summaryrefslogtreecommitdiff
path: root/mibs/RMON-MIB.txt
blob: 983c22ef5b950425dc9d193e56825ecc0191179f (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
RMON-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
        NOTIFICATION-TYPE, mib-2, Counter32,
        Integer32, TimeTicks                   FROM SNMPv2-SMI

        TEXTUAL-CONVENTION, DisplayString      FROM SNMPv2-TC

        MODULE-COMPLIANCE, OBJECT-GROUP,
        NOTIFICATION-GROUP                     FROM SNMPv2-CONF;

--  Remote Network Monitoring MIB

rmonMibModule MODULE-IDENTITY
    LAST-UPDATED "200005110000Z"  -- 11 May, 2000
    ORGANIZATION "IETF RMON MIB Working Group"
    CONTACT-INFO
        "Steve Waldbusser
        Phone: +1-650-948-6500
        Fax:   +1-650-745-0671
        Email: waldbusser@nextbeacon.com"
    DESCRIPTION
        "Remote network monitoring devices, often called
        monitors or probes, are instruments that exist for
        the purpose of managing a network. This MIB defines
        objects for managing remote network monitoring devices."

    REVISION "200005110000Z"    -- 11 May, 2000
    DESCRIPTION
        "Reformatted into SMIv2 format.

        This version published as RFC 2819."

    REVISION "199502010000Z" -- 1 Feb, 1995
    DESCRIPTION
        "Bug fixes, clarifications and minor changes based on
        implementation experience, published as RFC1757 [18].

        Two changes were made to object definitions:

        1) A new status bit has been defined for the
        captureBufferPacketStatus object, indicating that the
        packet order within the capture buffer may not be identical to
        the packet order as received off the wire.  This bit may only

        be used for packets transmitted by the probe.  Older NMS
        applications can safely ignore this status bit, which might be
        used by newer agents.

        2) The packetMatch trap has been removed.  This trap was never
        actually 'approved' and was not added to this document along
        with the risingAlarm and fallingAlarm traps. The packetMatch
        trap could not be throttled, which could cause disruption of
        normal network traffic under some circumstances. An NMS should
        configure a risingAlarm threshold on the appropriate
        channelMatches instance if a trap is desired for a packetMatch
        event. Note that logging of packetMatch events is still
        supported--only trap generation for such events has been
        removed.

        In addition, several clarifications to individual object
        definitions have been added to assist agent and NMS
        implementors:

        - global definition of 'good packets' and 'bad packets'

        - more detailed text governing conceptual row creation and
          modification

        - instructions for probes relating to interface changes and
          disruptions

        - clarification of some ethernet counter definitions

        - recommended formula for calculating network utilization

        - clarification of channel and captureBuffer behavior for some
          unusual conditions

        - examples of proper instance naming for each table"

    REVISION "199111010000Z"    -- 1 Nov, 1991
    DESCRIPTION
        "The original version of this MIB, published as RFC1271."
    ::= { rmonConformance 8 }

    rmon    OBJECT IDENTIFIER ::= { mib-2 16 }

    -- textual conventions

OwnerString ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "This data type is used to model an administratively
        assigned name of the owner of a resource. Implementations
        must accept values composed of well-formed NVT ASCII
        sequences. In addition, implementations should accept
        values composed of well-formed UTF-8 sequences.

        It is suggested that this name contain one or more of
        the following: IP address, management station name,
        network manager's name, location, or phone number.
        In some cases the agent itself will be the owner of
        an entry.  In these cases, this string shall be set
        to a string starting with 'monitor'.

        SNMP access control is articulated entirely in terms
        of the contents of MIB views; access to a particular
        SNMP object instance depends only upon its presence
        or absence in a particular MIB view and never upon
        its value or the value of related object instances.
        Thus, objects of this type afford resolution of
        resource contention only among cooperating
        managers; they realize no access control function
        with respect to uncooperative parties."
    SYNTAX OCTET STRING (SIZE (0..127))

EntryStatus ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The status of a table entry.

        Setting this object to the value invalid(4) has the
        effect of invalidating the corresponding entry.
        That is, it effectively disassociates the mapping
        identified with said entry.
        It is an implementation-specific matter as to whether
        the agent removes an invalidated entry from the table.
        Accordingly, management stations must be prepared to
        receive tabular information from agents that corresponds
        to entries currently not in use.  Proper
        interpretation of such entries requires examination
        of the relevant EntryStatus object.

        An existing instance of this object cannot be set to
        createRequest(2).  This object may only be set to
        createRequest(2) when this instance is created.  When
        this object is created, the agent may wish to create
        supplemental object instances with default values
        to complete a conceptual row in this table.  Because the

        creation of these default objects is entirely at the option
        of the agent, the manager must not assume that any will be
        created, but may make use of any that are created.
        Immediately after completing the create operation, the agent
        must set this object to underCreation(3).

        When in the underCreation(3) state, an entry is allowed to
        exist in a possibly incomplete, possibly inconsistent state,
        usually to allow it to be modified in multiple PDUs.  When in
        this state, an entry is not fully active.
        Entries shall exist in the underCreation(3) state until
        the management station is finished configuring the entry
        and sets this object to valid(1) or aborts, setting this
        object to invalid(4).  If the agent determines that an
        entry has been in the underCreation(3) state for an
        abnormally long time, it may decide that the management
        station has crashed.  If the agent makes this decision,
        it may set this object to invalid(4) to reclaim the
        entry.  A prudent agent will understand that the
        management station may need to wait for human input
        and will allow for that possibility in its
        determination of this abnormally long period.

        An entry in the valid(1) state is fully configured and
        consistent and fully represents the configuration or
        operation such a row is intended to represent.  For
        example, it could be a statistical function that is
        configured and active, or a filter that is available
        in the list of filters processed by the packet capture
        process.

        A manager is restricted to changing the state of an entry in
        the following ways:

             To:       valid  createRequest  underCreation  invalid
        From:
        valid             OK             NO             OK       OK
        createRequest    N/A            N/A            N/A      N/A
        underCreation     OK             NO             OK       OK
        invalid           NO             NO             NO       OK
        nonExistent       NO             OK             NO       OK

        In the table above, it is not applicable to move the state
        from the createRequest state to any other state because the
        manager will never find the variable in that state.  The
        nonExistent state is not a value of the enumeration, rather
        it means that the entryStatus variable does not exist at all.

        An agent may allow an entryStatus variable to change state in
        additional ways, so long as the semantics of the states are
        followed.  This allowance is made to ease the implementation of
        the agent and is made despite the fact that managers should
        never exercise these additional state transitions."
    SYNTAX INTEGER {
               valid(1),
               createRequest(2),
               underCreation(3),
               invalid(4)
           }

    statistics        OBJECT IDENTIFIER ::= { rmon 1 }
    history           OBJECT IDENTIFIER ::= { rmon 2 }
    alarm             OBJECT IDENTIFIER ::= { rmon 3 }
    hosts             OBJECT IDENTIFIER ::= { rmon 4 }
    hostTopN          OBJECT IDENTIFIER ::= { rmon 5 }
    matrix            OBJECT IDENTIFIER ::= { rmon 6 }
    filter            OBJECT IDENTIFIER ::= { rmon 7 }
    capture           OBJECT IDENTIFIER ::= { rmon 8 }
    event             OBJECT IDENTIFIER ::= { rmon 9 }
    rmonConformance   OBJECT IDENTIFIER ::= { rmon 20 }

-- The Ethernet Statistics Group
--
-- Implementation of the Ethernet Statistics group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The ethernet statistics group contains statistics measured by the
-- probe for each monitored interface on this device.  These
-- statistics take the form of free running counters that start from
-- zero when a valid entry is created.
--
-- This group currently has statistics defined only for
-- Ethernet interfaces.  Each etherStatsEntry contains statistics
-- for one Ethernet interface.  The probe must create one
-- etherStats entry for each monitored Ethernet interface
-- on the device.

etherStatsTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF EtherStatsEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of Ethernet statistics entries."
    ::= { statistics 1 }

etherStatsEntry OBJECT-TYPE
    SYNTAX     EtherStatsEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A collection of statistics kept for a particular
        Ethernet interface.  As an example, an instance of the
        etherStatsPkts object might be named etherStatsPkts.1"
    INDEX { etherStatsIndex }
    ::= { etherStatsTable 1 }

EtherStatsEntry ::= SEQUENCE {
    etherStatsIndex                    Integer32,
    etherStatsDataSource               OBJECT IDENTIFIER,
    etherStatsDropEvents               Counter32,
    etherStatsOctets                   Counter32,
    etherStatsPkts                     Counter32,
    etherStatsBroadcastPkts            Counter32,
    etherStatsMulticastPkts            Counter32,
    etherStatsCRCAlignErrors           Counter32,
    etherStatsUndersizePkts            Counter32,
    etherStatsOversizePkts             Counter32,
    etherStatsFragments                Counter32,
    etherStatsJabbers                  Counter32,
    etherStatsCollisions               Counter32,
    etherStatsPkts64Octets             Counter32,
    etherStatsPkts65to127Octets        Counter32,
    etherStatsPkts128to255Octets       Counter32,
    etherStatsPkts256to511Octets       Counter32,
    etherStatsPkts512to1023Octets      Counter32,
    etherStatsPkts1024to1518Octets     Counter32,
    etherStatsOwner                    OwnerString,
    etherStatsStatus                   EntryStatus
}

etherStatsIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of this object uniquely identifies this
        etherStats entry."
    ::= { etherStatsEntry 1 }

etherStatsDataSource OBJECT-TYPE
    SYNTAX     OBJECT IDENTIFIER
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object identifies the source of the data that
        this etherStats entry is configured to analyze.  This
        source can be any ethernet interface on this device.
        In order to identify a particular interface, this object
        shall identify the instance of the ifIndex object,
        defined in RFC 2233 [17], for the desired interface.
        For example, if an entry were to receive data from
        interface #1, this object would be set to ifIndex.1.

        The statistics in this group reflect all packets
        on the local network segment attached to the identified
        interface.

        An agent may or may not be able to tell if fundamental
        changes to the media of the interface have occurred and
        necessitate an invalidation of this entry.  For example, a
        hot-pluggable ethernet card could be pulled out and replaced
        by a token-ring card.  In such a case, if the agent has such
        knowledge of the change, it is recommended that it
        invalidate this entry.

        This object may not be modified if the associated
        etherStatsStatus object is equal to valid(1)."
    ::= { etherStatsEntry 2 }

etherStatsDropEvents OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of events in which packets
        were dropped by the probe due to lack of resources.
        Note that this number is not necessarily the number of
        packets dropped; it is just the number of times this
        condition has been detected."
    ::= { etherStatsEntry 3 }

etherStatsOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of octets of data (including
        those in bad packets) received on the
        network (excluding framing bits but including
        FCS octets).

        This object can be used as a reasonable estimate of
        10-Megabit ethernet utilization.  If greater precision is
        desired, the etherStatsPkts and etherStatsOctets objects
        should be sampled before and after a common interval.  The
        differences in the sampled values are Pkts and Octets,
        respectively, and the number of seconds in the interval is
        Interval.  These values are used to calculate the Utilization
        as follows:

                         Pkts * (9.6 + 6.4) + (Octets * .8)
         Utilization = -------------------------------------
                                 Interval * 10,000

        The result of this equation is the value Utilization which
        is the percent utilization of the ethernet segment on a
        scale of 0 to 100 percent."
    ::= { etherStatsEntry 4 }

etherStatsPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad packets,
        broadcast packets, and multicast packets) received."
    ::= { etherStatsEntry 5 }

etherStatsBroadcastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets received that were
        directed to the broadcast address.  Note that this
        does not include multicast packets."
    ::= { etherStatsEntry 6 }

etherStatsMulticastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of good packets received that were
        directed to a multicast address.  Note that this number
        does not include packets directed to the broadcast

        address."
    ::= { etherStatsEntry 7 }

etherStatsCRCAlignErrors OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that
        had a length (excluding framing bits, but
        including FCS octets) of between 64 and 1518
        octets, inclusive, but had either a bad
        Frame Check Sequence (FCS) with an integral
        number of octets (FCS Error) or a bad FCS with
        a non-integral number of octets (Alignment Error)."
    ::= { etherStatsEntry 8 }

etherStatsUndersizePkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that were
        less than 64 octets long (excluding framing bits,
        but including FCS octets) and were otherwise well
        formed."
    ::= { etherStatsEntry 9 }

etherStatsOversizePkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that were
        longer than 1518 octets (excluding framing bits,
        but including FCS octets) and were otherwise
        well formed."
    ::= { etherStatsEntry 10 }

etherStatsFragments OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that were less than
        64 octets in length (excluding framing bits but including
        FCS octets) and had either a bad Frame Check Sequence
        (FCS) with an integral number of octets (FCS Error) or a
        bad FCS with a non-integral number of octets (Alignment
        Error).

        Note that it is entirely normal for etherStatsFragments to
        increment.  This is because it counts both runts (which are
        normal occurrences due to collisions) and noise hits."
    ::= { etherStatsEntry 11 }

etherStatsJabbers OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received that were
        longer than 1518 octets (excluding framing bits,
        but including FCS octets), and had either a bad
        Frame Check Sequence (FCS) with an integral number
        of octets (FCS Error) or a bad FCS with a non-integral
        number of octets (Alignment Error).

        Note that this definition of jabber is different
        than the definition in IEEE-802.3 section 8.2.1.5
        (10BASE5) and section 10.3.1.4 (10BASE2).  These
        documents define jabber as the condition where any
        packet exceeds 20 ms.  The allowed range to detect
        jabber is between 20 ms and 150 ms."
    ::= { etherStatsEntry 12 }

etherStatsCollisions OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Collisions"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The best estimate of the total number of collisions
        on this Ethernet segment.

        The value returned will depend on the location of the
        RMON probe. Section 8.2.1.3 (10BASE-5) and section
        10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
        station must detect a collision, in the receive mode, if
        three or more stations are transmitting simultaneously.  A
        repeater port must detect a collision when two or more

        stations are transmitting simultaneously.  Thus a probe
        placed on a repeater port could record more collisions
        than a probe connected to a station on the same segment
        would.

        Probe location plays a much smaller role when considering
        10BASE-T.  14.2.1.4 (10BASE-T) of IEEE standard 802.3
        defines a collision as the simultaneous presence of signals
        on the DO and RD circuits (transmitting and receiving
        at the same time).  A 10BASE-T station can only detect
        collisions when it is transmitting.  Thus probes placed on
        a station and a repeater, should report the same number of
        collisions.

        Note also that an RMON probe inside a repeater should
        ideally report collisions between the repeater and one or
        more other hosts (transmit collisions as defined by IEEE
        802.3k) plus receiver collisions observed on any coax
        segments to which the repeater is connected."
    ::= { etherStatsEntry 13 }

etherStatsPkts64Octets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad
        packets) received that were 64 octets in length
        (excluding framing bits but including FCS octets)."
    ::= { etherStatsEntry 14 }

etherStatsPkts65to127Octets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad
        packets) received that were between
        65 and 127 octets in length inclusive
        (excluding framing bits but including FCS octets)."
    ::= { etherStatsEntry 15 }

etherStatsPkts128to255Octets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad
        packets) received that were between
        128 and 255 octets in length inclusive
        (excluding framing bits but including FCS octets)."
    ::= { etherStatsEntry 16 }

etherStatsPkts256to511Octets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad
        packets) received that were between
        256 and 511 octets in length inclusive
        (excluding framing bits but including FCS octets)."
    ::= { etherStatsEntry 17 }

etherStatsPkts512to1023Octets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad
        packets) received that were between
        512 and 1023 octets in length inclusive
        (excluding framing bits but including FCS octets)."
    ::= { etherStatsEntry 18 }

etherStatsPkts1024to1518Octets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets (including bad
        packets) received that were between
        1024 and 1518 octets in length inclusive
        (excluding framing bits but including FCS octets)."
    ::= { etherStatsEntry 19 }

etherStatsOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { etherStatsEntry 20 }

etherStatsStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this etherStats entry."
    ::= { etherStatsEntry 21 }

-- The History Control Group

-- Implementation of the History Control group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The history control group controls the periodic statistical
-- sampling of data from various types of networks.  The
-- historyControlTable stores configuration entries that each
-- define an interface, polling period, and other parameters.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table.  Each such entry defines one
-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken.  Each counter in the
-- etherHistoryEntry counts the same event as its similarly-named
-- counterpart in the etherStatsEntry, except that each value here
-- is a cumulative sum during a sampling period.
--
-- If the probe keeps track of the time of day, it should start
-- the first sample of the history at a time such that
-- when the next hour of the day begins, a sample is
-- started at that instant.  This tends to make more
-- user-friendly reports, and enables comparison of reports
-- from different probes that have relatively accurate time
-- of day.
--
-- The probe is encouraged to add two history control entries
-- per monitored interface upon initialization that describe a short
-- term and a long term polling period.  Suggested parameters are 30
-- seconds for the short term polling period and 30 minutes for
-- the long term period.

historyControlTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF HistoryControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of history control entries."
    ::= { history 1 }

historyControlEntry OBJECT-TYPE
    SYNTAX     HistoryControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of parameters that set up a periodic sampling of
        statistics.  As an example, an instance of the
        historyControlInterval object might be named
        historyControlInterval.2"
    INDEX { historyControlIndex }
    ::= { historyControlTable 1 }

HistoryControlEntry ::= SEQUENCE {
    historyControlIndex             Integer32,
    historyControlDataSource        OBJECT IDENTIFIER,
    historyControlBucketsRequested  Integer32,
    historyControlBucketsGranted    Integer32,
    historyControlInterval          Integer32,
    historyControlOwner             OwnerString,
    historyControlStatus            EntryStatus
}

historyControlIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in the
        historyControl table.  Each such entry defines a
        set of samples at a particular interval for an
        interface on the device."
    ::= { historyControlEntry 1 }

historyControlDataSource OBJECT-TYPE
    SYNTAX     OBJECT IDENTIFIER
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object identifies the source of the data for
        which historical data was collected and
        placed in a media-specific table on behalf of this
        historyControlEntry.  This source can be any
        interface on this device.  In order to identify

        a particular interface, this object shall identify
        the instance of the ifIndex object, defined
        in  RFC 2233 [17], for the desired interface.
        For example, if an entry were to receive data from
        interface #1, this object would be set to ifIndex.1.

        The statistics in this group reflect all packets
        on the local network segment attached to the identified
        interface.

        An agent may or may not be able to tell if fundamental
        changes to the media of the interface have occurred and
        necessitate an invalidation of this entry.  For example, a
        hot-pluggable ethernet card could be pulled out and replaced
        by a token-ring card.  In such a case, if the agent has such
        knowledge of the change, it is recommended that it
        invalidate this entry.

        This object may not be modified if the associated
        historyControlStatus object is equal to valid(1)."
    ::= { historyControlEntry 2 }

historyControlBucketsRequested OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The requested number of discrete time intervals
        over which data is to be saved in the part of the
        media-specific table associated with this
        historyControlEntry.

        When this object is created or modified, the probe
        should set historyControlBucketsGranted as closely to
        this object as is possible for the particular probe
        implementation and available resources."
    DEFVAL { 50 }
    ::= { historyControlEntry 3 }

historyControlBucketsGranted OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of discrete sampling intervals
        over which data shall be saved in the part of
        the media-specific table associated with this
        historyControlEntry.

        When the associated historyControlBucketsRequested
        object is created or modified, the probe
        should set this object as closely to the requested
        value as is possible for the particular
        probe implementation and available resources.  The
        probe must not lower this value except as a result
        of a modification to the associated
        historyControlBucketsRequested object.

        There will be times when the actual number of
        buckets associated with this entry is less than
        the value of this object.  In this case, at the
        end of each sampling interval, a new bucket will
        be added to the media-specific table.

        When the number of buckets reaches the value of
        this object and a new bucket is to be added to the
        media-specific table, the oldest bucket associated
        with this historyControlEntry shall be deleted by
        the agent so that the new bucket can be added.

        When the value of this object changes to a value less
        than the current value, entries are deleted
        from the media-specific table associated with this
        historyControlEntry.  Enough of the oldest of these
        entries shall be deleted by the agent so that their
        number remains less than or equal to the new value of
        this object.

        When the value of this object changes to a value greater
        than the current value, the number of associated media-
        specific entries may be allowed to grow."
    ::= { historyControlEntry 4 }

historyControlInterval OBJECT-TYPE
    SYNTAX     Integer32 (1..3600)
    UNITS      "Seconds"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The interval in seconds over which the data is
        sampled for each bucket in the part of the
        media-specific table associated with this
        historyControlEntry.  This interval can
        be set to any number of seconds between 1 and
        3600 (1 hour).

        Because the counters in a bucket may overflow at their

        maximum value with no indication, a prudent manager will
        take into account the possibility of overflow in any of
        the associated counters.  It is important to consider the
        minimum time in which any counter could overflow on a
        particular media type and set the historyControlInterval
        object to a value less than this interval.  This is
        typically most important for the 'octets' counter in any
        media-specific table.  For example, on an Ethernet
        network, the etherHistoryOctets counter could overflow
        in about one hour at the Ethernet's maximum
        utilization.

        This object may not be modified if the associated
        historyControlStatus object is equal to valid(1)."
    DEFVAL { 1800 }
    ::= { historyControlEntry 5 }

historyControlOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { historyControlEntry 6 }

historyControlStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this historyControl entry.

        Each instance of the media-specific table associated
        with this historyControlEntry will be deleted by the agent
        if this historyControlEntry is not equal to valid(1)."
    ::= { historyControlEntry 7 }

-- The Ethernet History Group

-- Implementation of the Ethernet History group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Ethernet History group records periodic statistical samples
-- from a network and stores them for later retrieval.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table.  Each such entry defines one

-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken.  This group defines the
-- etherHistoryTable, for Ethernet networks.
--

etherHistoryTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF EtherHistoryEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of Ethernet history entries."
    ::= { history 2 }

etherHistoryEntry OBJECT-TYPE
    SYNTAX     EtherHistoryEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "An historical sample of Ethernet statistics on a particular
        Ethernet interface.  This sample is associated with the
        historyControlEntry which set up the parameters for
        a regular collection of these samples.  As an example, an
        instance of the etherHistoryPkts object might be named
        etherHistoryPkts.2.89"
    INDEX { etherHistoryIndex , etherHistorySampleIndex }
    ::= { etherHistoryTable 1 }

EtherHistoryEntry ::= SEQUENCE {
    etherHistoryIndex                 Integer32,
    etherHistorySampleIndex           Integer32,
    etherHistoryIntervalStart         TimeTicks,
    etherHistoryDropEvents            Counter32,
    etherHistoryOctets                Counter32,
    etherHistoryPkts                  Counter32,
    etherHistoryBroadcastPkts         Counter32,
    etherHistoryMulticastPkts         Counter32,
    etherHistoryCRCAlignErrors        Counter32,
    etherHistoryUndersizePkts         Counter32,
    etherHistoryOversizePkts          Counter32,
    etherHistoryFragments             Counter32,
    etherHistoryJabbers               Counter32,
    etherHistoryCollisions            Counter32,
    etherHistoryUtilization           Integer32
}

etherHistoryIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The history of which this entry is a part.  The
        history identified by a particular value of this
        index is the same history as identified
        by the same value of historyControlIndex."
    ::= { etherHistoryEntry 1 }

etherHistorySampleIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..2147483647)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies the particular
        sample this entry represents among all samples
        associated with the same historyControlEntry.
        This index starts at 1 and increases by one
        as each new sample is taken."
    ::= { etherHistoryEntry 2 }

etherHistoryIntervalStart OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime at the start of the interval
        over which this sample was measured.  If the probe
        keeps track of the time of day, it should start
        the first sample of the history at a time such that
        when the next hour of the day begins, a sample is
        started at that instant.  Note that following this
        rule may require the probe to delay collecting the
        first sample of the history, as each sample must be
        of the same interval.  Also note that the sample which
        is currently being collected is not accessible in this
        table until the end of its interval."
    ::= { etherHistoryEntry 3 }

etherHistoryDropEvents OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of events in which packets
        were dropped by the probe due to lack of resources
        during this sampling interval.  Note that this number
        is not necessarily the number of packets dropped, it
        is just the number of times this condition has been

        detected."
    ::= { etherHistoryEntry 4 }

etherHistoryOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of octets of data (including
        those in bad packets) received on the
        network (excluding framing bits but including
        FCS octets)."
    ::= { etherHistoryEntry 5 }

etherHistoryPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets (including bad packets)
        received during this sampling interval."
    ::= { etherHistoryEntry 6 }

etherHistoryBroadcastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets received during this
        sampling interval that were directed to the
        broadcast address."
    ::= { etherHistoryEntry 7 }

etherHistoryMulticastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets received during this
        sampling interval that were directed to a
        multicast address.  Note that this number does not
        include packets addressed to the broadcast address."
    ::= { etherHistoryEntry 8 }

etherHistoryCRCAlignErrors OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets received during this
        sampling interval that had a length (excluding
        framing bits but including FCS octets) between
        64 and 1518 octets, inclusive, but had either a bad Frame
        Check Sequence (FCS) with an integral number of octets
        (FCS Error) or a bad FCS with a non-integral number
        of octets (Alignment Error)."
    ::= { etherHistoryEntry 9 }

etherHistoryUndersizePkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets received during this
        sampling interval that were less than 64 octets
        long (excluding framing bits but including FCS
        octets) and were otherwise well formed."
    ::= { etherHistoryEntry 10 }

etherHistoryOversizePkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets received during this
        sampling interval that were longer than 1518
        octets (excluding framing bits but including
        FCS octets) but were otherwise well formed."
    ::= { etherHistoryEntry 11 }

etherHistoryFragments OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The total number of packets received during this
        sampling interval that were less than 64 octets in
        length (excluding framing bits but including FCS

        octets) had either a bad Frame Check Sequence (FCS)
        with an integral number of octets (FCS Error) or a bad
        FCS with a non-integral number of octets (Alignment
        Error).

        Note that it is entirely normal for etherHistoryFragments to
        increment.  This is because it counts both runts (which are
        normal occurrences due to collisions) and noise hits."
    ::= { etherHistoryEntry 12 }

etherHistoryJabbers OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets received during this
        sampling interval that were longer than 1518 octets
        (excluding framing bits but including FCS octets),
        and  had either a bad Frame Check Sequence (FCS)
        with an integral number of octets (FCS Error) or
        a bad FCS with a non-integral number of octets
        (Alignment Error).

        Note that this definition of jabber is different
        than the definition in IEEE-802.3 section 8.2.1.5
        (10BASE5) and section 10.3.1.4 (10BASE2).  These
        documents define jabber as the condition where any
        packet exceeds 20 ms.  The allowed range to detect
        jabber is between 20 ms and 150 ms."
    ::= { etherHistoryEntry 13 }

etherHistoryCollisions OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Collisions"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The best estimate of the total number of collisions
        on this Ethernet segment during this sampling
        interval.

        The value returned will depend on the location of the
        RMON probe. Section 8.2.1.3 (10BASE-5) and section
        10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
        station must detect a collision, in the receive mode, if
        three or more stations are transmitting simultaneously.  A
        repeater port must detect a collision when two or more

        stations are transmitting simultaneously.  Thus a probe
        placed on a repeater port could record more collisions
        than a probe connected to a station on the same segment
        would.

        Probe location plays a much smaller role when considering
        10BASE-T.  14.2.1.4 (10BASE-T) of IEEE standard 802.3
        defines a collision as the simultaneous presence of signals
        on the DO and RD circuits (transmitting and receiving
        at the same time).  A 10BASE-T station can only detect
        collisions when it is transmitting.  Thus probes placed on
        a station and a repeater, should report the same number of
        collisions.

        Note also that an RMON probe inside a repeater should
        ideally report collisions between the repeater and one or
        more other hosts (transmit collisions as defined by IEEE
        802.3k) plus receiver collisions observed on any coax
        segments to which the repeater is connected."
    ::= { etherHistoryEntry 14 }

etherHistoryUtilization OBJECT-TYPE
    SYNTAX     Integer32 (0..10000)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The best estimate of the mean physical layer
        network utilization on this interface during this
        sampling interval, in hundredths of a percent."
    ::= { etherHistoryEntry 15 }

-- The Alarm Group

-- Implementation of the Alarm group is optional. The Alarm Group
-- requires the implementation of the Event group.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Alarm group periodically takes statistical samples from
-- variables in the probe and compares them to thresholds that have
-- been configured.  The alarm table stores configuration
-- entries that each define a variable, polling period, and
-- threshold parameters.  If a sample is found to cross the
-- threshold values, an event is generated.  Only variables that
-- resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32,
-- Counter32, Counter64, Gauge32, or TimeTicks) may be monitored in
-- this way.
--

-- This function has a hysteresis mechanism to limit the generation
-- of events.  This mechanism generates one event as a threshold
-- is crossed in the appropriate direction.  No more events are
-- generated for that threshold until the opposite threshold is
-- crossed.
--
-- In the case of a sampling a deltaValue, a probe may implement
-- this mechanism with more precision if it takes a delta sample
-- twice per period, each time comparing the sum of the latest two
-- samples to the threshold.  This allows the detection of threshold
-- crossings that span the sampling boundary.  Note that this does
-- not require any special configuration of the threshold value.
-- It is suggested that probes implement this more precise algorithm.

alarmTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF AlarmEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of alarm entries."
    ::= { alarm 1 }

alarmEntry OBJECT-TYPE
    SYNTAX     AlarmEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of parameters that set up a periodic checking
        for alarm conditions.  For example, an instance of the
        alarmValue object might be named alarmValue.8"
    INDEX { alarmIndex }
    ::= { alarmTable 1 }

AlarmEntry ::= SEQUENCE {
    alarmIndex                    Integer32,
    alarmInterval                 Integer32,
    alarmVariable                 OBJECT IDENTIFIER,
    alarmSampleType               INTEGER,
    alarmValue                    Integer32,
    alarmStartupAlarm             INTEGER,
    alarmRisingThreshold          Integer32,
    alarmFallingThreshold         Integer32,
    alarmRisingEventIndex         Integer32,
    alarmFallingEventIndex        Integer32,
    alarmOwner                    OwnerString,
    alarmStatus                   EntryStatus
}

alarmIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in the
        alarm table.  Each such entry defines a
        diagnostic sample at a particular interval
        for an object on the device."
    ::= { alarmEntry 1 }

alarmInterval OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Seconds"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The interval in seconds over which the data is
        sampled and compared with the rising and falling
        thresholds.  When setting this variable, care
        should be taken in the case of deltaValue
        sampling - the interval should be set short enough
        that the sampled variable is very unlikely to
        increase or decrease by more than 2^31 - 1 during
        a single sampling interval.

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 2 }

alarmVariable OBJECT-TYPE
    SYNTAX     OBJECT IDENTIFIER
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The object identifier of the particular variable to be
        sampled.  Only variables that resolve to an ASN.1 primitive
        type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
        Gauge, or TimeTicks) may be sampled.

        Because SNMP access control is articulated entirely
        in terms of the contents of MIB views, no access
        control mechanism exists that can restrict the value of
        this object to identify only those objects that exist
        in a particular MIB view.  Because there is thus no
        acceptable means of restricting the read access that
        could be obtained through the alarm mechanism, the
        probe must only grant write access to this object in

        those views that have read access to all objects on
        the probe.

        During a set operation, if the supplied variable name is
        not available in the selected MIB view, a badValue error
        must be returned.  If at any time the variable name of
        an established alarmEntry is no longer available in the
        selected MIB view, the probe must change the status of
        this alarmEntry to invalid(4).

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 3 }

alarmSampleType OBJECT-TYPE
    SYNTAX     INTEGER {
                 absoluteValue(1),
                 deltaValue(2)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The method of sampling the selected variable and
        calculating the value to be compared against the
        thresholds.  If the value of this object is
        absoluteValue(1), the value of the selected variable
        will be compared directly with the thresholds at the
        end of the sampling interval.  If the value of this
        object is deltaValue(2), the value of the selected
        variable at the last sample will be subtracted from
        the current value, and the difference compared with
        the thresholds.

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 4 }

alarmValue OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of the statistic during the last sampling
        period.  For example, if the sample type is deltaValue,
        this value will be the difference between the samples
        at the beginning and end of the period.  If the sample
        type is absoluteValue, this value will be the sampled
        value at the end of the period.

        This is the value that is compared with the rising and
        falling thresholds.

        The value during the current sampling period is not
        made available until the period is completed and will
        remain available until the next period completes."
    ::= { alarmEntry 5 }

alarmStartupAlarm OBJECT-TYPE
    SYNTAX     INTEGER {
                 risingAlarm(1),
                 fallingAlarm(2),
                 risingOrFallingAlarm(3)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The alarm that may be sent when this entry is first
        set to valid.  If the first sample after this entry
        becomes valid is greater than or equal to the
        risingThreshold and alarmStartupAlarm is equal to
        risingAlarm(1) or risingOrFallingAlarm(3), then a single
        rising alarm will be generated.  If the first sample
        after this entry becomes valid is less than or equal
        to the fallingThreshold and alarmStartupAlarm is equal
        to fallingAlarm(2) or risingOrFallingAlarm(3), then a
        single falling alarm will be generated.

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 6 }

alarmRisingThreshold OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "A threshold for the sampled statistic.  When the current
        sampled value is greater than or equal to this threshold,
        and the value at the last sampling interval was less than
        this threshold, a single event will be generated.
        A single event will also be generated if the first
        sample after this entry becomes valid is greater than or
        equal to this threshold and the associated
        alarmStartupAlarm is equal to risingAlarm(1) or
        risingOrFallingAlarm(3).

        After a rising event is generated, another such event

        will not be generated until the sampled value
        falls below this threshold and reaches the
        alarmFallingThreshold.

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 7 }

alarmFallingThreshold OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "A threshold for the sampled statistic.  When the current
        sampled value is less than or equal to this threshold,
        and the value at the last sampling interval was greater than
        this threshold, a single event will be generated.
        A single event will also be generated if the first
        sample after this entry becomes valid is less than or
        equal to this threshold and the associated
        alarmStartupAlarm is equal to fallingAlarm(2) or
        risingOrFallingAlarm(3).

        After a falling event is generated, another such event
        will not be generated until the sampled value
        rises above this threshold and reaches the
        alarmRisingThreshold.

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 8 }

alarmRisingEventIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The index of the eventEntry that is
        used when a rising threshold is crossed.  The
        eventEntry identified by a particular value of
        this index is the same as identified by the same value
        of the eventIndex object.  If there is no
        corresponding entry in the eventTable, then
        no association exists.  In particular, if this value
        is zero, no associated event will be generated, as
        zero is not a valid event index.

        This object may not be modified if the associated

        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 9 }

alarmFallingEventIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The index of the eventEntry that is
        used when a falling threshold is crossed.  The
        eventEntry identified by a particular value of
        this index is the same as identified by the same value
        of the eventIndex object.  If there is no
        corresponding entry in the eventTable, then
        no association exists.  In particular, if this value
        is zero, no associated event will be generated, as
        zero is not a valid event index.

        This object may not be modified if the associated
        alarmStatus object is equal to valid(1)."
    ::= { alarmEntry 10 }

alarmOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { alarmEntry 11 }

alarmStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this alarm entry."
    ::= { alarmEntry 12 }

-- The Host Group

-- Implementation of the Host group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The host group discovers new hosts on the network by
-- keeping a list of source and destination MAC Addresses seen
-- in good packets.  For each of these addresses, the host group

-- keeps a set of statistics.  The hostControlTable controls
-- which interfaces this function is performed on, and contains
-- some information about the process.  On behalf of each
-- hostControlEntry, data is collected on an interface and placed
-- in both the hostTable and the hostTimeTable.  If the
-- monitoring device finds itself short of resources, it may
-- delete entries as needed.  It is suggested that the device
-- delete the least recently used entries first.

-- The hostTable contains entries for each address discovered on
-- a particular interface.  Each entry contains statistical
-- data about that host.  This table is indexed by the
-- MAC address of the host, through which a random access
-- may be achieved.

-- The hostTimeTable contains data in the same format as the
-- hostTable, and must contain the same set of hosts, but is
-- indexed using hostTimeCreationOrder rather than hostAddress.
-- The hostTimeCreationOrder is an integer which reflects
-- the relative order in which a particular entry was discovered
-- and thus inserted into the table.  As this order, and thus
-- the index, is among those entries currently in the table,
-- the index for a particular entry may change if an
-- (earlier) entry is deleted.  Thus the association between
-- hostTimeCreationOrder and hostTimeEntry may be broken at
-- any time.

-- The hostTimeTable has two important uses.  The first is the
-- fast download of this potentially large table.  Because the
-- index of this table runs from 1 to the size of the table,
-- inclusive, its values are predictable.  This allows very
-- efficient packing of variables into SNMP PDU's and allows
-- a table transfer to have multiple packets outstanding.
-- These benefits increase transfer rates tremendously.

-- The second use of the hostTimeTable is the efficient discovery
-- by the management station of new entries added to the table.
-- After the management station has downloaded the entire table,
-- it knows that new entries will be added immediately after the
-- end of the current table.  It can thus detect new entries there
-- and retrieve them easily.

-- Because the association between hostTimeCreationOrder and
-- hostTimeEntry may be broken at any time, the management
-- station must monitor the related hostControlLastDeleteTime
-- object.  When the management station thus detects a deletion,
-- it must assume that any such associations have been broken,
-- and invalidate any it has stored locally.  This includes

-- restarting any download of the hostTimeTable that may have been
-- in progress, as well as rediscovering the end of the
-- hostTimeTable so that it may detect new entries.  If the
-- management station does not detect the broken association,
-- it may continue to refer to a particular host by its
-- creationOrder while unwittingly retrieving the data associated
-- with another host entirely.  If this happens while downloading
-- the host table, the management station may fail to download
-- all of the entries in the table.

hostControlTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF HostControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of host table control entries."
    ::= { hosts 1 }

hostControlEntry OBJECT-TYPE
    SYNTAX     HostControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of parameters that set up the discovery of hosts
        on a particular interface and the collection of statistics
        about these hosts.  For example, an instance of the
        hostControlTableSize object might be named
        hostControlTableSize.1"
    INDEX { hostControlIndex }
    ::= { hostControlTable 1 }

HostControlEntry ::= SEQUENCE {

    hostControlIndex            Integer32,
    hostControlDataSource       OBJECT IDENTIFIER,
    hostControlTableSize        Integer32,
    hostControlLastDeleteTime   TimeTicks,
    hostControlOwner            OwnerString,
    hostControlStatus           EntryStatus
}

hostControlIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in the

        hostControl table.  Each such entry defines
        a function that discovers hosts on a particular interface
        and places statistics about them in the hostTable and
        the hostTimeTable on behalf of this hostControlEntry."
    ::= { hostControlEntry 1 }

hostControlDataSource OBJECT-TYPE
    SYNTAX     OBJECT IDENTIFIER
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object identifies the source of the data for
        this instance of the host function.  This source
        can be any interface on this device.  In order
        to identify a particular interface, this object shall
        identify the instance of the ifIndex object, defined
        in RFC 2233 [17], for the desired interface.
        For example, if an entry were to receive data from
        interface #1, this object would be set to ifIndex.1.

        The statistics in this group reflect all packets
        on the local network segment attached to the identified
        interface.

        An agent may or may not be able to tell if fundamental
        changes to the media of the interface have occurred and
        necessitate an invalidation of this entry.  For example, a
        hot-pluggable ethernet card could be pulled out and replaced
        by a token-ring card.  In such a case, if the agent has such
        knowledge of the change, it is recommended that it
        invalidate this entry.

        This object may not be modified if the associated
        hostControlStatus object is equal to valid(1)."
    ::= { hostControlEntry 2 }

hostControlTableSize OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of hostEntries in the hostTable and the
        hostTimeTable associated with this hostControlEntry."
    ::= { hostControlEntry 3 }

hostControlLastDeleteTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime when the last entry
        was deleted from the portion of the hostTable
        associated with this hostControlEntry.  If no
        deletions have occurred, this value shall be zero."
    ::= { hostControlEntry 4 }

hostControlOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { hostControlEntry 5 }

hostControlStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this hostControl entry.

        If this object is not equal to valid(1), all associated
        entries in the hostTable, hostTimeTable, and the
        hostTopNTable shall be deleted by the agent."
    ::= { hostControlEntry 6 }

hostTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF HostEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of host entries."
    ::= { hosts 2 }

hostEntry OBJECT-TYPE
    SYNTAX     HostEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A collection of statistics for a particular host that has
        been discovered on an interface of this device.  For example,
        an instance of the hostOutBroadcastPkts object might be
        named hostOutBroadcastPkts.1.6.8.0.32.27.3.176"
    INDEX { hostIndex, hostAddress }
    ::= { hostTable 1 }

HostEntry ::= SEQUENCE {
    hostAddress             OCTET STRING,
    hostCreationOrder       Integer32,
    hostIndex               Integer32,
    hostInPkts              Counter32,
    hostOutPkts             Counter32,
    hostInOctets            Counter32,
    hostOutOctets           Counter32,
    hostOutErrors           Counter32,
    hostOutBroadcastPkts    Counter32,
    hostOutMulticastPkts    Counter32
}

hostAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The physical address of this host."
    ::= { hostEntry 1 }

hostCreationOrder OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that defines the relative ordering of
        the creation time of hosts captured for a
        particular hostControlEntry.  This index shall
        be between 1 and N, where N is the value of
        the associated hostControlTableSize.  The ordering
        of the indexes is based on the order of each entry's
        insertion into the table, in which entries added earlier
        have a lower index value than entries added later.

        It is important to note that the order for a
        particular entry may change as an (earlier) entry
        is deleted from the table.  Because this order may
        change, management stations should make use of the
        hostControlLastDeleteTime variable in the
        hostControlEntry associated with the relevant
        portion of the hostTable.  By observing
        this variable, the management station may detect
        the circumstances where a previous association
        between a value of hostCreationOrder
        and a hostEntry may no longer hold."
    ::= { hostEntry 2 }

hostIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The set of collected host statistics of which
        this entry is a part.  The set of hosts
        identified by a particular value of this
        index is associated with the hostControlEntry
        as identified by the same value of hostControlIndex."
    ::= { hostEntry 3 }

hostInPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets transmitted to this
        address since it was added to the hostTable."
    ::= { hostEntry 4 }

hostOutPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets, including bad packets, transmitted
        by this address since it was added to the hostTable."
    ::= { hostEntry 5 }

hostInOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of octets transmitted to this address since
        it was added to the hostTable (excluding framing
        bits but including FCS octets), except for those
        octets in bad packets."
    ::= { hostEntry 6 }

hostOutOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of octets transmitted by this address since
        it was added to the hostTable (excluding framing
        bits but including FCS octets), including those
        octets in bad packets."
    ::= { hostEntry 7 }

hostOutErrors OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of bad packets transmitted by this address
        since this host was added to the hostTable."
    ::= { hostEntry 8 }

hostOutBroadcastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets transmitted by this
        address that were directed to the broadcast address
        since this host was added to the hostTable."
    ::= { hostEntry 9 }

hostOutMulticastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets transmitted by this
        address that were directed to a multicast address
        since this host was added to the hostTable.
        Note that this number does not include packets
        directed to the broadcast address."
    ::= { hostEntry 10 }

-- host Time Table

hostTimeTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF HostTimeEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of time-ordered host table entries."
    ::= { hosts 3 }

hostTimeEntry OBJECT-TYPE
    SYNTAX     HostTimeEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A collection of statistics for a particular host that has
        been discovered on an interface of this device.  This
        collection includes the relative ordering of the creation
        time of this object.  For example, an instance of the
        hostTimeOutBroadcastPkts object might be named
        hostTimeOutBroadcastPkts.1.687"
    INDEX { hostTimeIndex, hostTimeCreationOrder }
    ::= { hostTimeTable 1 }

HostTimeEntry ::= SEQUENCE {
    hostTimeAddress              OCTET STRING,
    hostTimeCreationOrder        Integer32,
    hostTimeIndex                Integer32,
    hostTimeInPkts               Counter32,
    hostTimeOutPkts              Counter32,
    hostTimeInOctets             Counter32,
    hostTimeOutOctets            Counter32,
    hostTimeOutErrors            Counter32,
    hostTimeOutBroadcastPkts     Counter32,
    hostTimeOutMulticastPkts     Counter32
}

hostTimeAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The physical address of this host."
    ::= { hostTimeEntry 1 }

hostTimeCreationOrder OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in
        the hostTime table among those entries associated
        with the same hostControlEntry.  This index shall
        be between 1 and N, where N is the value of

        the associated hostControlTableSize.  The ordering
        of the indexes is based on the order of each entry's
        insertion into the table, in which entries added earlier
        have a lower index value than entries added later.
        Thus the management station has the ability to
        learn of new entries added to this table without
        downloading the entire table.

        It is important to note that the index for a
        particular entry may change as an (earlier) entry
        is deleted from the table.  Because this order may
        change, management stations should make use of the
        hostControlLastDeleteTime variable in the
        hostControlEntry associated with the relevant
        portion of the hostTimeTable.  By observing
        this variable, the management station may detect
        the circumstances where a download of the table
        may have missed entries, and where a previous
        association between a value of hostTimeCreationOrder
        and a hostTimeEntry may no longer hold."
    ::= { hostTimeEntry 2 }

hostTimeIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The set of collected host statistics of which
        this entry is a part.  The set of hosts
        identified by a particular value of this
        index is associated with the hostControlEntry
        as identified by the same value of hostControlIndex."
    ::= { hostTimeEntry 3 }

hostTimeInPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets transmitted to this
        address since it was added to the hostTimeTable."
    ::= { hostTimeEntry 4 }

hostTimeOutPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets, including bad packets, transmitted
        by this address since it was added to the hostTimeTable."
    ::= { hostTimeEntry 5 }

hostTimeInOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of octets transmitted to this address since
        it was added to the hostTimeTable (excluding framing
        bits but including FCS octets), except for those
        octets in bad packets."
    ::= { hostTimeEntry 6 }

hostTimeOutOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of octets transmitted by this address since
        it was added to the hostTimeTable (excluding framing
        bits but including FCS octets), including those
        octets in bad packets."
    ::= { hostTimeEntry 7 }

hostTimeOutErrors OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of bad packets transmitted by this address
        since this host was added to the hostTimeTable."
    ::= { hostTimeEntry 8 }

hostTimeOutBroadcastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets transmitted by this
        address that were directed to the broadcast address

        since this host was added to the hostTimeTable."
    ::= { hostTimeEntry 9 }

hostTimeOutMulticastPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of good packets transmitted by this
        address that were directed to a multicast address
        since this host was added to the hostTimeTable.
        Note that this number does not include packets directed
        to the broadcast address."
    ::= { hostTimeEntry 10 }

-- The Host Top "N" Group

-- Implementation of the Host Top N group is optional. The Host Top N
-- group requires the implementation of the host group.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Host Top N group is used to prepare reports that describe
-- the hosts that top a list ordered by one of their statistics.
-- The available statistics are samples of one of their
-- base statistics, over an interval specified by the management
-- station.  Thus, these statistics are rate based.  The management
-- station also selects how many such hosts are reported.

-- The hostTopNControlTable is used to initiate the generation of
-- such a report.  The management station may select the parameters
-- of such a report, such as which interface, which statistic,
-- how many hosts, and the start and stop times of the sampling.
-- When the report is prepared, entries are created in the
-- hostTopNTable associated with the relevant hostTopNControlEntry.
-- These entries are static for each report after it has been
-- prepared.

hostTopNControlTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF HostTopNControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of top N host control entries."
    ::= { hostTopN 1 }

hostTopNControlEntry OBJECT-TYPE
    SYNTAX     HostTopNControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of parameters that control the creation of a report
        of the top N hosts according to several metrics.  For
        example, an instance of the hostTopNDuration object might
        be named hostTopNDuration.3"
    INDEX { hostTopNControlIndex }
    ::= { hostTopNControlTable 1 }

HostTopNControlEntry ::= SEQUENCE {
    hostTopNControlIndex    Integer32,
    hostTopNHostIndex       Integer32,
    hostTopNRateBase        INTEGER,
    hostTopNTimeRemaining   Integer32,
    hostTopNDuration        Integer32,
    hostTopNRequestedSize   Integer32,
    hostTopNGrantedSize     Integer32,
    hostTopNStartTime       TimeTicks,
    hostTopNOwner           OwnerString,
    hostTopNStatus          EntryStatus
}

hostTopNControlIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry
        in the hostTopNControl table.  Each such
        entry defines one top N report prepared for
        one interface."
    ::= { hostTopNControlEntry 1 }

hostTopNHostIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The host table for which a top N report will be prepared
        on behalf of this entry.  The host table identified by a
        particular value of this index is associated with the same
        host table as identified by the same value of
        hostIndex.

        This object may not be modified if the associated
        hostTopNStatus object is equal to valid(1)."
    ::= { hostTopNControlEntry 2 }

hostTopNRateBase OBJECT-TYPE
    SYNTAX     INTEGER {
                 hostTopNInPkts(1),
                 hostTopNOutPkts(2),
                 hostTopNInOctets(3),
                 hostTopNOutOctets(4),
                 hostTopNOutErrors(5),
                 hostTopNOutBroadcastPkts(6),
                 hostTopNOutMulticastPkts(7)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The variable for each host that the hostTopNRate
        variable is based upon.

        This object may not be modified if the associated
        hostTopNStatus object is equal to valid(1)."
    ::= { hostTopNControlEntry 3 }

hostTopNTimeRemaining OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Seconds"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The number of seconds left in the report currently being
        collected.  When this object is modified by the management
        station, a new collection is started, possibly aborting
        a currently running report.  The new value is used
        as the requested duration of this report, which is
        loaded into the associated hostTopNDuration object.

        When this object is set to a non-zero value, any
        associated hostTopNEntries shall be made
        inaccessible by the monitor.  While the value of this
        object is non-zero, it decrements by one per second until
        it reaches zero.  During this time, all associated
        hostTopNEntries shall remain inaccessible.  At the time
        that this object decrements to zero, the report is made
        accessible in the hostTopNTable.  Thus, the hostTopN
        table needs to be created only at the end of the collection
        interval."
    DEFVAL { 0 }
    ::= { hostTopNControlEntry 4 }

hostTopNDuration OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Seconds"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of seconds that this report has collected
        during the last sampling interval, or if this
        report is currently being collected, the number
        of seconds that this report is being collected
        during this sampling interval.

        When the associated hostTopNTimeRemaining object is set,
        this object shall be set by the probe to the same value
        and shall not be modified until the next time
        the hostTopNTimeRemaining is set.

        This value shall be zero if no reports have been
        requested for this hostTopNControlEntry."
    DEFVAL { 0 }
    ::= { hostTopNControlEntry 5 }

hostTopNRequestedSize OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The maximum number of hosts requested for the top N
        table.

        When this object is created or modified, the probe
        should set hostTopNGrantedSize as closely to this
        object as is possible for the particular probe
        implementation and available resources."
    DEFVAL { 10 }
    ::= { hostTopNControlEntry 6 }

hostTopNGrantedSize OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The maximum number of hosts in the top N table.

        When the associated hostTopNRequestedSize object is
        created or modified, the probe should set this
        object as closely to the requested value as is possible
        for the particular implementation and available

        resources. The probe must not lower this value except
        as a result of a set to the associated
        hostTopNRequestedSize object.

        Hosts with the highest value of hostTopNRate shall be
        placed in this table in decreasing order of this rate
        until there is no more room or until there are no more
        hosts."
    ::= { hostTopNControlEntry 7 }

hostTopNStartTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime when this top N report was
        last started.  In other words, this is the time that
        the associated hostTopNTimeRemaining object was
        modified to start the requested report."
    ::= { hostTopNControlEntry 8 }

hostTopNOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { hostTopNControlEntry 9 }

hostTopNStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this hostTopNControl entry.

        If this object is not equal to valid(1), all associated
        hostTopNEntries shall be deleted by the agent."
    ::= { hostTopNControlEntry 10 }

hostTopNTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF HostTopNEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of top N host entries."
    ::= { hostTopN 2 }

hostTopNEntry OBJECT-TYPE
    SYNTAX     HostTopNEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of statistics for a host that is part of a top N
        report.  For example, an instance of the hostTopNRate
        object might be named hostTopNRate.3.10"
    INDEX { hostTopNReport, hostTopNIndex }
    ::= { hostTopNTable 1 }

HostTopNEntry ::= SEQUENCE {
    hostTopNReport                Integer32,
    hostTopNIndex                 Integer32,
    hostTopNAddress               OCTET STRING,
    hostTopNRate                  Integer32
}

hostTopNReport OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "This object identifies the top N report of which
        this entry is a part.  The set of hosts
        identified by a particular value of this
        object is part of the same report as identified
        by the same value of the hostTopNControlIndex object."
    ::= { hostTopNEntry 1 }

hostTopNIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in
        the hostTopN table among those in the same report.
        This index is between 1 and N, where N is the
        number of entries in this table.  Increasing values
        of hostTopNIndex shall be assigned to entries with
        decreasing values of hostTopNRate until index N
        is assigned to the entry with the lowest value of
        hostTopNRate or there are no more hostTopNEntries."
    ::= { hostTopNEntry 2 }

hostTopNAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The physical address of this host."
    ::= { hostTopNEntry 3 }

hostTopNRate OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The amount of change in the selected variable
        during this sampling interval.  The selected
        variable is this host's instance of the object
        selected by hostTopNRateBase."
    ::= { hostTopNEntry 4 }

-- The Matrix Group

-- Implementation of the Matrix group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Matrix group consists of the matrixControlTable, matrixSDTable
-- and the matrixDSTable.  These tables store statistics for a
-- particular conversation between two addresses.  As the device
-- detects a new conversation, including those to a non-unicast
-- address, it creates a new entry in both of the matrix tables.
-- It must only create new entries based on information
-- received in good packets.  If the monitoring device finds
-- itself short of resources, it may delete entries as needed.
-- It is suggested that the device delete the least recently used
-- entries first.

matrixControlTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF MatrixControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of information entries for the
        traffic matrix on each interface."
    ::= { matrix 1 }

matrixControlEntry OBJECT-TYPE
    SYNTAX     MatrixControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Information about a traffic matrix on a particular

        interface.  For example, an instance of the
        matrixControlLastDeleteTime object might be named
        matrixControlLastDeleteTime.1"
    INDEX { matrixControlIndex }
    ::= { matrixControlTable 1 }

MatrixControlEntry ::= SEQUENCE {
    matrixControlIndex           Integer32,
    matrixControlDataSource      OBJECT IDENTIFIER,
    matrixControlTableSize       Integer32,
    matrixControlLastDeleteTime  TimeTicks,
    matrixControlOwner           OwnerString,
    matrixControlStatus          EntryStatus
}

matrixControlIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in the
        matrixControl table.  Each such entry defines
        a function that discovers conversations on a particular
        interface and places statistics about them in the
        matrixSDTable and the matrixDSTable on behalf of this
        matrixControlEntry."
    ::= { matrixControlEntry 1 }

matrixControlDataSource OBJECT-TYPE
    SYNTAX     OBJECT IDENTIFIER
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object identifies the source of
        the data from which this entry creates a traffic matrix.
        This source can be any interface on this device.  In
        order to identify a particular interface, this object
        shall identify the instance of the ifIndex object,
        defined in RFC 2233 [17], for the desired
        interface.  For example, if an entry were to receive data
        from interface #1, this object would be set to ifIndex.1.

        The statistics in this group reflect all packets
        on the local network segment attached to the identified
        interface.

        An agent may or may not be able to tell if fundamental
        changes to the media of the interface have occurred and

        necessitate an invalidation of this entry.  For example, a
        hot-pluggable ethernet card could be pulled out and replaced
        by a token-ring card.  In such a case, if the agent has such
        knowledge of the change, it is recommended that it
        invalidate this entry.

        This object may not be modified if the associated
        matrixControlStatus object is equal to valid(1)."
    ::= { matrixControlEntry 2 }

matrixControlTableSize OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of matrixSDEntries in the matrixSDTable
        for this interface.  This must also be the value of
        the number of entries in the matrixDSTable for this
        interface."
    ::= { matrixControlEntry 3 }

matrixControlLastDeleteTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime when the last entry
        was deleted from the portion of the matrixSDTable
        or matrixDSTable associated with this matrixControlEntry.
        If no deletions have occurred, this value shall be
        zero."
    ::= { matrixControlEntry 4 }

matrixControlOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { matrixControlEntry 5 }

matrixControlStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this matrixControl entry.

        If this object is not equal to valid(1), all associated
        entries in the matrixSDTable and the matrixDSTable
        shall be deleted by the agent."
    ::= { matrixControlEntry 6 }

matrixSDTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF MatrixSDEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of traffic matrix entries indexed by
        source and destination MAC address."
    ::= { matrix 2 }

matrixSDEntry OBJECT-TYPE
    SYNTAX     MatrixSDEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A collection of statistics for communications between
        two addresses on a particular interface.  For example,
        an instance of the matrixSDPkts object might be named
        matrixSDPkts.1.6.8.0.32.27.3.176.6.8.0.32.10.8.113"
    INDEX { matrixSDIndex,
            matrixSDSourceAddress, matrixSDDestAddress }
    ::= { matrixSDTable 1 }

MatrixSDEntry ::= SEQUENCE {
    matrixSDSourceAddress       OCTET STRING,
    matrixSDDestAddress         OCTET STRING,
    matrixSDIndex               Integer32,
    matrixSDPkts                Counter32,
    matrixSDOctets              Counter32,
    matrixSDErrors              Counter32
}

matrixSDSourceAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The source physical address."
    ::= { matrixSDEntry 1 }

matrixSDDestAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The destination physical address."
    ::= { matrixSDEntry 2 }

matrixSDIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The set of collected matrix statistics of which
        this entry is a part.  The set of matrix statistics
        identified by a particular value of this index
        is associated with the same matrixControlEntry
        as identified by the same value of matrixControlIndex."
    ::= { matrixSDEntry 3 }

matrixSDPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets transmitted from the source
        address to the destination address (this number includes
        bad packets)."
    ::= { matrixSDEntry 4 }

matrixSDOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of octets (excluding framing bits but
        including FCS octets) contained in all packets
        transmitted from the source address to the
        destination address."
    ::= { matrixSDEntry 5 }

matrixSDErrors OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of bad packets transmitted from
        the source address to the destination address."
    ::= { matrixSDEntry 6 }

-- Traffic matrix tables from destination to source

matrixDSTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF MatrixDSEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of traffic matrix entries indexed by
        destination and source MAC address."
    ::= { matrix 3 }

matrixDSEntry OBJECT-TYPE
    SYNTAX     MatrixDSEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A collection of statistics for communications between
        two addresses on a particular interface.  For example,
        an instance of the matrixSDPkts object might be named
        matrixSDPkts.1.6.8.0.32.10.8.113.6.8.0.32.27.3.176"
    INDEX { matrixDSIndex,
            matrixDSDestAddress, matrixDSSourceAddress }
    ::= { matrixDSTable 1 }

MatrixDSEntry ::= SEQUENCE {
    matrixDSSourceAddress       OCTET STRING,
    matrixDSDestAddress         OCTET STRING,
    matrixDSIndex               Integer32,
    matrixDSPkts                Counter32,
    matrixDSOctets              Counter32,
    matrixDSErrors              Counter32
}

matrixDSSourceAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The source physical address."
    ::= { matrixDSEntry 1 }

matrixDSDestAddress OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The destination physical address."
    ::= { matrixDSEntry 2 }

matrixDSIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The set of collected matrix statistics of which
        this entry is a part.  The set of matrix statistics
        identified by a particular value of this index
        is associated with the same matrixControlEntry
        as identified by the same value of matrixControlIndex."
    ::= { matrixDSEntry 3 }

matrixDSPkts OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets transmitted from the source
        address to the destination address (this number includes
        bad packets)."
    ::= { matrixDSEntry 4 }

matrixDSOctets OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of octets (excluding framing bits
        but including FCS octets) contained in all packets
        transmitted from the source address to the
        destination address."
    ::= { matrixDSEntry 5 }

matrixDSErrors OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of bad packets transmitted from
        the source address to the destination address."
    ::= { matrixDSEntry 6 }

-- The Filter Group

-- Implementation of the Filter group is optional.

-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Filter group allows packets to be captured with an
-- arbitrary filter expression.  A logical data and
-- event stream or "channel" is formed by the packets
-- that match the filter expression.
--
-- This filter mechanism allows the creation of an arbitrary
-- logical expression with which to filter packets.  Each
-- filter associated with a channel is OR'ed with the others.
-- Within a filter, any bits checked in the data and status are
-- AND'ed with respect to other bits in the same filter.  The
-- NotMask also allows for checking for inequality.  Finally,
-- the channelAcceptType object allows for inversion of the
-- whole equation.
--
-- If a management station wishes to receive a trap to alert it
-- that new packets have been captured and are available for
-- download, it is recommended that it set up an alarm entry that
-- monitors the value of the relevant channelMatches instance.
--
-- The channel can be turned on or off, and can also
-- generate events when packets pass through it.

filterTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF FilterEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of packet filter entries."
    ::= { filter 1 }

filterEntry OBJECT-TYPE
    SYNTAX     FilterEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of parameters for a packet filter applied on a
        particular interface.  As an example, an instance of the
        filterPktData object might be named filterPktData.12"
    INDEX { filterIndex }
    ::= { filterTable 1 }

FilterEntry ::= SEQUENCE {
    filterIndex                 Integer32,
    filterChannelIndex          Integer32,
    filterPktDataOffset         Integer32,
    filterPktData               OCTET STRING,
    filterPktDataMask           OCTET STRING,
    filterPktDataNotMask        OCTET STRING,
    filterPktStatus             Integer32,
    filterPktStatusMask         Integer32,
    filterPktStatusNotMask      Integer32,
    filterOwner                 OwnerString,
    filterStatus                EntryStatus
}

filterIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry
        in the filter table.  Each such entry defines
        one filter that is to be applied to every packet
        received on an interface."
    ::= { filterEntry 1 }

filterChannelIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object identifies the channel of which this filter
        is a part.  The filters identified by a particular value
        of this object are associated with the same channel as
        identified by the same value of the channelIndex object."
    ::= { filterEntry 2 }

filterPktDataOffset OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The offset from the beginning of each packet where
        a match of packet data will be attempted.  This offset
        is measured from the point in the physical layer
        packet after the framing bits, if any.  For example,
        in an Ethernet frame, this point is at the beginning of
        the destination MAC address.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    DEFVAL { 0 }
    ::= { filterEntry 3 }

filterPktData OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The data that is to be matched with the input packet.
        For each packet received, this filter and the accompanying
        filterPktDataMask and filterPktDataNotMask will be
        adjusted for the offset.  The only bits relevant to this
        match algorithm are those that have the corresponding
        filterPktDataMask bit equal to one.  The following three
        rules are then applied to every packet:

        (1) If the packet is too short and does not have data
            corresponding to part of the filterPktData, the packet
            will fail this data match.

        (2) For each relevant bit from the packet with the
            corresponding filterPktDataNotMask bit set to zero, if
            the bit from the packet is not equal to the corresponding
            bit from the filterPktData, then the packet will fail
            this data match.

        (3) If for every relevant bit from the packet with the
            corresponding filterPktDataNotMask bit set to one, the
            bit from the packet is equal to the corresponding bit
            from the filterPktData, then the packet will fail this
            data match.

        Any packets that have not failed any of the three matches
        above have passed this data match.  In particular, a zero
        length filter will match any packet.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    ::= { filterEntry 4 }

filterPktDataMask OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The mask that is applied to the match process.
        After adjusting this mask for the offset, only those
        bits in the received packet that correspond to bits set
        in this mask are relevant for further processing by the

        match algorithm.  The offset is applied to filterPktDataMask
        in the same way it is applied to the filter.  For the
        purposes of the matching algorithm, if the associated
        filterPktData object is longer than this mask, this mask is
        conceptually extended with '1' bits until it reaches the
        length of the filterPktData object.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    ::= { filterEntry 5 }

filterPktDataNotMask OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The inversion mask that is applied to the match
        process.  After adjusting this mask for the offset,
        those relevant bits in the received packet that correspond
        to bits cleared in this mask must all be equal to their
        corresponding bits in the filterPktData object for the packet
        to be accepted.  In addition, at least one of those relevant
        bits in the received packet that correspond to bits set in
        this mask must be different to its corresponding bit in the
        filterPktData object.

        For the purposes of the matching algorithm, if the associated
        filterPktData object is longer than this mask, this mask is
        conceptually extended with '0' bits until it reaches the
        length of the filterPktData object.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    ::= { filterEntry 6 }

filterPktStatus OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status that is to be matched with the input packet.
        The only bits relevant to this match algorithm are those that
        have the corresponding filterPktStatusMask bit equal to one.
        The following two rules are then applied to every packet:

        (1) For each relevant bit from the packet status with the
            corresponding filterPktStatusNotMask bit set to zero, if
            the bit from the packet status is not equal to the

            corresponding bit from the filterPktStatus, then the
            packet will fail this status match.

        (2) If for every relevant bit from the packet status with the
            corresponding filterPktStatusNotMask bit set to one, the
            bit from the packet status is equal to the corresponding
            bit from the filterPktStatus, then the packet will fail
            this status match.

        Any packets that have not failed either of the two matches
        above have passed this status match.  In particular, a zero
        length status filter will match any packet's status.

        The value of the packet status is a sum.  This sum
        initially takes the value zero.  Then, for each
        error, E, that has been discovered in this packet,
        2 raised to a value representing E is added to the sum.
        The errors and the bits that represent them are dependent
        on the media type of the interface that this channel
        is receiving packets from.

        The errors defined for a packet captured off of an
        Ethernet interface are as follows:

            bit #    Error
                0    Packet is longer than 1518 octets
                1    Packet is shorter than 64 octets
                2    Packet experienced a CRC or Alignment error

        For example, an Ethernet fragment would have a
        value of 6 (2^1 + 2^2).

        As this MIB is expanded to new media types, this object
        will have other media-specific errors defined.

        For the purposes of this status matching algorithm, if the
        packet status is longer than this filterPktStatus object,
        this object is conceptually extended with '0' bits until it
        reaches the size of the packet status.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    ::= { filterEntry 7 }

filterPktStatusMask OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The mask that is applied to the status match process.
        Only those bits in the received packet that correspond to
        bits set in this mask are relevant for further processing
        by the status match algorithm.  For the purposes
        of the matching algorithm, if the associated filterPktStatus
        object is longer than this mask, this mask is conceptually
        extended with '1' bits until it reaches the size of the
        filterPktStatus.  In addition, if a packet status is longer
        than this mask, this mask is conceptually extended with '0'
        bits until it reaches the size of the packet status.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    ::= { filterEntry 8 }

filterPktStatusNotMask OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The inversion mask that is applied to the status match
        process.  Those relevant bits in the received packet status
        that correspond to bits cleared in this mask must all be
        equal to their corresponding bits in the filterPktStatus
        object for the packet to be accepted.  In addition, at least
        one of those relevant bits in the received packet status
        that correspond to bits set in this mask must be different
        to its corresponding bit in the filterPktStatus object for
        the packet to be accepted.

        For the purposes of the matching algorithm, if the associated
        filterPktStatus object or a packet status is longer than this
        mask, this mask is conceptually extended with '0' bits until
        it reaches the longer of the lengths of the filterPktStatus
        object and the packet status.

        This object may not be modified if the associated
        filterStatus object is equal to valid(1)."
    ::= { filterEntry 9 }

filterOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { filterEntry 10 }

filterStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this filter entry."
    ::= { filterEntry 11 }

channelTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF ChannelEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of packet channel entries."
    ::= { filter 2 }

channelEntry OBJECT-TYPE
    SYNTAX     ChannelEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of parameters for a packet channel applied on a
        particular interface.  As an example, an instance of the
        channelMatches object might be named channelMatches.3"
    INDEX { channelIndex }
    ::= { channelTable 1 }

ChannelEntry ::= SEQUENCE {
    channelIndex                 Integer32,
    channelIfIndex               Integer32,
    channelAcceptType            INTEGER,
    channelDataControl           INTEGER,
    channelTurnOnEventIndex      Integer32,
    channelTurnOffEventIndex     Integer32,
    channelEventIndex            Integer32,
    channelEventStatus           INTEGER,
    channelMatches               Counter32,
    channelDescription           DisplayString,
    channelOwner                 OwnerString,
    channelStatus                EntryStatus
}

channelIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in the channel
        table.  Each such entry defines one channel, a logical
        data and event stream.

        It is suggested that before creating a channel, an
        application should scan all instances of the
        filterChannelIndex object to make sure that there are no
        pre-existing filters that would be inadvertently be linked
        to the channel."
    ::= { channelEntry 1 }

channelIfIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The value of this object uniquely identifies the
        interface on this remote network monitoring device to which
        the associated filters are applied to allow data into this
        channel.  The interface identified by a particular value
        of this object is the same interface as identified by the
        same value of the ifIndex object, defined in RFC 2233 [17].

        The filters in this group are applied to all packets on
        the local network segment attached to the identified
        interface.

        An agent may or may not be able to tell if fundamental
        changes to the media of the interface have occurred and
        necessitate an invalidation of this entry.  For example, a
        hot-pluggable ethernet card could be pulled out and replaced
        by a token-ring card.  In such a case, if the agent has such
        knowledge of the change, it is recommended that it
        invalidate this entry.

        This object may not be modified if the associated
        channelStatus object is equal to valid(1)."
    ::= { channelEntry 2 }

channelAcceptType OBJECT-TYPE
    SYNTAX     INTEGER {
                 acceptMatched(1),
                 acceptFailed(2)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object controls the action of the filters
        associated with this channel.  If this object is equal
        to acceptMatched(1), packets will be accepted to this
        channel if they are accepted by both the packet data and
        packet status matches of an associated filter.  If
        this object is equal to acceptFailed(2), packets will
        be accepted to this channel only if they fail either
        the packet data match or the packet status match of
        each of the associated filters.

        In particular, a channel with no associated filters will
        match no packets if set to acceptMatched(1) case and will
        match all packets in the acceptFailed(2) case.

        This object may not be modified if the associated
        channelStatus object is equal to valid(1)."
    ::= { channelEntry 3 }

channelDataControl OBJECT-TYPE
    SYNTAX     INTEGER {
                 on(1),
                 off(2)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "This object controls the flow of data through this channel.
        If this object is on(1), data, status and events flow
        through this channel.  If this object is off(2), data,
        status and events will not flow through this channel."
    DEFVAL { off }
    ::= { channelEntry 4 }

channelTurnOnEventIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The value of this object identifies the event
        that is configured to turn the associated
        channelDataControl from off to on when the event is
        generated.  The event identified by a particular value
        of this object is the same event as identified by the
        same value of the eventIndex object.  If there is no
        corresponding entry in the eventTable, then no
        association exists.  In fact, if no event is intended
        for this channel, channelTurnOnEventIndex must be
        set to zero, a non-existent event index.

        This object may not be modified if the associated
        channelStatus object is equal to valid(1)."
    ::= { channelEntry 5 }

channelTurnOffEventIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The value of this object identifies the event
        that is configured to turn the associated
        channelDataControl from on to off when the event is
        generated.  The event identified by a particular value
        of this object is the same event as identified by the
        same value of the eventIndex object.  If there is no
        corresponding entry in the eventTable, then no
        association exists.  In fact, if no event is intended
        for this channel, channelTurnOffEventIndex must be
        set to zero, a non-existent event index.

        This object may not be modified if the associated
        channelStatus object is equal to valid(1)."
    ::= { channelEntry 6 }

channelEventIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The value of this object identifies the event
        that is configured to be generated when the
        associated channelDataControl is on and a packet
        is matched.  The event identified by a particular value
        of this object is the same event as identified by the
        same value of the eventIndex object.  If there is no
        corresponding entry in the eventTable, then no
        association exists.  In fact, if no event is intended
        for this channel, channelEventIndex must be
        set to zero, a non-existent event index.

        This object may not be modified if the associated
        channelStatus object is equal to valid(1)."
    ::= { channelEntry 7 }

channelEventStatus OBJECT-TYPE
    SYNTAX     INTEGER {
                 eventReady(1),
                 eventFired(2),
                 eventAlwaysReady(3)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The event status of this channel.

        If this channel is configured to generate events
        when packets are matched, a means of controlling
        the flow of those events is often needed.  When
        this object is equal to eventReady(1), a single
        event may be generated, after which this object
        will be set by the probe to eventFired(2).  While
        in the eventFired(2) state, no events will be
        generated until the object is modified to
        eventReady(1) (or eventAlwaysReady(3)).  The
        management station can thus easily respond to a
        notification of an event by re-enabling this object.

        If the management station wishes to disable this
        flow control and allow events to be generated
        at will, this object may be set to
        eventAlwaysReady(3).  Disabling the flow control
        is discouraged as it can result in high network
        traffic or other performance problems."
    DEFVAL { eventReady }
    ::= { channelEntry 8 }

channelMatches OBJECT-TYPE
    SYNTAX     Counter32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of times this channel has matched a packet.
        Note that this object is updated even when
        channelDataControl is set to off."
    ::= { channelEntry 9 }

channelDescription OBJECT-TYPE
    SYNTAX     DisplayString (SIZE (0..127))
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "A comment describing this channel."
    ::= { channelEntry 10 }

channelOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { channelEntry 11 }

channelStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this channel entry."
    ::= { channelEntry 12 }

-- The Packet Capture Group

-- Implementation of the Packet Capture group is optional. The Packet
-- Capture Group requires implementation of the Filter Group.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Packet Capture group allows packets to be captured
-- upon a filter match.  The bufferControlTable controls
-- the captured packets output from a channel that is
-- associated with it.  The captured packets are placed
-- in entries in the captureBufferTable.  These entries are
-- associated with the bufferControlEntry on whose behalf they
-- were stored.

bufferControlTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF BufferControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of buffers control entries."
    ::= { capture 1 }

bufferControlEntry OBJECT-TYPE
    SYNTAX     BufferControlEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of parameters that control the collection of a stream
        of packets that have matched filters.  As an example, an
        instance of the bufferControlCaptureSliceSize object might
        be named bufferControlCaptureSliceSize.3"
    INDEX { bufferControlIndex }
    ::= { bufferControlTable 1 }

BufferControlEntry ::= SEQUENCE {
    bufferControlIndex                Integer32,
    bufferControlChannelIndex         Integer32,
    bufferControlFullStatus           INTEGER,
    bufferControlFullAction           INTEGER,
    bufferControlCaptureSliceSize     Integer32,
    bufferControlDownloadSliceSize    Integer32,
    bufferControlDownloadOffset       Integer32,
    bufferControlMaxOctetsRequested   Integer32,
    bufferControlMaxOctetsGranted     Integer32,
    bufferControlCapturedPackets      Integer32,
    bufferControlTurnOnTime           TimeTicks,
    bufferControlOwner                OwnerString,
    bufferControlStatus               EntryStatus
}

bufferControlIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry
        in the bufferControl table.  The value of this
        index shall never be zero.  Each such
        entry defines one set of packets that is
        captured and controlled by one or more filters."
    ::= { bufferControlEntry 1 }

bufferControlChannelIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "An index that identifies the channel that is the
        source of packets for this bufferControl table.
        The channel identified by a particular value of this
        index is the same as identified by the same value of
        the channelIndex object.

        This object may not be modified if the associated
        bufferControlStatus object is equal to valid(1)."
    ::= { bufferControlEntry 2 }

bufferControlFullStatus OBJECT-TYPE
    SYNTAX     INTEGER {

                 spaceAvailable(1),
                 full(2)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "This object shows whether the buffer has room to
        accept new packets or if it is full.

        If the status is spaceAvailable(1), the buffer is
        accepting new packets normally.  If the status is
        full(2) and the associated bufferControlFullAction
        object is wrapWhenFull, the buffer is accepting new
        packets by deleting enough of the oldest packets
        to make room for new ones as they arrive.  Otherwise,
        if the status is full(2) and the
        bufferControlFullAction object is lockWhenFull,
        then the buffer has stopped collecting packets.

        When this object is set to full(2) the probe must
        not later set it to spaceAvailable(1) except in the
        case of a significant gain in resources such as
        an increase of bufferControlOctetsGranted.  In
        particular, the wrap-mode action of deleting old
        packets to make room for newly arrived packets
        must not affect the value of this object."
    ::= { bufferControlEntry 3 }

bufferControlFullAction OBJECT-TYPE
    SYNTAX     INTEGER {
                 lockWhenFull(1),
                 wrapWhenFull(2)    -- FIFO
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "Controls the action of the buffer when it
        reaches the full status.  When in the lockWhenFull(1)
        state and a packet is added to the buffer that
        fills the buffer, the bufferControlFullStatus will
        be set to full(2) and this buffer will stop capturing
        packets."
    ::= { bufferControlEntry 4 }

bufferControlCaptureSliceSize OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The maximum number of octets of each packet
        that will be saved in this capture buffer.
        For example, if a 1500 octet packet is received by
        the probe and this object is set to 500, then only
        500 octets of the packet will be stored in the
        associated capture buffer.  If this variable is set
        to 0, the capture buffer will save as many octets
        as is possible.

        This object may not be modified if the associated
        bufferControlStatus object is equal to valid(1)."
    DEFVAL { 100 }
    ::= { bufferControlEntry 5 }

bufferControlDownloadSliceSize OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The maximum number of octets of each packet
        in this capture buffer that will be returned in
        an SNMP retrieval of that packet.  For example,
        if 500 octets of a packet have been stored in the
        associated capture buffer, the associated
        bufferControlDownloadOffset is 0, and this
        object is set to 100, then the captureBufferPacket
        object that contains the packet will contain only
        the first 100 octets of the packet.

        A prudent manager will take into account possible
        interoperability or fragmentation problems that may
        occur if the download slice size is set too large.
        In particular, conformant SNMP implementations are not
        required to accept messages whose length exceeds 484
        octets, although they are encouraged to support larger
        datagrams whenever feasible."
    DEFVAL { 100 }
    ::= { bufferControlEntry 6 }

bufferControlDownloadOffset OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The offset of the first octet of each packet
        in this capture buffer that will be returned in
        an SNMP retrieval of that packet.  For example,
        if 500 octets of a packet have been stored in the
        associated capture buffer and this object is set to
        100, then the captureBufferPacket object that
        contains the packet will contain bytes starting
        100 octets into the packet."
    DEFVAL { 0 }
    ::= { bufferControlEntry 7 }

bufferControlMaxOctetsRequested OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The requested maximum number of octets to be
        saved in this captureBuffer, including any
        implementation-specific overhead. If this variable
        is set to -1, the capture buffer will save as many
        octets as is possible.

        When this object is created or modified, the probe
        should set bufferControlMaxOctetsGranted as closely
        to this object as is possible for the particular probe
        implementation and available resources.  However, if
        the object has the special value of -1, the probe
        must set bufferControlMaxOctetsGranted to -1."
    DEFVAL { -1 }
    ::= { bufferControlEntry 8 }

bufferControlMaxOctetsGranted OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The maximum number of octets that can be
        saved in this captureBuffer, including overhead.
        If this variable is -1, the capture buffer will save
        as many octets as possible.

        When the bufferControlMaxOctetsRequested object is
        created or modified, the probe should set this object
        as closely to the requested value as is possible for the
        particular probe implementation and available resources.
        However, if the request object has the special value

        of -1, the probe must set this object to -1.

        The probe must not lower this value except as a result of
        a modification to the associated
        bufferControlMaxOctetsRequested object.

        When this maximum number of octets is reached
        and a new packet is to be added to this
        capture buffer and the corresponding
        bufferControlFullAction is set to wrapWhenFull(2),
        enough of the oldest packets associated with this
        capture buffer shall be deleted by the agent so
        that the new packet can be added.  If the corresponding
        bufferControlFullAction is set to lockWhenFull(1),
        the new packet shall be discarded.  In either case,
        the probe must set bufferControlFullStatus to
        full(2).

        When the value of this object changes to a value less
        than the current value, entries are deleted from
        the captureBufferTable associated with this
        bufferControlEntry.  Enough of the
        oldest of these captureBufferEntries shall be
        deleted by the agent so that the number of octets
        used remains less than or equal to the new value of
        this object.

        When the value of this object changes to a value greater
        than the current value, the number of associated
        captureBufferEntries may be allowed to grow."
    ::= { bufferControlEntry 9 }

bufferControlCapturedPackets OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Packets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of packets currently in this captureBuffer."
    ::= { bufferControlEntry 10 }

bufferControlTurnOnTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime when this capture buffer was
        first turned on."
    ::= { bufferControlEntry 11 }

bufferControlOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it."
    ::= { bufferControlEntry 12 }

bufferControlStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this buffer Control Entry."
    ::= { bufferControlEntry 13 }

captureBufferTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF CaptureBufferEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of packets captured off of a channel."
    ::= { capture 2 }

captureBufferEntry OBJECT-TYPE
    SYNTAX     CaptureBufferEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A packet captured off of an attached network.  As an
        example, an instance of the captureBufferPacketData
        object might be named captureBufferPacketData.3.1783"
    INDEX { captureBufferControlIndex, captureBufferIndex }
    ::= { captureBufferTable 1 }

CaptureBufferEntry ::= SEQUENCE {
    captureBufferControlIndex   Integer32,
    captureBufferIndex          Integer32,
    captureBufferPacketID       Integer32,
    captureBufferPacketData     OCTET STRING,
    captureBufferPacketLength   Integer32,
    captureBufferPacketTime     Integer32,
    captureBufferPacketStatus   Integer32
}

captureBufferControlIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The index of the bufferControlEntry with which
        this packet is associated."
    ::= { captureBufferEntry 1 }

captureBufferIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..2147483647)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry
        in the captureBuffer table associated with a
        particular bufferControlEntry.  This index will
        start at 1 and increase by one for each new packet
        added with the same captureBufferControlIndex.

        Should this value reach 2147483647, the next packet
        added with the same captureBufferControlIndex shall
        cause this value to wrap around to 1."
    ::= { captureBufferEntry 2 }

captureBufferPacketID OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that describes the order of packets
        that are received on a particular interface.
        The packetID of a packet captured on an
        interface is defined to be greater than the
        packetID's of all packets captured previously on
        the same interface.  As the captureBufferPacketID
        object has a maximum positive value of 2^31 - 1,
        any captureBufferPacketID object shall have the
        value of the associated packet's packetID mod 2^31."
    ::= { captureBufferEntry 3 }

captureBufferPacketData OBJECT-TYPE
    SYNTAX     OCTET STRING
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The data inside the packet, starting at the beginning
        of the packet plus any offset specified in the

        associated bufferControlDownloadOffset, including any
        link level headers.  The length of the data in this object
        is the minimum of the length of the captured packet minus
        the offset, the length of the associated
        bufferControlCaptureSliceSize minus the offset, and the
        associated bufferControlDownloadSliceSize.  If this minimum
        is less than zero, this object shall have a length of zero."
    ::= { captureBufferEntry 4 }

captureBufferPacketLength OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Octets"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The actual length (off the wire) of the packet stored
        in this entry, including FCS octets."
    ::= { captureBufferEntry 5 }

captureBufferPacketTime OBJECT-TYPE
    SYNTAX     Integer32
    UNITS      "Milliseconds"
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of milliseconds that had passed since
        this capture buffer was first turned on when this
        packet was captured."
    ::= { captureBufferEntry 6 }

captureBufferPacketStatus OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "A value which indicates the error status of this packet.

        The value of this object is defined in the same way as
        filterPktStatus.  The value is a sum.  This sum
        initially takes the value zero.  Then, for each
        error, E, that has been discovered in this packet,
        2 raised to a value representing E is added to the sum.

        The errors defined for a packet captured off of an
        Ethernet interface are as follows:

            bit #    Error
                0    Packet is longer than 1518 octets

                1    Packet is shorter than 64 octets
                2    Packet experienced a CRC or Alignment error
                3    First packet in this capture buffer after
                     it was detected that some packets were
                     not processed correctly.
                4    Packet's order in buffer is only approximate
                     (May only be set for packets sent from
                     the probe)

        For example, an Ethernet fragment would have a
        value of 6 (2^1 + 2^2).

        As this MIB is expanded to new media types, this object
        will have other media-specific errors defined."
    ::= { captureBufferEntry 7 }

-- The Event Group

-- Implementation of the Event group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Event group controls the generation and notification
-- of events from this device.  Each entry in the eventTable
-- describes the parameters of the event that can be triggered.
-- Each event entry is fired by an associated condition located
-- elsewhere in the MIB.  An event entry may also be associated
-- with a function elsewhere in the MIB that will be executed
-- when the event is generated.  For example, a channel may
-- be turned on or off by the firing of an event.
--
-- Each eventEntry may optionally specify that a log entry
-- be created on its behalf whenever the event occurs.
-- Each entry may also specify that notification should
-- occur by way of SNMP trap messages.  In this case, the
-- community for the trap message is given in the associated
-- eventCommunity object.  The enterprise and specific trap
-- fields of the trap are determined by the condition that
-- triggered the event.  Two traps are defined: risingAlarm and
-- fallingAlarm.  If the eventTable is triggered by a condition
-- specified elsewhere, the enterprise and specific trap fields
-- must be specified for traps generated for that condition.

eventTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF EventEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of events to be generated."
    ::= { event 1 }

eventEntry OBJECT-TYPE
    SYNTAX     EventEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of parameters that describe an event to be generated
        when certain conditions are met.  As an example, an instance
        of the eventLastTimeSent object might be named
        eventLastTimeSent.6"
    INDEX { eventIndex }
    ::= { eventTable 1 }

EventEntry ::= SEQUENCE {
    eventIndex          Integer32,
    eventDescription    DisplayString,
    eventType           INTEGER,
    eventCommunity      OCTET STRING,
    eventLastTimeSent   TimeTicks,
    eventOwner          OwnerString,
    eventStatus         EntryStatus
}

eventIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry in the
        event table.  Each such entry defines one event that
        is to be generated when the appropriate conditions
        occur."
    ::= { eventEntry 1 }

eventDescription OBJECT-TYPE
    SYNTAX     DisplayString (SIZE (0..127))
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "A comment describing this event entry."
    ::= { eventEntry 2 }

eventType OBJECT-TYPE
    SYNTAX     INTEGER {
                 none(1),
                 log(2),
                 snmptrap(3),    -- send an SNMP trap
                 logandtrap(4)
               }
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The type of notification that the probe will make
        about this event.  In the case of log, an entry is
        made in the log table for each event.  In the case of
        snmp-trap, an SNMP trap is sent to one or more
        management stations."
    ::= { eventEntry 3 }

eventCommunity OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE (0..127))
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "If an SNMP trap is to be sent, it will be sent to
        the SNMP community specified by this octet string."
    ::= { eventEntry 4 }

eventLastTimeSent OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime at the time this event
        entry last generated an event.  If this entry has
        not generated any events, this value will be
        zero."
    ::= { eventEntry 5 }

eventOwner OBJECT-TYPE
    SYNTAX     OwnerString
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The entity that configured this entry and is therefore
        using the resources assigned to it.

        If this object contains a string starting with 'monitor'
        and has associated entries in the log table, all connected
        management stations should retrieve those log entries,
        as they may have significance to all management stations
        connected to this device"
    ::= { eventEntry 6 }

eventStatus OBJECT-TYPE
    SYNTAX     EntryStatus
    MAX-ACCESS read-create
    STATUS     current
    DESCRIPTION
        "The status of this event entry.

        If this object is not equal to valid(1), all associated
        log entries shall be deleted by the agent."
    ::= { eventEntry 7 }

--
logTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF LogEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A list of events that have been logged."
    ::= { event 2 }

logEntry OBJECT-TYPE
    SYNTAX     LogEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A set of data describing an event that has been
        logged.  For example, an instance of the logDescription
        object might be named logDescription.6.47"
    INDEX { logEventIndex, logIndex }
    ::= { logTable 1 }

LogEntry ::= SEQUENCE {
    logEventIndex           Integer32,
    logIndex                Integer32,
    logTime                 TimeTicks,
    logDescription          DisplayString
}

logEventIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The event entry that generated this log
        entry.  The log identified by a particular
        value of this index is associated with the same
        eventEntry as identified by the same value
        of eventIndex."
    ::= { logEntry 1 }

logIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..2147483647)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An index that uniquely identifies an entry
        in the log table amongst those generated by the
        same eventEntries.  These indexes are
        assigned beginning with 1 and increase by one
        with each new log entry.  The association
        between values of logIndex and logEntries
        is fixed for the lifetime of each logEntry.
        The agent may choose to delete the oldest
        instances of logEntry as required because of
        lack of memory.  It is an implementation-specific
        matter as to when this deletion may occur."
    ::= { logEntry 2 }

logTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The value of sysUpTime when this log entry was created."
    ::= { logEntry 3 }

logDescription OBJECT-TYPE
    SYNTAX     DisplayString (SIZE (0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "An implementation dependent description of the
        event that activated this log entry."
    ::= { logEntry 4 }

--  Remote Network Monitoring Traps

rmonEventsV2 OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION "Definition point for RMON notifications."
    ::= { rmon 0 }

risingAlarm NOTIFICATION-TYPE
    OBJECTS  { alarmIndex, alarmVariable, alarmSampleType,
               alarmValue, alarmRisingThreshold }
    STATUS   current
    DESCRIPTION
        "The SNMP trap that is generated when an alarm
        entry crosses its rising threshold and generates
        an event that is configured for sending SNMP
        traps."
    ::= { rmonEventsV2 1 }

fallingAlarm NOTIFICATION-TYPE
    OBJECTS { alarmIndex, alarmVariable, alarmSampleType,
              alarmValue, alarmFallingThreshold }
    STATUS    current
    DESCRIPTION
        "The SNMP trap that is generated when an alarm
        entry crosses its falling threshold and generates
        an event that is configured for sending SNMP
        traps."
    ::= { rmonEventsV2 2 }

-- Conformance information

rmonCompliances OBJECT IDENTIFIER ::= { rmonConformance 9 }
rmonGroups      OBJECT IDENTIFIER ::= { rmonConformance 10 }

-- Compliance Statements
rmonCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
        "The requirements for conformance to the RMON MIB. At least
        one of the groups in this module must be implemented to
        conform to the RMON MIB. Implementations of this MIB
        must also implement the system group of MIB-II [16] and the
        IF-MIB [17]."
    MODULE -- this module

      GROUP rmonEtherStatsGroup
          DESCRIPTION
              "The RMON Ethernet Statistics Group is optional."

      GROUP rmonHistoryControlGroup
          DESCRIPTION
              "The RMON History Control Group is optional."

      GROUP rmonEthernetHistoryGroup
          DESCRIPTION
              "The RMON Ethernet History Group is optional."

      GROUP rmonAlarmGroup
          DESCRIPTION
              "The RMON Alarm Group is optional."

      GROUP rmonHostGroup
          DESCRIPTION
              "The RMON Host Group is mandatory when the
              rmonHostTopNGroup is implemented."

      GROUP rmonHostTopNGroup
          DESCRIPTION
              "The RMON Host Top N Group is optional."

      GROUP rmonMatrixGroup
          DESCRIPTION
              "The RMON Matrix Group is optional."

      GROUP rmonFilterGroup
          DESCRIPTION
              "The RMON Filter Group is mandatory when the
              rmonPacketCaptureGroup is implemented."

      GROUP rmonPacketCaptureGroup
          DESCRIPTION
              "The RMON Packet Capture Group is optional."

      GROUP rmonEventGroup
          DESCRIPTION
              "The RMON Event Group is mandatory when the
              rmonAlarmGroup is implemented."
    ::= { rmonCompliances 1 }

    rmonEtherStatsGroup OBJECT-GROUP
        OBJECTS {
            etherStatsIndex, etherStatsDataSource,
            etherStatsDropEvents, etherStatsOctets, etherStatsPkts,
            etherStatsBroadcastPkts, etherStatsMulticastPkts,
            etherStatsCRCAlignErrors, etherStatsUndersizePkts,
            etherStatsOversizePkts, etherStatsFragments,
            etherStatsJabbers, etherStatsCollisions,
            etherStatsPkts64Octets, etherStatsPkts65to127Octets,
            etherStatsPkts128to255Octets,
            etherStatsPkts256to511Octets,
            etherStatsPkts512to1023Octets,
            etherStatsPkts1024to1518Octets,
            etherStatsOwner, etherStatsStatus
        }
        STATUS current
        DESCRIPTION
            "The RMON Ethernet Statistics Group."
        ::= { rmonGroups 1 }

    rmonHistoryControlGroup OBJECT-GROUP
        OBJECTS {
            historyControlIndex, historyControlDataSource,
            historyControlBucketsRequested,
            historyControlBucketsGranted, historyControlInterval,
            historyControlOwner, historyControlStatus
        }
        STATUS current
        DESCRIPTION
            "The RMON History Control Group."
        ::= { rmonGroups 2 }

    rmonEthernetHistoryGroup OBJECT-GROUP
        OBJECTS {
            etherHistoryIndex, etherHistorySampleIndex,
            etherHistoryIntervalStart, etherHistoryDropEvents,
            etherHistoryOctets, etherHistoryPkts,
            etherHistoryBroadcastPkts, etherHistoryMulticastPkts,
            etherHistoryCRCAlignErrors, etherHistoryUndersizePkts,
            etherHistoryOversizePkts, etherHistoryFragments,
            etherHistoryJabbers, etherHistoryCollisions,
            etherHistoryUtilization
        }
        STATUS current
        DESCRIPTION
            "The RMON Ethernet History Group."
        ::= { rmonGroups 3 }

    rmonAlarmGroup OBJECT-GROUP
        OBJECTS {
            alarmIndex, alarmInterval, alarmVariable,
            alarmSampleType, alarmValue, alarmStartupAlarm,
            alarmRisingThreshold, alarmFallingThreshold,
            alarmRisingEventIndex, alarmFallingEventIndex,
            alarmOwner, alarmStatus
        }
        STATUS current
        DESCRIPTION
            "The RMON Alarm Group."
        ::= { rmonGroups 4 }

    rmonHostGroup OBJECT-GROUP
        OBJECTS {
            hostControlIndex, hostControlDataSource,
            hostControlTableSize, hostControlLastDeleteTime,
            hostControlOwner, hostControlStatus,
            hostAddress, hostCreationOrder, hostIndex,
            hostInPkts, hostOutPkts, hostInOctets,
            hostOutOctets, hostOutErrors, hostOutBroadcastPkts,
            hostOutMulticastPkts, hostTimeAddress,
            hostTimeCreationOrder, hostTimeIndex,
            hostTimeInPkts, hostTimeOutPkts, hostTimeInOctets,
            hostTimeOutOctets, hostTimeOutErrors,
            hostTimeOutBroadcastPkts, hostTimeOutMulticastPkts
        }
        STATUS current
        DESCRIPTION
            "The RMON Host Group."
        ::= { rmonGroups 5 }

    rmonHostTopNGroup OBJECT-GROUP
        OBJECTS {
            hostTopNControlIndex, hostTopNHostIndex,
            hostTopNRateBase, hostTopNTimeRemaining,
            hostTopNDuration, hostTopNRequestedSize,
            hostTopNGrantedSize, hostTopNStartTime,
            hostTopNOwner, hostTopNStatus,
            hostTopNReport, hostTopNIndex,
            hostTopNAddress, hostTopNRate
        }
        STATUS current
        DESCRIPTION
            "The RMON Host Top 'N' Group."
        ::= { rmonGroups 6 }

    rmonMatrixGroup OBJECT-GROUP
        OBJECTS {
            matrixControlIndex, matrixControlDataSource,
            matrixControlTableSize, matrixControlLastDeleteTime,
            matrixControlOwner, matrixControlStatus,
            matrixSDSourceAddress, matrixSDDestAddress,
            matrixSDIndex, matrixSDPkts,
            matrixSDOctets, matrixSDErrors,
            matrixDSSourceAddress, matrixDSDestAddress,
            matrixDSIndex, matrixDSPkts,
            matrixDSOctets, matrixDSErrors
        }
        STATUS current
        DESCRIPTION
            "The RMON Matrix Group."
        ::= { rmonGroups 7 }

    rmonFilterGroup OBJECT-GROUP
        OBJECTS {

            filterIndex, filterChannelIndex, filterPktDataOffset,
            filterPktData, filterPktDataMask,
            filterPktDataNotMask, filterPktStatus,
            filterPktStatusMask, filterPktStatusNotMask,
            filterOwner, filterStatus,
            channelIndex, channelIfIndex, channelAcceptType,
            channelDataControl, channelTurnOnEventIndex,
            channelTurnOffEventIndex, channelEventIndex,
            channelEventStatus, channelMatches,
            channelDescription, channelOwner, channelStatus
        }
        STATUS current
        DESCRIPTION
            "The RMON Filter Group."
        ::= { rmonGroups 8 }

    rmonPacketCaptureGroup OBJECT-GROUP
        OBJECTS {
            bufferControlIndex, bufferControlChannelIndex,
            bufferControlFullStatus, bufferControlFullAction,
            bufferControlCaptureSliceSize,
            bufferControlDownloadSliceSize,
            bufferControlDownloadOffset,
            bufferControlMaxOctetsRequested,
            bufferControlMaxOctetsGranted,
            bufferControlCapturedPackets,
            bufferControlTurnOnTime,
            bufferControlOwner, bufferControlStatus,
            captureBufferControlIndex, captureBufferIndex,
            captureBufferPacketID, captureBufferPacketData,
            captureBufferPacketLength, captureBufferPacketTime,
            captureBufferPacketStatus
        }
        STATUS current
        DESCRIPTION
            "The RMON Packet Capture Group."
        ::= { rmonGroups 9 }

    rmonEventGroup OBJECT-GROUP
        OBJECTS {
            eventIndex, eventDescription, eventType,
            eventCommunity, eventLastTimeSent,
            eventOwner, eventStatus,
            logEventIndex, logIndex, logTime,
            logDescription
        }
        STATUS current
        DESCRIPTION
            "The RMON Event Group."
        ::= { rmonGroups 10 }

    rmonNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS { risingAlarm, fallingAlarm }
        STATUS        current
        DESCRIPTION
            "The RMON Notification Group."
        ::= { rmonGroups 11 }
END