diff options
author | Aman306 <45781773+Aman306@users.noreply.github.com> | 2020-10-28 23:36:09 +0530 |
---|---|---|
committer | GitHub <noreply@github.com> | 2020-10-28 14:06:09 -0400 |
commit | f99d4f96b00a9cfec1c721d364cbfd728674e5dc (patch) | |
tree | 22ec9e84009de46348b3df681007ec1f94de51f1 /cloudinit | |
parent | 29f0d136e24826a9b1c2c541755c64c4e51d5847 (diff) | |
download | vyos-cloud-init-f99d4f96b00a9cfec1c721d364cbfd728674e5dc.tar.gz vyos-cloud-init-f99d4f96b00a9cfec1c721d364cbfd728674e5dc.zip |
Add config modules for controlling IBM PowerVM RMC. (#584)
Reliable Scalable Cluster Technology (RSCT) is a set of software
components that together provide a comprehensive clustering
environment(RAS features) for IBM PowerVM based virtual machines. RSCT
includes the Resource Monitoring and Control (RMC) subsystem. RMC is a
generalized framework used for managing, monitoring, and manipulating
resources. RMC runs as a daemon process on individual machines and needs
creation of unique node id and restarts during VM boot.
LP: #1895979
Co-authored-by: Scott Moser <smoser@brickies.net>
Diffstat (limited to 'cloudinit')
-rw-r--r-- | cloudinit/config/cc_refresh_rmc_and_interface.py | 159 | ||||
-rw-r--r-- | cloudinit/config/cc_reset_rmc.py | 143 |
2 files changed, 302 insertions, 0 deletions
diff --git a/cloudinit/config/cc_refresh_rmc_and_interface.py b/cloudinit/config/cc_refresh_rmc_and_interface.py new file mode 100644 index 00000000..146758ad --- /dev/null +++ b/cloudinit/config/cc_refresh_rmc_and_interface.py @@ -0,0 +1,159 @@ +# (c) Copyright IBM Corp. 2020 All Rights Reserved +# +# Author: Aman Kumar Sinha <amansi26@in.ibm.com> +# +# This file is part of cloud-init. See LICENSE file for license information. + +""" +Refresh IPv6 interface and RMC +------------------------------ +**Summary:** Ensure Network Manager is not managing IPv6 interface + +This module is IBM PowerVM Hypervisor specific + +Reliable Scalable Cluster Technology (RSCT) is a set of software components +that together provide a comprehensive clustering environment(RAS features) +for IBM PowerVM based virtual machines. RSCT includes the Resource +Monitoring and Control (RMC) subsystem. RMC is a generalized framework used +for managing, monitoring, and manipulating resources. RMC runs as a daemon +process on individual machines and needs creation of unique node id and +restarts during VM boot. +More details refer +https://www.ibm.com/support/knowledgecenter/en/SGVKBA_3.2/admin/bl503_ovrv.htm + +This module handles +- Refreshing RMC +- Disabling NetworkManager from handling IPv6 interface, as IPv6 interface + is used for communication between RMC daemon and PowerVM hypervisor. + +**Internal name:** ``cc_refresh_rmc_and_interface`` + +**Module frequency:** per always + +**Supported distros:** RHEL + +""" + +from cloudinit import log as logging +from cloudinit.settings import PER_ALWAYS +from cloudinit import util +from cloudinit import subp +from cloudinit import netinfo + +import errno + +frequency = PER_ALWAYS + +LOG = logging.getLogger(__name__) +# Ensure that /opt/rsct/bin has been added to standard PATH of the +# distro. The symlink to rmcctrl is /usr/sbin/rsct/bin/rmcctrl . +RMCCTRL = 'rmcctrl' + + +def handle(name, _cfg, _cloud, _log, _args): + if not subp.which(RMCCTRL): + LOG.debug("No '%s' in path, disabled", RMCCTRL) + return + + LOG.debug( + 'Making the IPv6 up explicitly. ' + 'Ensuring IPv6 interface is not being handled by NetworkManager ' + 'and it is restarted to re-establish the communication with ' + 'the hypervisor') + + ifaces = find_ipv6_ifaces() + + # Setting NM_CONTROLLED=no for IPv6 interface + # making it down and up + + if len(ifaces) == 0: + LOG.debug("Did not find any interfaces with ipv6 addresses.") + else: + for iface in ifaces: + refresh_ipv6(iface) + disable_ipv6(sysconfig_path(iface)) + restart_network_manager() + + +def find_ipv6_ifaces(): + info = netinfo.netdev_info() + ifaces = [] + for iface, data in info.items(): + if iface == "lo": + LOG.debug('Skipping localhost interface') + if len(data.get("ipv4", [])) != 0: + # skip this interface, as it has ipv4 addrs + continue + ifaces.append(iface) + return ifaces + + +def refresh_ipv6(interface): + # IPv6 interface is explicitly brought up, subsequent to which the + # RMC services are restarted to re-establish the communication with + # the hypervisor. + subp.subp(['ip', 'link', 'set', interface, 'down']) + subp.subp(['ip', 'link', 'set', interface, 'up']) + + +def sysconfig_path(iface): + return '/etc/sysconfig/network-scripts/ifcfg-' + iface + + +def restart_network_manager(): + subp.subp(['systemctl', 'restart', 'NetworkManager']) + + +def disable_ipv6(iface_file): + # Ensuring that the communication b/w the hypervisor and VM is not + # interrupted due to NetworkManager. For this purpose, as part of + # this function, the NM_CONTROLLED is explicitly set to No for IPV6 + # interface and NetworkManager is restarted. + try: + contents = util.load_file(iface_file) + except IOError as e: + if e.errno == errno.ENOENT: + LOG.debug("IPv6 interface file %s does not exist\n", + iface_file) + else: + raise e + + if 'IPV6INIT' not in contents: + LOG.debug("Interface file %s did not have IPV6INIT", iface_file) + return + + LOG.debug("Editing interface file %s ", iface_file) + + # Dropping any NM_CONTROLLED or IPV6 lines from IPv6 interface file. + lines = contents.splitlines() + lines = [line for line in lines if not search(line)] + lines.append("NM_CONTROLLED=no") + + with open(iface_file, "w") as fp: + fp.write("\n".join(lines) + "\n") + + +def search(contents): + # Search for any NM_CONTROLLED or IPV6 lines in IPv6 interface file. + return( + contents.startswith("IPV6ADDR") or + contents.startswith("IPADDR6") or + contents.startswith("IPV6INIT") or + contents.startswith("NM_CONTROLLED")) + + +def refresh_rmc(): + # To make a healthy connection between RMC daemon and hypervisor we + # refresh RMC. With refreshing RMC we are ensuring that making IPv6 + # down and up shouldn't impact communication between RMC daemon and + # hypervisor. + # -z : stop Resource Monitoring & Control subsystem and all resource + # managers, but the command does not return control to the user + # until the subsystem and all resource managers are stopped. + # -s : start Resource Monitoring & Control subsystem. + try: + subp.subp([RMCCTRL, '-z']) + subp.subp([RMCCTRL, '-s']) + except Exception: + util.logexc(LOG, 'Failed to refresh the RMC subsystem.') + raise diff --git a/cloudinit/config/cc_reset_rmc.py b/cloudinit/config/cc_reset_rmc.py new file mode 100644 index 00000000..1cd72774 --- /dev/null +++ b/cloudinit/config/cc_reset_rmc.py @@ -0,0 +1,143 @@ +# (c) Copyright IBM Corp. 2020 All Rights Reserved +# +# Author: Aman Kumar Sinha <amansi26@in.ibm.com> +# +# This file is part of cloud-init. See LICENSE file for license information. + + +""" +Reset RMC +------------ +**Summary:** reset rsct node id + +Reset RMC module is IBM PowerVM Hypervisor specific + +Reliable Scalable Cluster Technology (RSCT) is a set of software components, +that together provide a comprehensive clustering environment (RAS features) +for IBM PowerVM based virtual machines. RSCT includes the Resource monitoring +and control (RMC) subsystem. RMC is a generalized framework used for managing, +monitoring, and manipulating resources. RMC runs as a daemon process on +individual machines and needs creation of unique node id and restarts +during VM boot. +More details refer +https://www.ibm.com/support/knowledgecenter/en/SGVKBA_3.2/admin/bl503_ovrv.htm + +This module handles +- creation of the unique RSCT node id to every instance/virtual machine + and ensure once set, it isn't changed subsequently by cloud-init. + In order to do so, it restarts RSCT service. + +Prerequisite of using this module is to install RSCT packages. + +**Internal name:** ``cc_reset_rmc`` + +**Module frequency:** per instance + +**Supported distros:** rhel, sles and ubuntu + +""" +import os + +from cloudinit import log as logging +from cloudinit.settings import PER_INSTANCE +from cloudinit import util +from cloudinit import subp + +frequency = PER_INSTANCE + +# RMCCTRL is expected to be in system PATH (/opt/rsct/bin) +# The symlink for RMCCTRL and RECFGCT are +# /usr/sbin/rsct/bin/rmcctrl and +# /usr/sbin/rsct/install/bin/recfgct respectively. +RSCT_PATH = '/opt/rsct/install/bin' +RMCCTRL = 'rmcctrl' +RECFGCT = 'recfgct' + +LOG = logging.getLogger(__name__) + +NODE_ID_FILE = '/etc/ct_node_id' + + +def handle(name, _cfg, cloud, _log, _args): + # Ensuring node id has to be generated only once during first boot + if cloud.datasource.platform_type == 'none': + LOG.debug('Skipping creation of new ct_node_id node') + return + + if not os.path.isdir(RSCT_PATH): + LOG.debug("module disabled, RSCT_PATH not present") + return + + orig_path = os.environ.get('PATH') + try: + add_path(orig_path) + reset_rmc() + finally: + if orig_path: + os.environ['PATH'] = orig_path + else: + del os.environ['PATH'] + + +def reconfigure_rsct_subsystems(): + # Reconfigure the RSCT subsystems, which includes removing all RSCT data + # under the /var/ct directory, generating a new node ID, and making it + # appear as if the RSCT components were just installed + try: + out = subp.subp([RECFGCT])[0] + LOG.debug(out.strip()) + return out + except subp.ProcessExecutionError: + util.logexc(LOG, 'Failed to reconfigure the RSCT subsystems.') + raise + + +def get_node_id(): + try: + fp = util.load_file(NODE_ID_FILE) + node_id = fp.split('\n')[0] + return node_id + except Exception: + util.logexc(LOG, 'Failed to get node ID from file %s.' % NODE_ID_FILE) + raise + + +def add_path(orig_path): + # Adding the RSCT_PATH to env standard path + # So thet cloud init automatically find and + # run RECFGCT to create new node_id. + suff = ":" + orig_path if orig_path else "" + os.environ['PATH'] = RSCT_PATH + suff + return os.environ['PATH'] + + +def rmcctrl(): + # Stop the RMC subsystem and all resource managers so that we can make + # some changes to it + try: + return subp.subp([RMCCTRL, '-z']) + except Exception: + util.logexc(LOG, 'Failed to stop the RMC subsystem.') + raise + + +def reset_rmc(): + LOG.debug('Attempting to reset RMC.') + + node_id_before = get_node_id() + LOG.debug('Node ID at beginning of module: %s', node_id_before) + + # Stop the RMC subsystem and all resource managers so that we can make + # some changes to it + rmcctrl() + reconfigure_rsct_subsystems() + + node_id_after = get_node_id() + LOG.debug('Node ID at end of module: %s', node_id_after) + + # Check if new node ID is generated or not + # by comparing old and new node ID + if node_id_after == node_id_before: + msg = 'New node ID did not get generated.' + LOG.error(msg) + raise Exception(msg) |