|
This fixes the implementation in e062a8c11 ("pppoe: T5630: allow to specify MRU
in addition to already configurable MTU") and restores the bahavior that MRU
defaults to MTU if MRU is not explicitly set.
This was the behavior in VyOS 1.3.3 and below before we added ability to define
the MRU value.
|
|
Found an odd behavior on Linux and the VyOS CLI implementation. If adding VXLAN
interfaces using iproute2 the MTU differs depending on the creation syntax:
ip -4 link add vxlan100 type vxlan dstport 4789 external df unset tos inherit \
ttl 16 nolearning vnifilter local 172.16.33.201
ip -4 link add vxlan200 type vxlan id 200 dstport 4789 local 172.16.33.201 dev eth0
ip -6 link add vxlan300 type vxlan id 300 dstport 4789 local 2001:db8:1::1 dev eth0
132: vxlan300: <BROADCAST,MULTICAST> mtu 1430 qdisc noop state DOWN group default qlen 1000
link/ether 4e:fb:e3:f5:d9:59 brd ff:ff:ff:ff:ff:ff
133: vxlan200: <BROADCAST,MULTICAST> mtu 1450 qdisc noop state DOWN group default qlen 1000
link/ether 0e:4e:f4:76:59:3f brd ff:ff:ff:ff:ff:ff
134: vxlan100: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN group default qlen 1000
link/ether ba:b6:b7:0c:b1:37 brd ff:ff:ff:ff:ff:ff
VyOS always sets a default MTU of 1450 bytes which is correct for IPv4 p2p links
or multicast, but invalid for IPv6 p2p. Also this will break EVPN deployments
as ethernet bridges with MTU < 1500 bytes are less fun.
Increase default MTU to 1500 bytes. Migrate old configurations to use 1450
bytes if not specified otherwise on the CLI.
|
|
vxlan: T5753: add support for VNI filtering
|
|
http: T5762: rename "virtual-host listen-port" -> "virtual-host port"
|
|
unless PAM auth is enabled for GraphQL
|
|
This complements commit f5e43b136 ("http: T5762: api: make API socket backend
communication the one and only default") so we have a consistent port CLI node
across VyOS components.
|
|
Add ability to reboot and poweroff the system via API
curl -k --location --request POST 'https://vyos/reboot' \
--form data='{"op": "reboot", "path": ["now"]}' \
--form key='apikey'
curl -k --location --request POST 'https://vyos/poweroff' \
--form data='{"op": "poweroff", "path": ["now"]}' \
--form key='apikey'
|
|
http: T5762: api: make API socket backend communication the one and only default
|
|
|
|
Why: Smoketests fail as they can not establish IPv6 connection to uvicorn
backend server.
https://github.com/vyos/vyos-1x/pull/2481 added a bunch of new smoketests.
While debugging those failing, it was uncovered, that uvicorn only listens on
IPv4 connections
vyos@vyos# netstat -tulnp | grep 8080
(Not all processes could be identified, non-owned process info
will not be shown, you would have to be root to see it all.)
tcp 0 0 127.0.0.1:8080 0.0.0.0:* LISTEN -
As the CLI already has an option to move the API communication from an IP to a
UNIX domain socket, the best idea is to make this the default way of
communication, as we never directly talk to the API server but rather use the
NGINX reverse proxy.
|
|
In a service provider network a service provider typically supports multiple
bridge domains with overlapping vlans. One bridge domain per customer. Vlans in
each bridge domain are mapped to globally unique VXLAN VNI ranges assigned to
each customer.
Without the ability of VNI filtering, we can not provide VXLAN tunnels
with multiple tenants all requiring e.g. VLAN 10.
To Test:
set interfaces vxlan vxlan987 parameters external
set interfaces vxlan vxlan987 source-interface eth0
set interfaces vxlan vxlan987 parameters vni-filter
set interfaces vxlan vxlan987 vlan-to-vni 50 vni 10050
set interfaces vxlan vxlan987 vlan-to-vni 51 vni 10051
set interfaces vxlan vxlan987 vlan-to-vni 52 vni 10052
set interfaces vxlan vxlan987 vlan-to-vni 53 vni 10053
set interfaces vxlan vxlan987 vlan-to-vni 54 vni 10054
set interfaces vxlan vxlan987 vlan-to-vni 60 vni 10060
set interfaces vxlan vxlan987 vlan-to-vni 69 vni 10069
set interfaces bridge br0 member interface vxlan987
Add new op-mode command: show bridge vni
Interface VNI
----------- -----------
vxlan987 10050-10054
vxlan987 10060
vxlan987 10069
|
|
T5749: Swap show interfaces and show interfaces summary
|
|
By default show VRF, MAC, MTU for `show interfaces`
The original `show interfaces` moved to `show interfacces summary`
|
|
image: T4516: Added system image tools
|
|
|
|
|
|
|
|
|
|
|
|
|
|
An attempt to upgrade to 1.2.x is caught, but error is of failed
checksum verification; add check and message.
|
|
Note that this was updated for the fix in T5739.
|
|
|
|
Add op-mode "show interfaces summary"
Add MAC, VRF and MTU options:
vyos@r4# run show interfaces summary
Codes: S - State, L - Link, u - Up, D - Down, A - Admin Down
Interface IP Address MAC VRF MTU S/L Description
----------- ----------------- ----------------- ------- ----- ----- -------------
dum0 203.0.113.1/32 96:44:ad:c5:a1:a5 default 1500 u/u
eth0 192.168.122.14/24 52:54:00:f1:fd:77 default 1500 u/u WAN
eth1 192.0.2.1/24 52:54:00:04:33:2b foo 1500 u/u LAN-eth1
eth2 - 52:54:00:40:2e:af default 1504 u/u LAN-eth2
eth3 - 52:54:00:09:a4:b4 default 1500 A/D
|
|
This commit allows management of system images with either new or legacy
tools: 'add/delete/rename system image' and 'set default' are translated
appropriately on booting between images with the old and new tools.
Consequently, the warning of the initial commit of T4516 is dropped.
|
|
|
|
|
|
|